Once a code change request becomes a minor or CBHCC approved task, it transitions to a proposed change that follows the path outlined in the code development process.

This proposed change tracking database can be used by code change request proponents to follow the progress of proposed changes for a task linked to their code change request. Information in the database can be accessed using the filter option or toggle arrows to sort by:

  • ID number (the number assigned when a code development committee has started its work on the issue and created a proposed change form for potential publication),
  • title,
  • description,
  • code reference,
  • status (the progress of the proposed change through the system), and
  • code change request (the corresponding code change request number assigned when it was originally submitted by a proponent, see the code change request tracking database).

Please direct any questions related to code change requests to CBHCC code change request.

 

IDTitleDescriptionCode ReferenceStatusCode Change Requests
2275Determination of Compliance for Unmet Cooling Load Hours in Energy modelingRevise the NECB compliance requirement for unmet cooling load hours used to compare the proposed building and reference building energy models.NECB20 Div.B 8.4.1.2.--
2273Potable Water SystemsIntroduce requirements for domestic hot water systems to maintain intended temperatures, including provisions for minimum temperature. NPC20 Div.B 2.6.3.--
2272Provisions for concrete members reinforced with fibre-reinforced polymer to conform to CSA S806This proposed change adds provisions requiring building structural members reinforced with fibre-reinforced polymer to be designed in accordance with CSA S806.NBC20 Div.B 4.3.3.1.--
2269Updates the title of Note A-8.4.5.13.Improves the accuracy of the note titleNECB20 Div.B 8.4.Standing Codes Coordination Committee: Review
2026-06-09
NMCC on Climate Change Mitigation: Review — Editorial Revision/Errata (No Public Review)
2026-06-12
-
2268Thermal Bridge definition moved to Division AThe proposed changes moves the definition of thermal bridge from Division B to Division ANECB20 Div.A 1.4.1.2.,
NECB20 Div.B 3.1.1.4.
Standing Codes Coordination Committee: Review
2026-06-09
NMCC on Climate Change Mitigation: Review — Recommended for Public Review
2026-06-12
-
2267Ducts InsulationIncrease the minimum thermal resistance (RSI) for ducts.NBC20 Div.B 9.32.3.11.Energy Efficiency: Review
2026-06-04
NMCC on Climate Change Mitigation: Review — Recommended for Public Review
2026-06-04
-
2266Add Requirements for MURBs with Energy Storage Systems (ESS) in Part 9 of NBCThis proposed change introduces requirements to Part 9 of NBC to address the potential fire and life safety hazards associated with battery-based energy storage systems (ESS) in multi-unit residential buildings (MURBs).---
2265New Definitions Related to Operational GHG EmissionsThis proposed change moves the locally defined terms “annual operational GHG emissions” and “operational GHG emissions target” from Div. B to Div. A within the NECB and NBC.NECB20 Div.A 1.4.1.2.(1),
NBC20 Div.A 1.4.1.2.(1)
Standing Codes Coordination Committee: Review
2026-06-09
NMCC on Climate Change Mitigation: Review — Recommended for Public Review
2026-06-12
-
2263New Article on definitionsThis proposed change adds a new Article to NECB Part 10 on "Definitions", referencing Article 1.4.1.2 of Division A of the NECB for defined terms and aligning Part 10 with the other Parts of the Code.NECB20 Div.B 10.1.Standing Codes Coordination Committee: Review
2026-06-09
NMCC on Climate Change Mitigation: Review — Recommended for Public Review
2026-06-12
-
2262Addition of NFPA 105 for Inspection and Testing of Smoke DampersThis request is to add NFPA 105, “Standard for Smoke Door Assemblies and Other Opening Protectives,” as the test standard for smoke dampers and combination smoke/fire dampers in the National Fire Code (NFC).NFC20 Div.B 2.2.2.4.--
2261PT-Led Changes on EMTC - Fire Code Provisions (Consolidated)This proposed change consolidates the PT-led changes on EMTC (re: fire code) into a dedicated form, and updates the baseline 'existing provisions' to reflect the first printing of the 2025 edition of the National Fire Code (NFC); the 'rationale' section provided by the PT-led group is maintained.NFC20 Div.B 5.6.3.,
NFC20 Div.B 5.6.4.
TG/WG Development
2026-02-19
-
2260PT-Led Changes on EMTC - Building Code Provisions (Consolidated)This proposed change consolidates the PT-led changes on EMTC (re: building code) into a dedicated form, and updates the baseline 'existing provisions' to reflect the first printing of the 2025 edition of the National Building Code (NFC); the 'rationale' section provided by the PT-led group is maintained.NBC20 Div.B 3.1.3.1.(1),
NBC20 Div.B 3.1.3.1. Table ,
NBC20 Div.B 3.1.6.4.,
NBC20 Div.B 3.1.6.6.,
NBC20 Div.B 3.1.6.9.,
NBC20 Div.B 3.1.6.14.,
NBC20 Div.B 3.1.7.5.(1),
NBC20 Div.B 3.1.11.5.(4),
NBC20 Div.B 3.1.15.2.(5),
NBC20 Div.B 3.2.1.4.(1),
NBC20 Div.B 3.2.1.6.(1),
NBC20 Div.B 3.2.2.2.(1),
NBC20 Div.B 3.2.2.6.,
NBC20 Div.B 3.2.2.7.,
NBC20 Div.B 3.2.2.11.,
NBC20 Div.B 3.2.2.12.(1),
NBC20 Div.B 3.2.2.13.(1),
NBC20 Div.B 3.2.2.14.,
NBC20 Div.B 3.2.2.16.(1),
NBC20 Div.B 3.2.2.18.,
NBC20 Div.B 3.2.2.19.(1),
NBC20 Div.B 3.2.2.23.(1),
NBC20 Div.B 3.2.2.42.(1),
NBC20 Div.B 3.2.2.47.(1),
NBC20 Div.B 3.2.2.48.,
NBC20 Div.B 3.2.2.56.(1),
NBC20 Div.B 3.2.2.57.,
NBC20 Div.B 3.2.2.66.(1),
NBC20 Div.B 3.2.2.76.(1),
NBC20 Div.B 3.2.2.82.(1),
NBC20 Div.B 3.2.3.7.(2),
NBC20 Div.B 3.2.3.7. Table ,
NBC20 Div.B 3.2.3.9.(1),
NBC20 Div.B 3.2.5.12.(7),
NBC20 Div.B 3.2.6.1.(2),
NBC20 Div.B 3.3.3.7.(4)
TG/WG Development
2026-02-19
-
2259Replace the withdrawn existing reference for gypsum board application with a new standard that is already referenced in NBCThis request is to replace CSA A82.31-M, “Gypsum Board Application,” with ASTM C840, “Standard Specification for Application and Finishing of Gypsum Board,” as the standard for gypsum board application.NBC20 Div.B 3.1.5.14.(6),
NBC20 Div.B 9.10.9.2.(5),
NBC20 Div.B 9.10.12.4.(3),
NBC20 Div.B 9.10.14.5.(8),
NBC20 Div.B 9.10.15.5.(7),
NBC20 Div.B 9.10.15.5.(11),
NBC20 Div.B 9.29.5.1.(2),
NBC20 Div.B 9.10.3.1.
--
2257Carbon monoxide (CO) detectors installed in lieu of CO alarmsThis proposed change adds requirements for carbon monoxide detectors that are connected to a building fire alarm system in lieu of carbon monoxide alarmsNBC20 Div.B 6.9.3.,
NBC20 Div.B 9.32.3.9.
Standing Codes Coordination Committee: Review
2026-04-29
1286, 1288
2256Provisions for carbon monoxide detectors conforming to CAN/ULC 588 for ventilation of storage garagesThis proposed change requires carbon monoxide, nitrogen dioxide and other acceptable monitoring devices required by Sentence 6.3.1.3.(2) to conform to a National Standard of CanadaNBC20 Div.B 6.3.1.3.Standing Codes Coordination Committee: Review
2026-04-29
1287
2255Domestic Hot Water Temperature MaintenanceIntroduce design requirements for domestic hot water systems to maintain intended temperatures, including provisions for minimum temperature, recirculation performance, and measures to limit heat loss.---
2243HP-NPC20 Div.B 2.1.1.1.Standing Codes Coordination Committee: Review
2026-04-29
-
2242HP-NPC20 Div.B 2.1.1.1.Standing Codes Coordination Committee: Review
2026-04-29
-
2241HP-NPC20 Div.B 2.1.1.1.Standing Codes Coordination Committee: Review
2026-04-29
-
2240HP-NPC20 Div.B 2.1.1.1.Standing Codes Coordination Committee: Review
2026-04-29
-
2226Addition of ASTM C1278/C1278M-2024 to the NBCThe proposed changes add the standard ASTM C1278/C1278M, “Standard Specification for Fiber-Reinforced Gypsum Panel” to the NBC.NBC20 Div.B 5.9.1.1.,
NBC20 Div.B 9.29.5.2.(1)
Standing Codes Coordination Committee: Review
2026-04-29
1834
2225Addition of CAN/ULC-S743.1 and CAN/ULC-S743.2 to the NBCThe proposed changes add the standards CAN/ULC-S743.1:2020 (R2025), “Standard for Thermal Insulation – Low Pressure Applied Two Component Spray Polyurethane foam, Part 1: Material Specification” and CAN/ULC-S743.2:2021, “Standard for Thermal Insulation – Low Pressure Applied Two Component Spray Polyurethane Foam, Part 2: Installation” to the NBC.NBC20 Div.B 5.9.1.1.,
NBC20 Div.B 9.25.2.2.(1),
NBC20 Div.B 9.25.2.5.(1),
NBC20 Div.B 9.36.2.4.(1)
Standing Codes Coordination Committee: Review
2026-04-29
1656, 1657
2222Fire-Resistance Rating of File Storage Room in Detention OccupanciesThis proposed change sets a minimum fire-resistance rating for rooms used to store files, evident and firearms in detention occupancies.NBC20 Div.B 3.3.3.5.Draft
2026-04-08
2130
2221Updates to Referenced Documents-NBC20 Div.B 1.3.1.2.,
NFC20 Div.B 1.3.1.2.,
NPC20 Div.B 1.3.1.2.,
NECB20 Div.B 1.3.1.2.
Standing Codes Coordination Committee: Review
2026-04-29
-
2220Energy intensity-based targets for retail and warehouseThis proposed change establishes intensity-based energy targets for retail and warehouse archetypes.NECB20 Div.B 8.4.4.Standing Codes Coordination Committee: Review
2026-06-09
-
2219Section 10.7 Alteration of Existing Plumbing SystemsEstablish requirements for alterations to existing plumbing systems and criteria for determining the extent of alterations and applicable provisions.NBC20 Div.B 10--
2217Scope and ApplicationThis proposed change defines Scope and application of a new Section establishing specific requirements to address the unique characteristics of tiny houses.NBC20 Div.B 9.38.--
2216Roof load transfer to braced wall panelsThe proposed change addresses the transfer of loads from roof rafters or roof trusses to braced wall panels.NBC20 Div.B 9.23.13.5.--
2209Cane detectable barricades on construction sitesThis PCF clarifies the need for cane detectable barricades at construction sitesNBC20 Div.B 8.2.3.3.NMCC on Accessibility: Draft
2026-01-28
-
2207Clarification on the Use of the Term "Fire Watch" Outside Section 5.2. Hot WorkThis proposed change clarifies the use of the term "fire watch" in provisions outside Section 5.2. of Division B of the NFC.NFC20 Div.B 2.8.2.11.,
NFC20 Div.B 2.9.3.4.,
NFC20 Div.B 2.13.2.3.,
NFC20 Div.B 6.1.1.4.(1)
NMCC on Fire and Life Safety: TG/WG Development
2026-01-23
-
2206Welding and Cutting Requirements for Farm BuildingsThis proposed change introduces the requirements of Sentence 3.3.1.26.(1) of Division B of the NBC into Sentence 2.2.8.4.(1).NBC20 Div.B 2.2.8.4.NMCC on Fire and Life Safety: TG/WG Development
2026-01-22
-
2205New Section 9.37. on Operational GHG EmissionsMoves Subsections 9.36.15. and 9.36.16. to a new Section to separate requirements for operational GHG emissions from energy efficiencyNBC20 Div.B 9.36.1.3.NMCC on Climate Change Mitigation: Draft
2026-01-20
NMCC on Climate Change Mitigation: Review — Recommended for Public Review
2026-02-11
Standing Codes Coordination Committee: Review
2026-04-29
-
2204Power door operators when fire alarm is activatedThe proposed change clarifies how power door operators should be disconnected when fire alarms are activated. NBC20 Div.B 3.4.6.16.NMCC on Accessibility: Draft
2026-01-20
1812
2203Minimum number of exits for spaces with doors directly to the exteriorThis proposed change clarifies the number of exits that is required for suites, service rooms, and other spaces at ground level with direct access to the exterior. NBC20 Div.B 3.4.2.1.Draft
2026-01-20
2090
2202Visible fire/smoke alarm signals in additional locationsThis PCF proposes to require visible signals for fire alarm systems and smoke alarms in more locations so that people with low/no hearing can get the same information as anyone else. NBC20 Div.B 3.2.4.19.,
NBC20 Div.B 3.2.4.20.,
NBC20 Div.B 9.10.19.
NMCC on Accessibility: Draft
2026-01-07
2252
2199New Abbreviations Related to Heating, Ventilating and Air-conditioning Systems - OtherThis proposed change updates the list of symbols and abbreviations in the NBC and NECB.NECB20 Div.A 1.4.2.1.(1)--
2197Clarification - Ramps in "cold climates"This PCF clarifies a note about difficulty of navigating ramps in "cold climates" to specify this means wet and icy conditions. NBC20 Div.B 3.8.3.5.NMCC on Accessibility: TG/WG Development
2025-11-20
NMCC on Accessibility: Review
2026-01-09
-
2196Defined TermsThis proposed change introduce new defined terms in the NECB NECB20 Div.A 1.4.1.2.--
2195Hot Service Water Flow RatesReferences NPC for requirements related to maximum water flow rates and automatic shut‑off devices, ensuring consistency between the NECB and NPC.NECB20 Div.B 6.2.6.Standing Codes Coordination Committee: Review
2026-04-29
NMCC on Climate Change Mitigation: Review — Recommended for Public Review
2026-06-12
-
2192Removing CSA B651 path from 3.8.3.1. and update to CSA B651-23-NBC20 Div.B 3.8.3.1.NMCC on Accessibility: TG/WG Development
2025-11-20
NMCC on Accessibility: Review — Recommended for Public Review
2026-04-09
Standing Codes Coordination Committee: Review
2026-04-29
2149
2191Ceiling lifts in accessible change spaces-NBC20 Div.B 3.8.NMCC on Accessibility: TG/WG Development
2026-04-30
-
2190Signage for accessible change space location-NBC20 Div.B 3.8.NMCC on Accessibility: TG/WG Development
2026-05-01
-
2189Option for bilateral toilet in universal washrooms (fold down grab bars)-NBC20 Div.B 3.8.NMCC on Accessibility: TG/WG Development
2026-04-30
-
2188Emergency call buttons in universal washrooms-NBC20 Div.B 3.8.NMCC on Accessibility: TG/WG Development
2026-04-30
-
2187Accessible change spaces - table properties-NBC20 Div.B 3.8.NMCC on Accessibility: TG/WG Development
2026-04-30
-
2186Width of a barrier-free path of travel over long intervals-NBC20 Div.B 3.8.NMCC on Accessibility: Draft
2026-01-13
-
2185Increase width of barrier-free path of travel-NBC20 Div.B 3.8.NMCC on Accessibility: Draft
2026-01-13
-
2183Updates compliance for Subsection 9.36.16.Adds tier 2 prescriptive requirements as a compliance option in Sentence 9.36.16.3.(2)NBC20 Div.B 9.36.Standing Codes Coordination Committee: Review
2026-06-09
-
2182Update Modelling Rules for Heat PumpsUpdates modelling rules for heat pumps for reference house and tier 1; adds percent heat loss reduction requirement for tier 1NBC20 Div.B 9.36.5.15.(2),
NBC20 Div.B 9.36.5.16.(1),
NBC20 Div.B 9.36.7.2. Table ,
NBC20 Div.B 9.36.7.3.
Standing Codes Coordination Committee: Review
2026-04-29
NMCC on Climate Change Mitigation: Review — Recommended for Public Review
2026-06-12
-
2181Removes base code as a energy performance compliance pathRemoves base code as a compliance path and requires code users to instead comply with energy tier 1NBC20 Div.B 9.36.1.3.(1)Standing Codes Coordination Committee: Review
2026-04-29
NMCC on Climate Change Mitigation: Review — Recommended for Public Review
2026-06-12
-
2179Designated Hot Work AreaThis proposed change refines the requirements applicable to a designated area where hot work could be performed without a permit.NBC20 Div.B 3.3.NMCC on Fire and Life Safety: Draft
2025-12-16
-
2178Add Requirements for Energy Storage Systems (ESS) for Part 3 BuildingsThis proposed change introduces requirements to address the potential fire and life safety hazards associated with battery-based energy storage systems (ESS) installed in Part 3 Buildings.NBC20 Div.B 3.6.2.--
2177New Defined Term of Energy Storage Systems (ESS)This proposed change introduces a new defined term of Energy Storage Systems (ESS) to NBCNBC20 Div.A 1.4.1.2.(1)--
2175Fire Watch (Personnel) and Hot Work Monitoring (Activity)This proposed change defines the required activities for fire monitoring hot works and duties of the fire watch.NFC20 Div.B 5.2.NMCC on Fire and Life Safety: Draft
2025-12-08
-
2174Design of Potable Water Systems per Water Demand Calculator MethodThis proposed change includes a reference to the IAPMO Water Demand Calculator as one of potable water system design guides.NPC20 Div.B 2.6.3.1.(2)Standing Codes Coordination Committee: Review
2026-04-29
2052
2173Introducing a New Standard CAN/ULC for Plenum RequirementsAdd CAN/ULC S-142. "Standard Method of Fire Test for Heat and Visible Smoke Release for Discrete Products", as a test method for Discrete Stand-Alone Non-Continuous Products Installed in Concealed Spaces Used as Plenums.NBC20 Div.B 3.6.4.3.(1)Standing Codes Coordination Committee: Review
2026-04-29
1793
2172Intensity-based compliance for operational GHG emissions-NBC20 Div.B 9.36.Standing Codes Coordination Committee: Review
2026-04-29
-
2170Intensity-based compliance for operational GHG emissions and energy efficiencyThis proposed change introduces an intensity-based approach in the NECB for complying with operational GHG emissions requirements. It also establishes intensity-based energy targets for retail and warehouse archetypes.NECB20 Div.B 8.4.4.,
NECB20 Div.B 11
Standing Codes Coordination Committee: Review
2026-06-09
-
2168Minimum number of exits for spaces with doors directly to the exteriorThis proposed change clarifies the number of exits that is required for suites, service rooms, and other spaces at ground level with direct access to the exterior. NBC20 Div.B 3.4.2.1.Draft
2025-11-13
2090
2167Garages with EV charging stationsThis proposed change introduce requirements for parking garages with EV charging stations.NBC20 Div.B 3.2.4.1.(1)-2167
2166Defined Term of EVThis proposed change introduces defined term "Electric Vehicle (EV)" to Division A of NBC.NBC20 Div.A 1.4.1.2.(1)-2167
2162Add Requirements for Houses with Energy Storage Systems (ESS) in Part 9 of NBCThis proposed change introduces requirements to Part 9 of NBC to address the potential fire and life safety hazards associated with battery-based energy storage systems (ESS) in houses.-NMCC on Fire and Life Safety: Draft
2025-11-04
2057
2161Standard for Installation of Fuel Supplies for Heating Equipment and Internal Combustion EnginesThis proposed change adds reference to CAN/CSA B138.1/B138.2-17 (R2022), "Portable Oil Burning Equipment – Packaged Equipment Requirements/Installation Requirements" as an option for installation of heating equipment and internal combustion engines.NFC20 Div.B 5.6.1.10.(1)Standing Codes Coordination Committee: Review
2026-04-29
-
2160Active Side Wall Radon StackThis proposed change adds requirements for radon mitigation by use of an optional active side wall radon stack in dwelling units and home-type care occupancies that have a wall, roof or floor assembly in contact with the ground.NBC20 Div.B 9.13.4.Standing Codes Coordination Committee: Review
2025-11-21
NMCC on Indoor Environment: Review — Recommended for Public Review
2026-02-18
-
2157Moving the Reference to CSA A277, "Procedure for certification of prefabricated buildings, modules, and panels," from a Division A Note to a Division C ProvisionThis proposed change permits a certificate to CSA A277, "Procedure for certification of prefabricated buildings, modules, and panels," to be considered as third-party Code compliance approval to facilitate the approval of factory-constructed buildings, modules and panels. NBC20 Div.A 1.1.1.1.,
NBC20 Div.C 2.2.7.5.
Standing Codes Coordination Committee: Review
2025-11-21
NMCC on Housing Supply: Review — Recommended for Public Review
2025-12-11
CBHCC: Pre-Public Review — Proceed
2026-01-22
-
2154INTERNAL ONLY - USED TO EDITORIALLY COMBINE PCF 1475 AND PCF 2048-NBC20 Div.B 9.4.1.1.,
NBC20 Div.B 9.4.2.,
NBC20 Div.B 9.6.1.3.,
NBC20 Div.B 9.20.1.,
NBC20 Div.B 9.23.1.1.,
NBC20 Div.B 9.23.2.,
NBC20 Div.B 9.23.3.1.,
NBC20 Div.B 9.23.3.4.,
NBC20 Div.B 9.23.3.5.,
NBC20 Div.B 9.23.6.1.,
NBC20 Div.B 9.23.11.4.,
NBC20 Div.B 9.23.13.,
NBC20 Div.B 9.23.16.1.,
NBC20 Div.B 9.23.16.5.,
NBC20 Div.B 9.27.5.4.(2),
NBC20 Div.B 9.27.5.4. Table B,
NBC20 Div.B 9.31.6.2.(3),
NBC20 Div.B 9.33.4.7.(2)
--
2153Classification of Additional Water Miscible Liquid MixturesThis proposed change provides classification for additional four water-miscible liquid mixtures.NFC20 Div.B 4.1.2.2.Draft
2025-08-20
NMCC on Fire and Life Safety: TG/WG Development
2026-01-20
NMCC on Fire and Life Safety: Review — Recommended for Public Review
2026-02-02
Standing Codes Coordination Committee: Review
2026-04-29
-
2151NBC and NECB 2025 Editorial ChangesThis PCF collects all editorial changes received during the 2025 Code cycle from TAs via email and introduces attribution tables for new Parts.NBC20 Div.B 2.2.1.8.(3),
NBC20 Div.B 3.4.6.8.(8),
NBC20 Div.B 6.3.1.4.(1),
NBC20 Div.B 6.9.2.,
NBC20 Div.B 9.36.1.1.(1),
NBC20 Div.B 9.36.1.3.,
NBC20 Div.B 9.36.2.7.,
NBC20 Div.B 10.1.,
NECB20 Div.B 11,
NECB20 Div.B 13
--
2148BERS IT - TEST FILETest test test test test test test test test test test test test test test test test test test test test test test test test test test test test test test test test test test test test testNBC20 Div.B 3.2.2.2.(1),
NBC20 Div.B 3.2.2.1.(1),
NBC20 Div.B 9.36.11.
NMCC on Performance-Based Solutions: Draft
2025-11-01
-
2147Door hardware in door clear width considerationsClarification of explanatory note on clear width of doorways in relation to door hardwareNBC20 Div.B 3.8.3.6.(2)NMCC on Accessibility: TG/WG Development
2026-05-01
2171
2146Door hardware in door clear width considerationsThis PCF clarifies wording around door closers and exit devices and how they are considered for the clear width of doorwaysNBC20 Div.B 3.8.3.6.(2)--
2145Update Classification of Water Miscible Liquid MixturesThis proposed change updates the testing method and the classification of water miscible liquid mixtures (WMLMs) in NFC.NFC20 Div.B 4.1.2.1.,
NFC20 Div.B 4.1.2.2.
NMCC on Fire and Life Safety: Draft
2025-07-17
NMCC on Fire and Life Safety: TG/WG Development
2026-01-20
NMCC on Fire and Life Safety: Review — Recommended for Public Review
2026-02-02
Standing Codes Coordination Committee: Review
2026-04-29
-
2141Requirements for Circuit Venting in NPC This proposed change includes consistent fixture units to be referenced for stack within Article 2.5.3.1. and Figure A-2.5.3.1.-E Example 2NPC20 Div.B 2.5.3.1.-2134
2140Requirements for the Upper Design Supply Temperature of Hydronic Heating SystemsThis proposed change includes requirements for an upper limit to the allowable design supply temperature of hydronic heating systems in NECB Articles 5.2.1.1., 5.4.1.2. and 8.4.4.9. NECB20 Div.B 5.2.1.1.,
NECB20 Div.B 5.4.1.2.,
NECB20 Div.B 8.4.4.9.
-2128
2138Requirements for Floor Drains in NBC Part 3 and 9 BuildingsThis proposed change includes consistent requirements for floor drains, to be provided in Sentences 3.7.2.6.(1) and proposed (2) to (4), proposed Note A-3.7.2.6.(4), Table 3.10.1.1., Sentences 9.31.4.3.(1) and 9.35.2.2.(1), and Note A-9.35.2.2.(1), and Article 9.37.1.1. of Division B of NBCNBC20 Div.B 3.7.2.6.,
NBC20 Div.B 9.31.4.3.,
NBC20 Div.B 9.35.2.2.,
NBC20 Div.B 9.37.1.1.
-2066
2137 Installation of a Backwater Valve for Plumbing Fixtures Located Below the Upstream Sanitary ManholeThis proposed change clarifies requirements for the installation of a backwater valve to protect plumbing fixtures from backflow.NPC20 Div.B 2.4.6.4.TG/WG Development
2025-11-03
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Deferred
2026-01-22
TG/WG Development
2026-02-04
CBHCC: Pre-Public Review — Proceed
2026-02-23
817
2133Requirements for Installation of Drainage Piping Without DepressionsThe proposed changes introduce requirements for drainage piping to be installed without depressions where accumulation may collect.NPC20 Div.B 2.4.1.1.Standing Codes Coordination Committee: Review
2026-04-29
1942
2132Requirements for Maximum Cleanout Distance Interval in Vertical Pipes of a Drainage SystemThis proposed change includes requirements for cleanout and access at maximum distance interval for vertical sink wastes.NPC20 Div.B 2.4.7.2.Standing Codes Coordination Committee: Review
2026-04-29
1941
2131Requirements for the Minimum Number of Baffles in a Grease InterceptorThis proposed change includes requirements for the minimum number of baffles in a grease interceptor in Article 2.5.5.2.NPC20 Div.B 2.5.5.2.Draft
2026-03-17
-
2130Connections to Sanitary Drainage Systems with different Devices Clarify termination requirements for device connections to sanitary drainage systems, including air gaps for indirect drainage to prevent backflow and protect potable water.NPC20 Div.B 2.4.2.1.(1)TG/WG Development
2026-02-17
Standing Codes Coordination Committee: Review
2026-04-29
1821
2129Clarification of numbers of stalls and urinals for people with limited mobilityThis PCF clarifies how to interpret the requirements for numbers of required stalls for people with limited mobility. NBC20 Div.B 3.8.2.8.,
NBC20 Div.B 3.7.2.2.
NMCC on Accessibility: TG/WG Development
2025-09-16
NMCC on Accessibility: TG/WG Development
2025-11-20
-
2128Separation from Other Dangerous GoodsThis proposed change update the separation table for the storage of dangerous goods and controlled products.NFC20 Div.B 3.2.7.6.NMCC on Fire and Life Safety: TG/WG Development
2025-08-13
-
2127Accessible change spaces in B3 occupancies (care occupancy)This proposed change requires at least one accessible change space in care occupancy buildings. These can be part of universal washrooms. NBC20 Div.B 3.8.2.8.NMCC on Accessibility: TG/WG Development
2026-05-01
1757
2125Accessible fitting roomsThis PCF proposes to require that where fitting rooms are provided (ex: in a clothing store), at least one should be accessible. NBC20 Div.B 3.8.2.3.NMCC on Accessibility: TG/WG Development
2026-05-01
1687
2123Removal of the term "ambulatory"The PCF proposes to remove the reference to "ambulatory" in describing the building's occupants, as it is not a defined and set state of being. NBC20 Div.B 3.1.2.5.,
NBC20 Div.B 3.3.1.7.,
NBC20 Div.B 9.10.2.2.
Draft
2025-01-24
815, 2220
2122Clarifying what "Pedestrian Entrance" MeansThis proposed change explains what a "pedestrian entrance" means for accessibility purposes.NBC20 Div.B 3.8.2.2.Draft
2025-01-24
1752
2120Updating the Defined Term "Barrier-free"This proposed change revises the definition of the term "barrier-free", the associated objectives and functional statements to align with current legislation, standards and other codes. NBC20 Div.A 1.4.1.2.,
NBC20 Div.A 2.2.1.1.,
NBC20 Div.A 3.2.1.1.(1)
Draft
2025-01-17
1527, 2233, 2238, 2244, 2235
2116Introducing a New Standard ANSI/CAN/UL/ULC 2152 for Special Purpose Nonmetalic ContainersThis request is to add ANSI/CAN/UL/ULC 2152, “Safety for Special Purpose Nonmetallic Containers and Tanks for Specific Combustible or Noncombustible Liquids” standard to allow the use of special purpose nonmetalic containers and tanks for combustible or noncombustible liquids.NFC20 Div.B 4.3.1.2.(1)Standing Codes Coordination Committee: Review
2026-04-29
1646
2112Introducing a New Standard ANSI/CAN/UL/ULC 1369:2020 for Aboveground PipingAdd Standard ANSI/CAN/UL/ULC 1369:2020, "Aboveground Piping for Flammable and Combustible Liquids," to ensure conformance of metallic and nonmetallic piping systems used in aboveground installations.NFC20 Div.B 4.5.2.1.(3)TG/WG Development
2026-02-09
Standing Codes Coordination Committee: Review
2026-04-29
1541
2109Fan Motor Power Threshold for the Application of Prescriptive RequirementsThis proposed change lowers the threshold for total fan motor power for the application of prescriptive requirements.NECB20 Div.B 5.2.3.1.Energy Efficiency: Review — Recommended for Public Review
2024-12-18
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
1437
2108Revision of Attributions and Intent Statements in Division B of NBCRevise attributions and intent statements in Division B of the NBC following an assessment of the provisions, intents, relevant objectives and functional statements.NBC20 Div.B 2.2.1.14.(1),
NBC20 Div.B 2.2.1.15.(2),
NBC20 Div.B 2.2.3.3.(1),
NBC20 Div.B 2.2.3.7.(2),
NBC20 Div.B 2.2.6.5.(2),
NBC20 Div.B 2.2.6.9.(1),
NBC20 Div.B 2.2.8.3.(2),
NBC20 Div.B 2.2.8.3.(3),
NBC20 Div.B 2.2.8.3.(4),
NBC20 Div.B 3.1.6.3.(3),
NBC20 Div.B 3.1.6.4.(1),
NBC20 Div.B 3.1.6.4.(2),
NBC20 Div.B 3.1.6.5.(1),
NBC20 Div.B 3.1.6.9.(1),
NBC20 Div.B 3.1.9.4.(7),
NBC20 Div.B 3.1.11.5.(4),
NBC20 Div.B 3.2.3.7.(3),
NBC20 Div.B 3.2.3.7.(4),
NBC20 Div.B 3.2.7.1.(1),
NBC20 Div.B 3.2.7.1.(2),
NBC20 Div.B 3.2.7.3.(1),
NBC20 Div.B 3.2.7.3.(2),
NBC20 Div.B 3.2.7.3.(3),
NBC20 Div.B 3.2.7.3.(4),
NBC20 Div.B 3.2.7.4.(1),
NBC20 Div.B 3.2.7.4.(2),
NBC20 Div.B 3.2.7.7.(1)
Hazardous Materials and Activities: Draft
2024-10-15
-
2107Revision of Attributions and Intent Statements in Division B of NFCRevise attributions and intent statements in Division B of the NFC following an assessment of the provisions, intents, relevant objectives and functional statements.NFC20 Div.B 2.8.2.1.(3),
NFC20 Div.B 2.14.1.1.(4),
NFC20 Div.B 2.14.2.1.(1),
NFC20 Div.B 3.3.2.10.(1),
NFC20 Div.B 4.3.7.4.(1),
NFC20 Div.B 4.4.1.2.(6),
NFC20 Div.B 4.5.6.10.(1),
NFC20 Div.B 4.12.1.2.(1),
NFC20 Div.B 4.12.1.2.(3),
NFC20 Div.B 4.12.1.3.(1),
NFC20 Div.B 5.6.3.4.(1),
NFC20 Div.B 5.6.4.2.(5)
--
2105Change SCOP to "Net Sensible COP" in Table 5.2.12.1.-H as the Metric Used for Computer Room Air ConditionersThis proposed change replaces the minimum performance metric "sensible coefficient of performance (SCOP)" with the "net sensible COP (NSenCOP)" in Table 5.2.12.1.-H to harmonize with the metric used in AHRI 1360 (I-P), AHRI 1361 (SI) and ANSI/ASHRAE/IES 90.1-2022.NECB20 Div.B 5.2.12.1. Table HEnergy Efficiency: Review — Recommended for Public Review
2025-11-18
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
1873
2102Removal of a withdrawn ASTM StandardThis proposed change deletes the reference to the standard ASTM C1053, “Standard Specification for Borosilicate Glass Pipe and Fittings for Drain, Waste, and Vent (DWV) Applications,” that was withdrawn.NPC20 Div.B 2.2.8.1.HVAC and Plumbing: Review — Withdrawn
2024-12-03
-
2101Fibrocement pipe and fittingsThis proposed change prohibits the use of fibrocement pipes an fittings to covey sewage. NPC20 Div.B 2.2.5.--
2100Direct Flush ValvesThis proposed change eliminates duplicated requirements for direct flush valves by only keeping the referenced standards.NPC20 Div.B 2.2.10.8.--
2097Adding FS-OS attribution to the Part 2 of NBC 2025This proposed change aims to add FS-OS attribution to Subsection 2.2.2. of NBC 2020, ensuring consistency with other Parts of NBC 2025.NBC20 Div.B 2.2.2.,
NBC20 Div.B 3.1.16.1.
Draft
2024-10-15
-
2095Explanatory Notes on impact of thermal insulation on fire performance of envelope assemblies and cladding support This proposed change adds explanatory Notes to raise awareness of the impact of increased thermal insulation on fire resistive performance of envelope assemblies and structural support for cladding. NBC20 Div.B 9.25.2.1.,
NBC20 Div.B 9.27.5.1.
Standing Codes Coordination Committee: Review
2025-11-21
-
2090Reference to the CSA-Z32, "Electrical Safety and Essential Electrical Systems in Health Care Facilities"This proposed change clarifies the application of the referenced standard CSA-Z32, "Electrical Safety and Essential Electrical Systems in Health Care Facilities" in both NBC and NFC.NBC20 Div.B 3.2.7.5.,
NBC20 Div.B 3.2.7.6.,
NFC20 Div.B 6.5.1.1.
Use and Egress: Draft
2024-07-05
-
2089Clear Floor Space on the Non-Latch Side of Sliding DoorsThis proposed change expands the application of a clear floor space to either sides of a sliding door in a barrier-free path of travel.NBC20 Div.B 3.8.3.6.Use and Egress: Draft
2024-07-04
1700
2088Clarify the Intent of "Clear Floor Space" in Barrier-Free DesignThis proposed change clarifies the intent behind the reference to "clear floor space" when used in barrier-free design.NBC20 Div.B 3.3.2.8.,
NBC20 Div.B 3.8.
Use and Egress: Draft
2024-06-26
1701
2086Reference the individual standards within the CSA B108:23 packageReference individual standards CSA B108.1:23, "Compressed natural gas refuelling stations installation code" and CSA B108.2:23, "Liquefied natural gas refuelling stations installation code" within the CSA B108:23 Package.NFC20 Div.B 4.6.1.1.(2)Hazardous Materials and Activities: Review
2024-08-21
Hazardous Materials and Activities: Review — Recommended for Public Review
2024-10-25
-
2085Replace Existing ULC/ORD-C842-84 and CAN/ULC-S651:2016 with ANSI/CAN/UL/ULC 842:2020This proposed change replaces the reference to ULC/ORD-C842-84, "Guide for the Investigation of Valves for Flammable and Combustible Liquids," and CAN/ULC-S651:2016, "Standard for Emergency Valves for Flammable and Combustible Liquids," with a reference to ANSI/CAN/UL/ULC 842:2020, “Standard for Valves for Flammable and Combustible Liquids."NFC20 Div.B 4.5.7.1.(1),
NFC20 Div.B 4.5.7.1.(3),
NFC20 Div.B 4.6.6.3.(1)
Hazardous Materials and Activities: Review
2024-05-22
Hazardous Materials and Activities: Review — Recommended for Public Review
2024-08-21
-
2081Replace Existing ULC/ORD C107.21-92 with CAN/ULC S664:2017 This proposed change replaces the reference to ULC/ORD C107.21-92, “Under Dispenser Sumps," with a reference to CAN/ULC S664:2017, "Standard for Containment Sumps, Sump fittings, and Accessories for Flammable and Combustible Liquids"NFC20 Div.B 4.6.3.2.(1)Hazardous Materials and Activities: Review
2024-05-22
Hazardous Materials and Activities: Review — Recommended for Public Review
2024-08-21
-
2080Replace Existing CAN/ULC-S612:2016 with ANSI/CAN/UL 330:2024This proposed change replaces the reference to CAN/ULC-S612:2016, “Standard for Hose and Hose Assemblies for Flammable and Combustible Liquids," with a reference to ANSI/CAN/UL 330:2024, “Standard for Hose and Hose Assemblies for Dispensing Flammable and Combustible Liquids."NFC20 Div.B 4.6.5.1.(1)Hazardous Materials and Activities: Review
2024-05-22
Hazardous Materials and Activities: Review — Recommended for Public Review
2024-08-21
-
2079"Thermal Bridge"This proposed change introduces the defined term "thermal bridge" in the NBC and the NECB.NBC20 Div.A 1.4.1.2.,
NECB20 Div.A 1.4.1.2.
Energy Efficiency: Draft
2024-07-11
-
2078Replace Existing CAN/ULC-S620:2016 with ANSI/CAN/UL/ULC 2586:2022This proposed change replaces the reference to CAN/ULC-S620:2016, "Standard for Hose Nozzle Valves for Flammable and Combustible Liquids," with a reference to ANSI/CAN/UL/ULC 2586:2022, “Standard for Hose Nozzle Valves."NFC20 Div.B 4.5.7.1.(2),
NFC20 Div.B 4.6.5.2.(1)
Hazardous Materials and Activities: Review
2024-05-22
Hazardous Materials and Activities: Review — Recommended for Public Review
2024-08-21
-
2077Replace Existing CAN/ULC-S615-14 with ANSI/CAN/UL/ULC 1316:2018This proposed change replaces the reference to CAN/ULC-S615-14, "Standard for Fibre Reinforced Plastic Underground Tanks for Flammable and Combustible Liquids," with a reference to ANSI/CAN/UL/ULC 1316:2018, “Standard for Fibre Reinforced Underground Tanks for Flammable and Combustible Liquids."NFC20 Div.B 4.3.1.2.(1),
NFC20 Div.B 4.3.8.6.(2),
NFC20 Div.B 4.4.3.2.(4)
Hazardous Materials and Activities: Review
2024-05-22
Hazardous Materials and Activities: Review — Recommended for Public Review
2024-08-21
1523
2076Replace Existing CAN/ULC-S661-10 and CAN/ULC-S663-11 with ANSI/CAN/UL/ULC 2583:2021This proposed change replaces the reference to CAN/ULC-S661-10, “Standard for Overfill Protection Devices for Flammable and Combustible Liquid Storage Tanks," and CAN/ULC-S663-11, "Standard for Spill Containment Devices for Flammable and Combustible Liquid Aboveground Storage Tanks," with a reference to ANSI/CAN/UL/ULC 2583:2021, “Standard for Fuel Tank Accessories for Flammable and Combustible Liquids."NFC20 Div.B 4.3.1.8.(1),
NFC20 Div.B 4.3.1.8.(2),
NFC20 Div.B 4.3.6.4.(4)
Hazardous Materials and Activities: Review
2024-05-22
Hazardous Materials and Activities: Review — Recommended for Public Review
2024-08-21
-
2073Replace Existing CSA B306-M1977 to CSA B306:23This proposed change replaces the reference to CSA B306-M1977, "Portable Fuel Tanks for Marine Use," to a reference to CSA B306:23, “Portable engine fueling system for marine use."NFC20 Div.B 4.2.3.1.(1)Hazardous Materials and Activities: Review — Recommended for Public Review
2024-08-21
-
2072Replace Existing CAN/ULC-S633:2017 with ANSI/CAN/UL/ULC 2039:2023This proposed change replaces the reference to CAN/ULC-S633:2017, "Standard for Flexible Connector Piping for Fuels," with a reference to ANSI/CAN/UL/ULC 2039:2023, “Standard for Flexible Connector Piping for Flammable and Combustible Liquids."NFC20 Div.B 4.5.6.14.(2)Hazardous Materials and Activities: Review
2024-05-22
Hazardous Materials and Activities: Review — Recommended for Public Review
2024-08-21
-
2065Replace Existing ULC/ORD-C30-95 to ANSI/CAN/UL/ULC 30:2022This proposed change replaces the reference to ULC/ORD-C30-95, "Safety Containers,” to a reference to ANSI/CAN/UL/ULC 30:2022, "Standard for Metallic and Nonmetallic Safety Cans for Flammable and Combustible Liquids."NFC20 Div.B 4.1.5.8.(2),
NFC20 Div.B 4.2.3.1.(1),
NFC20 Div.B 4.2.6.4.(1),
NFC20 Div.B 5.5.5.2.(2)
Hazardous Materials and Activities: Review — Recommended for Public Review
2024-05-22
-
2064Replace Existing ULC/ORD-C1275-84 to ANSI/CAN/UL/ULC 1275:2024This proposed change replaces the reference to ULC/ORD-C1275-84, “Guide for the Investigation of Storage Cabinets for Flammable Liquid Containers," to a reference to ANSI/CAN/UL/ULC 1275:2024, “Standard for Flammable Liquid Storage Cabinets."NFC20 Div.B 4.2.10.5.(1)Hazardous Materials and Activities: Review — Recommended for Public Review
2024-05-22
Hazardous Materials and Activities: Review — Recommended for Public Review
2024-08-21
-
2061Overheating in New Dwelling Units This proposed change requires new dwelling units to be provided with mechanical cooling in locations where the outside summer design temperature exceeds 26°C.NBC20 Div.B 1.1.3.1.,
NBC20 Div.B 6.2.1.,
NBC20 Div.B 9.33.2.1.,
NBC20 Div.B 9.33.3.,
NBC20 Div.B 9.33.5.
Housing and Small Buildings: TG/WG Development
2024-02-28
Housing and Small Buildings: TG/WG Development
2024-03-14
Housing and Small Buildings: TG/WG Development
2024-04-03
Housing and Small Buildings: Review — Recommended for Public Review
2024-04-09
HVAC and Plumbing: Review — Recommended for Public Review
2024-04-15
Use and Egress: Review
2024-04-16
SC Div AC: Pre-Public Review
2024-04-22
Earthquake Design: Review
2024-04-23
Energy Efficiency: Review
2024-04-24
Structural Design: Review
2024-04-24
Environmental Separation: Review
2024-04-24
Fire Protection: Review
2024-04-24
Hazardous Materials and Activities: Review
2024-04-29
Housing and Small Buildings: Review
2024-04-29
SC Div AC: Review — Recommended for Public Review
2024-04-29
CBHCC: Pre-Public Review — Proceed
2024-04-30
Energy Efficiency: Review
2024-06-06
Housing and Small Buildings: Review of PR Comments
2024-09-04
Housing and Small Buildings: Review
2024-09-11
Housing and Small Buildings: TG/WG Development
2024-09-17
Use and Egress: Review of PR Comments
2024-09-18
Housing and Small Buildings: TG/WG Development
2024-09-26
HVAC and Plumbing: Review
2024-10-03
Housing and Small Buildings: Analysis of PR Comments — Recommend to proceed with technical revisions
2024-10-09
Housing and Small Buildings: TG/WG Development
2024-10-11
Housing and Small Buildings: Review of PR Comments — Proceed with technical revisions
2024-10-23
SC Div AC: Review of PR Comments — Proceed as proposed —
2024-10-29
Housing and Small Buildings: Review of PR Comments — Proceed with technical revisions
2024-10-29
Housing and Small Buildings: Review of PR Comments
2024-11-13
Housing and Small Buildings: Review of PR Comments — Resubmit for Public Review
2024-11-21
HVAC and Plumbing: Review of PR Comments — Proceed with technical revisions
2024-11-25
CBHCC: Review of PR Comments — Resubmit for Public Review
2024-12-05
-
2057Energy Modeling Software RequirementsThis proposed change updates the ANSI/ASHRAE Standard 140, 'Method of Test for Evaluating Building Performance Simulation Software' to its 2023 edition and adds a new Article on acceptance criteria for energy modeling software.NBC20 Div.B 9.36.5.4.(8),
NBC20 Div.B 9.36.5.,
NBC20 Div.B 9.36.2.4.(4),
NBC20 Div.B 9.36.7.3.(5),
NBC20 Div.B 9.36.5.3.(1),
NBC20 Div.B 9.36.5.15.(6),
NBC20 Div.B 9.36.7.3.(4)
Energy Efficiency: Review
2024-06-06
Energy Efficiency: Review — Withdrawn
2024-06-06
Standing Codes Coordination Committee: Review
2025-11-21
NMCC on Climate Change Mitigation: Review — Recommended for Public Review
2026-06-12
-
2054Clarification of Installation Location for Accessible ControlsThis proposed change clarifies that the prescribed height range for accessible controls should be determined in relation to the finished floor and the centre line of the controls.NBC20 Div.B 3.8.3.8.(1)Use and Egress: Draft
2024-05-10
Use and Egress: Review — Further Review
2024-06-05
NMCC on Accessibility: Review — Recommended for Public Review
2025-05-16
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
-
2053Update to CSA B651 references in NBC (if CSA B651-23 is adopted)If CSA B651-23 is adopted in the next edition of the NBC, several clause numbers need to be updated. This is an editorial update.NBC20 Div.B 3.3.1.19.,
NBC20 Div.B 3.8.3.
Use and Egress: Draft
2024-01-10
-
2050Egress Windows or Doors for Bedrooms in Part 3 Residential BuildingsThe proposed change requires egress window or door from bedrooms in Group C, Part 3 buildings that are not sprinklered.NBC20 Div.B 3.3.4.Use and Egress: Draft
2023-12-13
1591, 2095
2049Specified Wind and Snow Loads in Part 9-NBC20 Div.B 9.4.2.2.--
2047Performance Path -NECB20 Div.B 13.8.--
2046Update to Table 3.8.3.1. for CSA B651 reference to signageProvide an accurate reference in Table 3.8.3.1. to reflect the relocation of some provisions made in the CSA B651-18 standard. NBC20 Div.B 3.8.3.1.Use and Egress: Draft
2023-11-28
Use and Egress: Review — Editorial Revision/Errata (No Public Review)
2023-12-18
-
2045Tier 4 Prescriptive RequirementsThis proposed change provides the energy efficiency requirements for compliance with tier 4 of the energy performance compliance prescriptive path.NBC20 Div.B 9.36.--
2044Tier 3 Prescriptive RequirementsThis proposed change provides the energy efficiency requirements for compliance with tier 3 of the energy performance compliance prescriptive path.NBC20 Div.B 9.36.NMCC on Climate Change Mitigation: Review — Recommended for Public Review
2026-06-04
Standing Codes Coordination Committee: Review
2026-06-09
-
2043Tiered Energy Compliance: Tier 2 Prescriptive PathThis proposed change provides energy-efficiency requirements for compliance with Energy Performance Tier 2 of the energy performance compliance prescriptive path.NBC20 Div.B 9.36.11.NMCC on Climate Change Mitigation: Review — Recommended for Public Review
2025-11-18
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
-
2038Application of Automatic Sprinkler Systems and NFPA 13RThis proposed change clarifies the application of NFPA 13R, "Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies," for mixed occupancies.NBC20 Div.B 3.2.5.12.Fire Protection: TG/WG Development
2024-07-31
Fire Protection: Review
2024-09-03
Fire Protection: TG/WG Development
2024-11-18
Fire Protection: Review — Recommended for Public Review
2024-11-27
NMCC on Fire and Life Safety: Review — Recommended for Public Review
2025-09-15
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
892
2033Ventilation Systems in Existing Buildings Subjected to AlterationThis proposed change introduces requirements for ventilation systems in existing buildings subjected to alteration.NBC20 Div.B 10.9.Energy Efficiency: Review
2023-09-27
Housing and Small Buildings: Review
2023-12-06
Housing and Small Buildings: Review — Recommended for Public Review
2024-02-08
CBHCC: Pre-Public Review — Proceed
2024-04-30
Housing and Small Buildings: Review of PR Comments
2024-09-11
-
2029Accessible Menstrual Product Dispensers: Control DesignThis proposed change requires accessible control designs for menstrual product dispensers where such dispensers are provided so that they may be accessed by persons with disabilities related to dexterity.NBC20 Div.B 3.8.3.16.Use and Egress: Draft
2023-09-14
NMCC on Accessibility: Review — Recommended for Public Review
2025-05-16
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
1441
2023Fire and Sound Resistance Table UpdatesThe proposed change updates the description of the external wall assembly EW2 and EW3, and associated Table Notes.NBC20 Div.B 9.10.3.1. Table ANMCC on Fire and Life Safety: Draft
2025-07-16
-
2022Clarification of OS Safety Sub-Objective for Firefighter SafetyThis proposed change distinguishes firefighters when performing their duties from the "persons" in the definition of sub-objective OS1 Fire Safety.NPC20 Div.A 2.2.1.1.(1)--
2021Application of Accessibility Requirements to Dwelling UnitsThis proposed change revises the application of Section 3.8. exempting dwelling units from accessibility requirements.NBC20 Div.B 3.8.2.1.Use and Egress: TG/WG Development
2023-08-25
-
2020Reference House Modeling of Service Water Heating equipment not listed in Table 9.36.4.2This proposed change closes a loophole where the requirements in Table 9.36.5.16 were not aligned with Table 9.36.4.2NBC20 Div.B 9.36.5.16.Energy Efficiency: Draft
2023-08-09
-
2019Reference House Modeling of HVAC equipment not addressed in Table 9.36.3.10.This proposed change closes a loophole where the requirements in Clause 9.36.5.15.(7)(b) were not aligned with Table 9.36.3.10 in NBC 2020.NBC20 Div.B 9.36.5.15.Energy Efficiency: Draft
2023-08-04
-
2015Defined Term of DistilleryThis proposed change suggested to revise the defined term "Distillery" to avoid confusion between the property and the building on the property.NBC20 Div.A 1.4.1.2.(1)Hazardous Materials and Activities: Draft
2023-07-31
-
2014Replacing the Term "Fixture" with "Plumbing Fixture"This change identified all instances where the term "fixture(s)'' is used in the NPC 2020 and replace it with "plumbing fixture(s)" where necessary. NPC20 Div.B 2.1.3.,
NPC20 Div.B 2.1.3.2.(1),
NPC20 Div.B 2.2.2.,
NPC20 Div.B 2.2.3.1.(2),
NPC20 Div.B 2.2.3.1.(5),
NPC20 Div.B 2.2.10.8.(1),
NPC20 Div.B 2.3.3.4.(2),
NPC20 Div.B 2.3.3.8.,
NPC20 Div.B 2.3.3.11.(1),
NPC20 Div.B 2.3.3.11.(2),
NPC20 Div.B 2.3.4.1.(2),
NPC20 Div.B 2.3.4.2.(1),
NPC20 Div.B 2.3.6.1.(1),
NPC20 Div.B 2.3.6.1.(2),
NPC20 Div.B 2.3.7.3.(1),
NPC20 Div.B 2.4.2.1.(1),
NPC20 Div.B 2.4.2.1.(2),
NPC20 Div.B 2.4.2.1.(3),
NPC20 Div.B 2.4.2.3.(1),
NPC20 Div.B 2.4.2.3.(2),
NPC20 Div.B 2.4.2.3.(3),
NPC20 Div.B 2.4.3.,
NPC20 Div.B 2.4.3.4.(1),
NPC20 Div.B 2.4.4.1.(1),
NPC20 Div.B 2.4.4.2.(1),
NPC20 Div.B 2.4.4.3.,
NPC20 Div.B 2.4.4.4.(1),
NPC20 Div.B 2.4.5.1.,
NPC20 Div.B 2.4.6.4.,
NPC20 Div.B 2.4.7.4.(5),
NPC20 Div.B 2.4.9.3. Table ,
NPC20 Div.B 2.4.10.1.(1),
NPC20 Div.B 2.4.10.2.,
NPC20 Div.B 2.4.10.3.,
NPC20 Div.B 2.4.10.12.,
NPC20 Div.B 2.5.2.1.(1),
NPC20 Div.B 2.5.3.1.(1),
NPC20 Div.B 2.5.3.1.(2),
NPC20 Div.B 2.5.3.1.(3),
NPC20 Div.B 2.5.3.1.(5),
NPC20 Div.B 2.5.3.1.(6),
NPC20 Div.B 2.5.3.1.(11),
NPC20 Div.B 2.5.4.2.,
NPC20 Div.B 2.5.4.3.,
NPC20 Div.B 2.5.4.5.,
NPC20 Div.B 2.5.5.5.,
NPC20 Div.B 2.5.6.3.,
NPC20 Div.B 2.5.6.4.,
NPC20 Div.B 2.5.8.1.(2),
NPC20 Div.B 2.5.8.1. Table ,
NPC20 Div.B 2.5.9.2.(1),
NPC20 Div.B 2.6.1.1.(1),
NPC20 Div.B 2.6.1.3.(6),
NPC20 Div.B 2.6.1.6.,
NPC20 Div.B 2.6.2.2.(1),
NPC20 Div.B 2.6.2.3.(1),
NPC20 Div.B 2.6.2.10.(2),
NPC20 Div.B 2.6.2.10.(3),
NPC20 Div.B 2.6.2.10.(4),
NPC20 Div.B 2.6.3.2.,
NPC20 Div.B 2.6.3.3.(1),
NPC20 Div.B 2.6.3.4.,
NPC20 Div.B 2.7.1.1.(5),
NPC20 Div.B 2.7.1.4.(1),
NPC20 Div.B 2.7.2.4.(5),
NPC20 Div.B 2.7.2.4.(10),
NPC20 Div.B 2.2.10.6.(2),
NPC20 Div.B 2.2.10.7.,
NPC20 Div.B 2.4.5.1.(3),
NPC20 Div.B 2.4.5.1.(5),
NPC20 Div.B 2.4.8.2.(1),
NPC20 Div.B 2.4.10.,
NPC20 Div.B 2.5.3.1.,
NPC20 Div.B 2.5.4.5.(1),
NPC20 Div.B 2.5.6.3.(1),
NPC20 Div.B 2.5.6.3.(2),
NPC20 Div.B 2.6.1.3.(5),
NPC20 Div.B 2.6.3.1.(2),
NPC20 Div.B 2.6.3.4.(5)
HVAC and Plumbing: Review — Recommended for Public Review
2023-10-12
HVAC and Plumbing: Review — Withdrawn
2023-10-31
-
2012Indoor Design Temperatures for Residential Buildings-NBC20 Div.B 6.2.1.1.HVAC and Plumbing: Review
2023-09-13
HVAC and Plumbing: Review
2023-11-22
-
2007Lavatory Supply Fittings in Public WashroomsThis proposed change adds a Note to Sentence 3.7.2.3.(4) of the NBC to direct Code users to Article 2.2.10.6. of the NPC for requirements for lavatory supply fittings in public washrooms.NBC20 Div.B 3.7.2.3.HVAC and Plumbing: Review — Recommended for Public Review
2023-09-13
CBHCC: Pre-Public Review — Proceed
2024-04-30
HVAC and Plumbing: Review of PR Comments — Proceed as proposed —
2024-06-19
CBHCC: Post-Public Review — Deferred
2025-04-23
NMCC on Indoor Environment: Review — Further Review
2025-06-10
NMCC on Indoor Environment: Review — Recommended for Public Review
2025-11-04
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
-
1998Introduction of New OS Safety Sub-Objective for Firefighter SafetyThis proposed change adds a new sub-objective OS6 Firefighter Safety that clarifies which existing requirements are intended to address firefighter safety by distinguishing firefighters from the "persons" in the definition of sub-objective OS1 Fire Safety. NBC20 Div.A 2.2.1.1.(1),
NFC20 Div.A 2.2.1.1.(1)
CBHCC: Draft
2023-06-27
Environmental Separation: Review
2023-08-29
Energy Efficiency: Review
2023-09-01
Earthquake Design: Review
2023-09-07
Hazardous Materials and Activities: Review
2023-09-08
Review
2023-09-08
HVAC and Plumbing: Review
2023-09-11
Fire Protection: Review
2023-09-14
Structural Design: Review
2023-09-20
Housing and Small Buildings: Review
2023-09-26
Use and Egress: Review
2023-09-26
Fire Protection: Review
2023-10-03
Housing and Small Buildings: Review
2023-10-03
Housing and Small Buildings: Review
2023-11-01
CBHCC: Review
2024-01-24
CBHCC: Pre-Public Review — Proceed
2024-04-30
CBHCC: CBHCC Decision
2024-10-03
1857, 557
1992palce holder for 13.8-NECB20 Div.B 13.8.--
1987Outpatient ClinicsNew requirements related to operation of outpatient clinics.NFC20 Div.B 2.1.2.2.,
NFC20 Div.B 2.8.1.2.
--
1986Outpatient ClinicsNew requirements related to construction of outpatient clinics.NBC20 Div.B 3.2.7.4.,
NBC20 Div.B 3.2.7.8.
--
1985Outpatient ClinicsSignpost to Part 3 from Part 9NBC20 Div.B 9.10.1.3.--
1984Outpatient ClinicsNew requirements related to construction of outpatient clinics.NBC20 Div.B 3.3.--
1983Introduce Testing Standards for Air Barriers for Roof AssembliesThis proposed change introduces two testing standards to the NECB for air leakage through roof assemblies.NECB20 Div.B 3.2.4.3.-1997
1982Outpatient ClinicsThe proposed change introduces a new defined term for outpatient clinics.NBC20 Div.A 1.4.1.2.--
1966Withdrawing the flexibility in designation of a structure as regular from earthquake design perspectiveThis proposed change deletes the Sentence 4.1.8.6.(2) which permits that a structure which does not have any of the irregularities specified in the NBC may be considered as regular. NBC20 Div.B 4.1.8.6.--
1961Plumbing for adaptable washroom sinksThis PCF introduces new requirements for plumbing in washroom sinks to reduce the expense of lowering the height for use by wheelchair usersNBC20 Div.B 3.8.HVAC and Plumbing: Review
2023-10-12
-
1956Plumbing for adaptable kitchensThis PCF introduces new requirements for plumbing in kitchens to reduce the expense of adapting the space for use by wheelchair usersNBC20 Div.B 3.8.Use and Egress: Draft
2023-05-23
Housing and Small Buildings: Review
2023-05-31
Use and Egress: Review
2023-06-07
Use and Egress: Review
2023-07-14
Use and Egress: TG/WG Development
2023-07-24
Use and Egress: Review
2023-08-22
Use and Egress: TG/WG Development
2023-09-27
HVAC and Plumbing: Review
2023-10-12
964, 1429
1955Clarification of span limitation for wood-frame constructionThis proposed change intends to clarify that the limitation for the span of any structural member not to exceed 12.20 m in wood-frame construction refers to the clear span.NBC20 Div.B 9.23.1.1.(1)-1696
1953Clarification of requirement for panel-type underlay beneath adhesive-applied ceramic tileThis proposed change seeks to clarify the requirement for panel-type underlay to be provided under ceramic tile applied with adhesive per 9.30.2.1.(3), in addition to the subfloor having its edges supported per 9.30.6.1.(2) (i.e. ceramic tile cannot be applied with adhesive directly to the subfloor).NBC20 Div.B 9.30.6.1.(2)-1533
1949Addition of Non-asbestos Cement Board as an acceptable protection.This proposed change seeks to include 12 mm non- asbestos cement board as an acceptable material for the protection of insulation.NBC20 Div.B 9.25.2.3.(6)-1201
1948Removal of "unreinforced concrete" and "nominally reinforced concrete" in Part 9This proposed change seeks to provide clarification of Part 9 requirements for concrete by removing the term "nominally reinforced concrete" and replacing "unreinforced concrete" with "concrete".NBC20 Div.B 9.3.1.1.(1),
NBC20 Div.B 9.3.1.1.(2),
NBC20 Div.B 9.3.1.6.(1),
NBC20 Div.B 9.3.1.7.(2)
-1466
1947(CCR 2010) Adding Pointer to Relevant Requirements on Farm BuildingsThis proposed change suggested to revise Sentence 3.3.6.6.(1) of Division B of NBC to raise Code users' awareness on relevant requirements in Sentence 2.2.8.1.(4) on the classification of farm buildings used for the storage of ammonium nitrate. NBC20 Div.B 2.2.8.1.(4),
NBC20 Div.B 3.3.6.6.(1),
NFC20 Div.B 3.2.9.2.(1)
--
1943Harmonizing the Standard for Whole Building Air Leakage TestingThis proposed change harmonizes the standard for whole building air leakage testing referenced in the prescriptive and modeling requirements in the NECB by only referring to ASTM E3158, the newer, more accurate and more reproducible testing procedure. NECB20 Div.B 8.4.2.9.(2)NMCC on Climate Change Mitigation: Review — Recommended for Public Review
2025-11-18
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
1989
1941Door-Swing Area within a Universal WashroomThis proposed change clarifies that the 1700 mm diameter turning space within a universal washroom does not overlap with the space occupied by an inward swinging door.NBC20 Div.B 3.8.3.13.(1)Use and Egress: Draft
2024-06-10
1782
1937Exhaust Ducts Serving Laundry-drying Equipment This change will provide clarification of the requirements for exhaust ducts referenced in Sentence 9.32.1.3.(2) by directly stating in the body of the code the practicality that Note A-9.32.1.3 provides and will ensure consistency between Sentences 6.3.2.10(7) and 9.32.1.3.(2).NBC20 Div.B 9.32.1.3.(2),
NBC20 Div.B 6.3.2.10.(7)
-1355
1935OP Objective and Intent Statement for Farm Buildings in NBCIntroduces OP objectives and intent statements for farm building requirements in the NBC. NBC20 Div.B 2Draft
2023-08-23
Fire Protection: Review
2023-09-14
Hazardous Materials and Activities: Review — Editorial Revision/Errata (No Public Review)
2023-09-22
Hazardous Materials and Activities: Review
2023-10-28
Hazardous Materials and Activities: Review
2024-03-22
Fire Protection: Review
2024-03-27
CBHCC: Review — Withdrawn
2024-04-30
Fire Protection: Review
2024-06-03
-
1908Modernizing the language in washroom provisionsThe proposed change modernizes the language in washroom provisions in the NBC to include gender-based terms instead of sex-based termsNBC20 Div.B 3.7.2.2.Use and Egress: Draft
2024-04-17
Use and Egress: Review — Further Review
2024-06-04
-
1907Width of doorways around non-exit stairsExpanding the application of Sentence 3.4.3.3.(1) to doorways around non-exit stairsNBC20 Div.B 3.3.1.14.(1)-1251
1906Application of Dampproofing MaterialThis code change is to clarify the proper application of dampproofing material to foundation walls as found in Sentence 9.13.2.1.(1).NBC20 Div.B 9.13.2.1.(1)-1547
1902Clarifications for Artcile 4.1.8.3.-NBC20 Div.B 4.1.8.3.--
1895Datum for the Determination of N̅60 and s̅u in Article 4.1.8.1.The proposed change revises the datum used for the determination of N̅60 and s̅u in Article 4.1.8.1. to make it consistent with that used in the rest of Subsection 4.1.8.NBC20 Div.B 4.1.8.1.Earthquake Design: Review — Recommended for Public Review
2023-08-30
CBHCC: Pre-Public Review — Proceed
2024-01-25
Earthquake Design: Review of PR Comments — Withdrawn
2024-06-03
1640, 1457
1893In-factory Airtightness Testing of Factory-constructed BuildingsThis proposed change introduces the in-factory airtightness testing requirement for single-section, single-story, factory-constructed buildings.NBC20 Div.B 9.36.6.3.-1871
1891(split from PCF 1819) Harmonize Airtightness Requirements in NBC Section 9.36.This proposed change (1) aligns the airtightness requirements in the Tiered Performance Path with the Performance Path, and (2) allow the use of 3.0 or 2.5 ACH50 for proposed house modelling without conducting an airtightness test for attached and detached houses, respectively .---
1887Passive Stack Radon Mitigation with Active Radon Stack OptionThe addition of passive vertical stack radon mitigation systems, as well as an active side wall mitigation option, to dwelling units and building containing residential occupancies in contact with the ground.NBC20 Div.B 9.13.4.Housing and Small Buildings: Review — Further Review
2022-06-08
895, 951, 1330, 1519
1885Location of Water-bottle Filling Stations and Drinking Fountains in a Building Required to be Barrier-freeThis proposed change clarifies where a water-bottle filling station and a drinking fountain complying with Subsection 3.8.3. should be provided in a barrier-free building.NBC20 Div.B 3.8.2.8.(10),
NBC20 Div.B 3.8.2.8.(11)
Use and Egress: Draft
2024-05-29
1822
1877(on-hold) Adjustment Factor for Unguarded Blower Door Airtightness Testing ResultsThis proposed change introduces an adjustment factor for the airtightness results of unguarded blower door testing of attached units.NBC20 Div.B 9.36.6.3.,
NBC20 Div.B 9.36.6.4.,
NBC20 Div.B 9.36.7.3.,
NBC20 Div.B 9.36.8.8.
Housing and Small Buildings: Review
2023-06-08
-
1871Heat Pump Water Heater ModellingThis updates the modelling rules for the reference house when the proposed house uses a heat pump water heaterNBC20 Div.B 9.36.7.3.--
1856Rooftop enclosures as a storyThis proposed change clarifies whether a rooftop enclosure should be counted as a storey of building.NBC20 Div.B 3.2.1.1.,
NBC20 Div.B 3.2.5.8.,
NBC20 Div.B 3.2.6.1.,
NBC20 Div.B 3.5.4.1.
Fire Protection: Draft
2023-02-20
Fire Protection: Review — Withdrawn
2023-03-16
1567, 1568, 1569
1855Maximum Travel of Enclosed Vertical Platform Lifts for PassengersThis proposed change limits the travel of enclosed vertical platform lifts.NBC20 Div.B 3.8.3.7.Use and Egress: Draft
2023-02-17
NMCC on Accessibility: Review — Withdrawn
2025-05-16
1593
1854Rooftop Enclosures as a StoreyThis proposed change clarifies whether a rooftop enclosure provided for elevator machinery, a stairway or a service room is intended to be considered as a storey in certain fire safety applications.NBC20 Div.B 3.2.5.8.,
NBC20 Div.B 3.2.6.1.
Fire Protection: Draft
2023-02-14
Fire Protection: Review — Recommended for Public Review
2023-03-16
Use and Egress: Review
2023-06-07
TG/WG Development
2023-07-11
Fire Protection: Review
2024-03-27
CBHCC: Review — Deferred
2024-04-30
Fire Protection: Review
2024-06-03
1568, 1569
1849Hot Works Site Preparation and Safety ChecksThis proposed change lists the required activities to reduce the potential of accidental ignition of combustible materials from hot works.NFC20 Div.B 5.2.1.,
NFC20 Div.B 5.2.3.
NMCC on Fire and Life Safety: Draft
2025-12-08
-
1848Hot Work Permit SystemThis proposed change sets the parameters to initiate a hot work permit system.NFC20 Div.C 2.2.NMCC on Fire and Life Safety: Draft
2025-12-08
-
1837Prescriptive Trade-off Path - Heat Pump Water HeatersThis proposed change updates the energy conservation points assigned to heat pump water heatersNBC20 Div.B 9.36.8.10.--
1822Thermal Bridging Requirements Section 9.36.Update the thermal bridging requirements to reflect new modelling and standardsNBC20 Div.B 9.36.2.Housing and Small Buildings: Review
2023-06-08
Energy Efficiency: Draft
2023-08-23
NMCC on Climate Change Mitigation: Review — Withdrawn
2025-12-17
-
1819Removing ACH50 and Harmonizing Airtightness Requirements in Section 9.36.This proposed change replaces ACH50 with NLR50 as the regulating airtightness metric in Section 9.36. and revises the airtightness requirements in the compliance paths and for proposed house modeling.NBC20 Div.B 9.36.5.10.,
NBC20 Div.B 9.36.5.14.,
NBC20 Div.B 9.36.6.4.,
NBC20 Div.B 9.36.7.3.
Energy Efficiency: Review — Recommended for Public Review
2023-08-21
Housing and Small Buildings: Review
2023-10-10
CBHCC: Pre-Public Review — Proceed
2024-01-25
Energy Efficiency: Review of PR Comments — Defer
2024-06-06
NMCC on Climate Change Mitigation: Review — Withdrawn
2025-12-17
-
1817Direction of Door Swing with Low Occupant LoadThis proposed change permits an exit door serving an area with a low occupant load to swing inward.NBC20 Div.B 3.4.6.12.Use and Egress: Draft
2024-05-27
999
1816Small Quantity Exemptions for Dangerous GoodsThis proposed change simplifies the requirements for the small quantity exemptions of dangerous goods.NFC20 Div.B 3.2.7.1.NMCC on Fire and Life Safety: TG/WG Development
2025-08-13
-
1814Removing the NLA Airtightness MetricThis proposed change removes the normalized leakage area (NLA) metric for airtightness level determination.NBC20 Div.B 9.36.6.2.,
NBC20 Div.B 9.36.6.3.,
NBC20 Div.B 9.36.6.4.
Draft
2022-11-04
Energy Efficiency: Review
2023-03-01
Housing and Small Buildings: Review
2023-06-08
CBHCC: Review — Recommended for Public Review
2023-08-17
Energy Efficiency: Review of PR Comments — Withdrawn
2024-06-06
-
1807Introduction of Requirements for Screens and Curtains Used in Farm BuildingsThis proposed change introduces flame-testing requirements for screens and curtains used in farm buildings, and includes options to divide screens and curtains into smaller, non-contiguous areas.NFC20 Div.B 2.3.2.Hazardous Materials and Activities: TG/WG Development
2022-10-12
Hazardous Materials and Activities: Review
2023-08-15
Hazardous Materials and Activities: TG/WG Development
2023-08-23
Hazardous Materials and Activities: Review
2023-09-06
Fire Protection: Review — Recommended for Public Review
2023-09-14
CBHCC: Pre-Public Review — Proceed
2024-01-25
Hazardous Materials and Activities: Review of PR Comments
2024-05-22
Fire Protection: Review of PR Comments — Withdrawn
2024-06-03
1644
1806Fabrics, Films and Membranes Used in Farm Building Envelope ConstructionThis proposed change introduces flame-spread rating requirements for fabrics, films and membranes when used in building envelope construction and provides an exemption for Group G, Division 4 major occupancy.NBC20 Div.B 2.2.1.14.Hazardous Materials and Activities: TG/WG Development
2022-09-12
Hazardous Materials and Activities: Review
2023-08-15
Fire Protection: Review — Deferred
2023-11-20
Fire Protection: Review
2024-03-01
Fire Protection: Review — Deferred
2024-06-03
1611, 1661
1804Updates to Referenced Documents-NBC20 Div.B 1.3.1.2.,
NFC20 Div.B 1.3.1.2.,
NPC20 Div.B 1.3.1.2.,
NECB20 Div.B 1.3.1.2.
Earthquake Design: Review
2022-09-09
Housing and Small Buildings: Review
2022-09-13
Use and Egress: Review
2022-09-28
HVAC and Plumbing: Review
2022-09-28
Hazardous Materials and Activities: Review
2022-09-29
Structural Design: Review
2022-09-29
Fire Protection: Review
2022-10-04
Energy Efficiency: Review
2022-10-13
Environmental Separation: Review
2022-10-13
EC: Review — Recommended for Public Review
2022-10-13
HVAC and Plumbing: Review of PR Comments
2023-02-24
Fire Protection: Review of PR Comments
2023-03-02
Use and Egress: Review of PR Comments
2023-03-15
Energy Efficiency: Review of PR Comments
2023-04-04
Structural Design: Review of PR Comments
2023-04-04
Environmental Separation: Review of PR Comments
2023-04-05
Hazardous Materials and Activities: Review of PR Comments
2023-05-02
Housing and Small Buildings: Review of PR Comments
2023-05-31
Earthquake Design: Review of PR Comments
2023-06-08
SC Div AC: Review of PR Comments — Proceed with editorial revisions
2023-08-09
CBHCC: CCBFC Decision — Approved for publication
2024-04-30
-
1787Combustible Projections to Property LineThis proposed change revises Sentence 3.2.3.6.(5) to reference "property line". NBC20 Div.B 3.2.3.6.(5)Fire Protection: Review — Further Review
2022-05-05
Fire Protection: Review — Editorial Revision/Errata (No Public Review)
2022-09-22
852
1783Identification of Sanitary Drainage SystemThis CCR aims to add color requirements for the identification of the sanitary drainage system to Article 2.2.1.3. IdentificationNPC20 Div.B 2.2.1.3.-1630
1781Fire Test Method for Firestops at Perimeter JointsThis proposed change replaces the referenced standard for fire test method, ASTM E2307, "Standard Test Method for Determining Fire Resistance of Perimeter Fire Barriers Using Intermediate-Scale, Multi-story Test Apparatus," with CAN/ULC-S115:2023, "Standard Method of Fire Tests of Firestop Systems."NBC20 Div.B 3.1.8.3.(2),
NBC20 Div.B 3.1.8.3.(4),
NBC20 Div.B 9.10.9.2.(4)
Fire Protection: Draft
2024-05-06
Fire Protection: Review — Recommended for Public Review
2024-06-03
Housing and Small Buildings: Review
2024-06-19
Housing and Small Buildings: Review — Recommended for Public Review
2024-08-14
Fire Protection: Review
2024-09-03
NMCC on Fire and Life Safety: Review — Recommended for Public Review
2025-09-15
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
-
1780Benches in Universal Dressing and Shower RoomsThis proposed change requires minimum loading and maintenance quality requirements for benches in universal dressing and shower rooms.NBC20 Div.B 3.8.3.17.Use and Egress: Draft
2022-08-11
Use and Egress: Review — Further Review
2024-06-04
1690
1779Location of Toilet Paper Dispenser within an Accessible Water-Closet StallThis proposed change sets the location of a toilet paper dispenser within an accessible water-closet stall.NBC20 Div.B 3.8.3.12.(1)Use and Egress: Draft
2024-06-21
NMCC on Accessibility: TG/WG Development
2026-04-30
1780
1778Replace the Term "Hearing Impairment" with "People with Low or No Hearing"This proposed change replaces the term "hearing impaired" with "people with low or no hearing" in Part 3. NBC20 Div.B 3.2.4.19.,
NBC20 Div.B 3.8.
Use and Egress: Draft
2022-08-10
Use and Egress: Review — Further Review
2024-06-04
Draft
2025-02-27
NMCC on Accessibility: Review — Recommended for Public Review
2025-05-16
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
1528
1770Audible and visible signal devicesThis PCF updates requirements for silencing and function of visible alarmsNBC20 Div.B 3.2.4.Use and Egress: TG/WG Development
2021-11-19
1408
1769Lighting within an Occupied WashroomThis proposed change introduces a minimal reasonable timeframe of illumination in an occupied washroom.NBC20 Div.B 9.34.2.7.Use and Egress: Draft
2021-12-21
Use and Egress: Review
2022-05-25
Housing and Small Buildings: Review
2022-06-08
Energy Efficiency: Review
2022-07-20
Use and Egress: Review
2022-11-09
Use and Egress: Review
2023-09-26
Housing and Small Buildings: Review — Recommended for Public Review
2024-02-08
Energy Efficiency: Review
2024-04-04
Housing and Small Buildings: Review — Deferred
2024-04-12
Use and Egress: Review
2024-06-05
1545
1765Projection of Protruding Building ElementsThis proposed change extends the Part 9 requirements on the projection of protruding building elements to most paths of travel. NBC20 Div.B 9.5.,
NBC20 Div.B 9.9.5.3.,
NBC20 Div.B 3.3.1.8.(2),
NBC20 Div.B 3.3.1.8.(3)
Use and Egress: Draft
2022-01-04
Use and Egress: TG/WG Development
2022-08-11
Use and Egress: Review
2022-09-28
Housing and Small Buildings: Review
2022-10-06
TG/WG Development
2022-12-12
Housing and Small Buildings: Review — Further Review
2023-01-18
TG/WG Development
2023-02-06
Use and Egress: Review
2023-05-02
Housing and Small Buildings: Review — Recommended for Public Review
2023-05-31
CBHCC: Review — Recommended for Public Review
2023-08-17
Housing and Small Buildings: Review of PR Comments
2024-01-30
Use and Egress: Review of PR Comments
2024-03-08
Housing and Small Buildings: Review of PR Comments — Defer
2024-06-19
685
1764Tactile Attention Indicator SurfacesThis proposed change introduces requirements on the provision of tactile attention indicator surfaces at certain changes in elevation.NBC20 Div.B 3.3.1.19.,
NBC20 Div.B 9.8.6.
Use and Egress: Draft
2022-03-01
Use and Egress: TG/WG Development
2022-08-11
Use and Egress: Review
2022-09-28
Use and Egress: TG/WG Development
2022-12-12
-
1751Requirements for Non-fixed Seating in Assembly OccupanciesThis proposed change updates the NFC requirements for non-fixed seating in assembly occupancies and introduces an explanatory Note regarding standing-only spaces in assembly occupancies.NFC20 Div.B 2.7.1.5.Use and Egress: Draft
2022-01-03
Use and Egress: TG/WG Development
2022-03-24
Use and Egress: TG/WG Development
2022-04-14
Use and Egress: Review — Recommended for Public Review
2022-05-25
Use and Egress: Analysis of PR Comments — Recommend to withdraw
2023-01-24
Use and Egress: Review of PR Comments — Withdrawn
2023-03-15
400
1730Tests and Inspection of Drainage or Venting SystemsVisual inspection of the pipe systemNPC20 Div.B 2.3.6.1.HVAC and Plumbing: TG/WG Development
2022-05-26
HVAC and Plumbing: Review — Withdrawn
2022-07-29
1635
1715Washroom TerminologyCoordinate the identification and replacement of multiple terms that have been used interchangeably in the NBC with the term "washroom"NBC20 Div.B 9.32.3.7.(4),
NBC20 Div.B 9.32.3.7.(7),
NBC20 Div.B 9.32.3.11.(1),
NBC20 Div.B 9.5.4.1.(1),
NBC20 Div.B 9.9.5.9.(1),
NBC20 Div.B 9.10.12.4.(5),
NBC20 Div.B 9.10.14.4.(7),
NBC20 Div.B 9.10.17.11.(1),
NBC20 Div.B 9.23.15.2.(4),
NBC20 Div.B 9.32.3.3.(10),
NBC20 Div.B 9.33.6.10.(2),
NBC20 Div.B 9.33.6.11.(2),
NBC20 Div.B 9.34.2.2.(1)
Housing and Small Buildings: Review
2022-12-08
HVAC and Plumbing: Review
2023-09-13
Housing and Small Buildings: Review — Withdrawn
2024-02-08
Housing and Small Buildings: Review — Withdrawn
2024-06-20
-
1710Washrooms/bathroom and other interchangeable termsCoordinate the identification and replacement of multiple terms that have been used interchangeably in the NBC with the term "washroom"NBC20 Div.B 3.1.13.3.,
NBC20 Div.B 3.2.2.21.(1),
NBC20 Div.B 3.3.3.5.,
NBC20 Div.B 3.4.4.4.(8),
NBC20 Div.B 3.8.3.6.(3),
NBC20 Div.B 3.2.6.2.(5),
NBC20 Div.B 3.2.4.20.(9),
NBC20 Div.B 3.2.2.35.(4)
--
1708Maximum length of barrier-free rampsProvide guidance for overall length of barrier-free ramps recognizing that travel in either direction on a barrier-free ramp requires increased strength and stamina by all users.NBC20 Div.B 3.8.3.5.Use and Egress: TG/WG Development
2021-12-10
NMCC on Accessibility: TG/WG Development
2025-09-16
NMCC on Accessibility: TG/WG Development
2025-11-20
1544
1705L-shaped grab bar for water-closet stalls for persons with limited mobilityThis PCF requires an L-shaped grab bar instead of a horizontal grab bar at water-closets for stalls for people with limited mobility. NBC20 Div.B 3.8.3.15.,
NBC20 Div.B 3.8.3.12.
Use and Egress: TG/WG Development
2021-12-10
NMCC on Accessibility: TG/WG Development
2025-07-04
NMCC on Accessibility: TG/WG Development
2025-09-16
-
1701Spatial separation table valuesThis proposed change adds the equation upon which the values in spatial separation tables in Part 9 were based to the Notes to Part 9.NBC20 Div.B 9.10.14.4.,
NBC20 Div.B 9.10.15.4.
TG/WG Development
2021-04-15
Fire Protection: Review
2021-10-27
1183
1700Activation of smoke dampers by smoke detectorThis proposed change clarifies that the activation of smoke damper and combination smoke/fire damper does not necessarily require a fire alarm system where it is not required. NBC20 Div.B 3.2.4.10.(1)Use and Egress: Draft
2021-10-06
Fire Protection: Review — Withdrawn
2021-10-26
-
1697Cross reference to firestopping provisions for permitted service penetrationsThis proposed change adds a cross reference to firestopping provisions for permitted service penetrations where Article 9.10.18.6. allows each portion of a building on either side of a 1 hour fire rated separation to be treated as a separate building.NBC20 Div.B 9.10.18.6.(1)Fire Protection: Draft
2021-10-06
Fire Protection: Review
2021-10-26
1126
1696Drains Serving Elevator Pits-NPC20 Div.B 2.4.3.6.HVAC and Plumbing: Draft
2021-09-27
1420
1695Wet Vents-NPC20 Div.B 2.5.6.2.-1102
1694Air gaps permitted in a noxious environmentThis proposed change allows air gaps to be located in a noxious environment when a zone protection is provided outside that noxious environment.NPC20 Div.B 2.6.2.9.HVAC and Plumbing: Draft
2021-09-27
HVAC and Plumbing: TG/WG Development
2022-02-18
HVAC and Plumbing: Review — Withdrawn
2022-10-25
1220
1685Reference CAN/ULC-S134 for protection of foamed plastic This proposed change modifies the test requirements for protection of foamed plastic in exterior walls.NBC20 Div.B 3.2.3.8.TG/WG Development
2021-04-12
Fire Protection: Review
2021-05-06
-
1684Revision of Intent Statements and Attributions for NBC Sentences 3.2.3.7.(3) and (4)This proposed change deletes the attributions and revises the intent statements for Sentences 3.2.3.7.(3) and (4) of Division B of the NBC. NBC20 Div.B 3.2.3.7.(3),
NBC20 Div.B 3.2.3.7.(4)
Fire Protection: TG/WG Development
2021-05-07
Fire Protection: Review — Recommended for Public Review
2021-05-13
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
-
1681Distillery as a medium-hazard industrial occupancyThis proposed change adds distilleries as an example of medium-hazard industrial occupancy in the NBC and NFC. NBC20 Div.B 3.1.2.1.(1),
NFC20 Div.B 4.10.2.1.
TG/WG Development
2021-04-17
Fire Protection: Review — Further Review
2021-05-13
Hazardous Materials and Activities: Review — Further Review
2021-09-29
1208
1666Barrier-free path of travel connecting barrier-free facilitiesThis proposed change requires that where clear floor spaces are required for barrier-free facilities, that they be connected to the barrier-free path of travel. NBC20 Div.B 3.8.2.3.,
NBC20 Div.B 3.8.3.2.
NMCC on Accessibility: TG/WG Development
2025-06-23
NMCC on Accessibility: TG/WG Development
2025-09-16
NMCC on Accessibility: TG/WG Development
2025-11-20
NMCC on Accessibility: Review — Recommended for Public Review
2026-01-09
Standing Codes Coordination Committee: Review
2026-04-29
1781, 1783
1644Replace the Term "Visually Impaired Persons" with "People with Low or No Vision"This proposed change replaces the terms "visually impaired persons" and "people with vision loss" with "people with low or no vision" in Parts 3 and 9.NBC20 Div.B 3.3.1.8.(2),
NBC20 Div.B 3.8.,
NBC20 Div.B 9.8.7.3.(1),
NBC20 Div.B 9.8.7.3.(2),
NBC20 Div.B 9.9.5.3.(1)
Use and Egress: Draft
2020-02-04
Use and Egress: Review
2024-06-04
Draft
2025-02-27
NMCC on Accessibility: Review — Recommended for Public Review
2025-05-16
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
1528
1638Protection of electrical conductors within a storeyClarification of wording on the exemption of electrical conductor protection for fire alarm system branch circuits connecting individual devices and transponders in a single storeyNBC20 Div.B 3.2.7.10.(7)Use and Egress: Draft
2019-10-01
Use and Egress: Review
2022-05-25
Housing and Small Buildings: Review
2022-06-08
Use and Egress: Review — Editorial Revision/Errata (No Public Review)
2022-06-20
1407
1589Vision glass in doors in primary horizontal routesThis change proposes to require that doors in primary horizontal routes be provided with a vision panel.NBC20 Div.B 3.3.1.20.Use and Egress: TG/WG Development
2019-05-07
Use and Egress: TG/WG Development
2019-06-12
Use and Egress: Review — Further Review
2019-06-18
Use and Egress: TG/WG Development
2022-05-11
2049
1585Handrail Colour Contrast This proposed change adds a requirement of colour contrast for handrails compared to the adjacent background and wall surfaces. NBC20 Div.B 3.4.6.5.Use and Egress: Draft
2019-04-29
Use and Egress: TG/WG Development
2019-05-07
Use and Egress: TG/WG Development
2022-11-07
-
1583Accessible Parking This proposed change introduces requirements for accessible parking areas in the NBC. NBC20 Div.B 3.8.2.5.,
NBC20 Div.B 3.8.3.
Use and Egress: TG/WG Development
2019-04-29
Use and Egress: Review — Further Review
2019-05-29
Use and Egress: TG/WG Development
2019-06-12
Use and Egress: Review — Further Review
2019-06-18
Use and Egress: TG/WG Development
2022-03-11
-
1582Grab Bars in Bathtubs and ShowersThis proposed change introduces a requirement for the installation of grab bars in all bathtubs and showers.NBC20 Div.B 9.31.1.,
NBC20 Div.B 9.31.2.
Housing and Small Buildings: Review
2019-05-22
Housing and Small Buildings: Review — Recommended for Public Review
2019-06-25
TG/WG Development
2020-09-03
Housing and Small Buildings: Review of PR Comments
2021-02-25
Use and Egress: Review of PR Comments
2021-03-14
Use and Egress: Review of PR Comments
2021-03-29
Use and Egress: Review of PR Comments
2021-04-23
Use and Egress: Review of PR Comments
2021-05-05
Housing and Small Buildings: Review of PR Comments — Defer
2021-05-11
235, 994
1581Grab Bars for Bathtubs and ShowersThis proposed change introduces requirements on the installation of grab bars for bathtubs and showers.NBC20 Div.B 3.7.2.Housing and Small Buildings: Review
2019-05-22
Use and Egress: Review — Recommended for Public Review
2019-05-29
Housing and Small Buildings: Review
2019-06-25
Use and Egress: Review
2019-06-25
Use and Egress: Review
2019-07-16
Housing and Small Buildings: Review of PR Comments
2020-05-29
Housing and Small Buildings: Review of PR Comments
2020-06-12
TG/WG Development
2020-09-03
Housing and Small Buildings: Analysis of PR Comments
2021-02-25
Housing and Small Buildings: Analysis of PR Comments
2021-03-10
Use and Egress: Review of PR Comments
2021-03-15
Use and Egress: Review of PR Comments
2021-03-29
Use and Egress: Review of PR Comments
2021-04-23
Use and Egress: Review of PR Comments — Defer
2021-05-05
235, 994
1578Step dimensions in dwelling unitsThis proposed change harmonizes step dimensions in dwelling units (rise and run) with step dimensions in public buildings NBC20 Div.B 9.8.4.-1232
1575Change Defined Term "Barrier-free" to "Accessible"The proposed changes replace the term "barrier-free" by "accessible" in the NBC.NBC20 Div.A 1.4.1.2.,
NBC20 Div.A 2.2.1.1.(1),
NBC20 Div.A 2.1.1.2.(5)
Use and Egress: TG/WG Development
2019-04-24
Use and Egress: Review
2019-05-30
EC: Review — Editorial Revision/Errata (No Public Review)
2019-07-11
EC: Review — Further Review
2019-12-13
EC: TG/WG Development
2021-07-21
Draft
2025-02-27
2235, 2244
1572Tactile attention indicator surfaces (TAIS) for exit StairsThe change proposed location where TAIS shall be installed in exit stairs.NBC20 Div.B 3.3.1.19.Use and Egress: TG/WG Development
2019-05-07
Use and Egress: TG/WG Development
2019-06-12
Use and Egress: Review — Further Review
2019-06-18
Use and Egress: TG/WG Development
2022-11-07
-
1507Minimum Cleanout Fitting Dimension This proposed change sets the minimum dimension for cleanout fittings to be at least 4 in. in size for building drains that are at least 4 in. in size.NPC20 Div.B 2.4.7.HVAC and Plumbing: Draft
2019-02-28
1227
1470Backwater valve and sump pit drainageAddition of backwater valves to Article 9.14.5.2. and clarification of discharge location of sump pits.NBC20 Div.B 9.14.5.,
NECB20 Div.B 8.4.5.1.
Housing and Small Buildings: Review — Deferred
2019-05-23
HVAC and Plumbing: Review
2023-03-13
-
1464Coatings of connectors and fasteners in contact with treated woodThe proposed change would revise Subsection 9.23.6. to increase the galvanized coating criteria for fasteners and connectors in contact with pressure-treated wood.NBC20 Div.B 9.23.2.-508
1440Limiting Distance and Fire Department ResponseThis proposed change clarifies that the locations exempted from having to be sprinklered according to the standards referenced in Article 3.2.5.12. are not actually exempted in the context of the application of Article 9.10.15.3. when they are located adjacent to the exposing building face. NBC20 Div.B 9.10.15.3.Housing and Small Buildings: Review — Recommended for Public Review
2019-05-24
Housing and Small Buildings: Review of PR Comments — Defer
2020-12-16
-
1432Required Handrails for Stairs Serving a Single Dwelling Unit or a House with a Secondary SuiteThis proposed change harmonizes the number of handrails required for interior and exterior stairs and ramps serving a single dwelling unit or a house with a secondary suite.NBC20 Div.B 9.8.7.1.Housing and Small Buildings: Review — Recommended for Public Review
2019-05-23
Use and Egress: Review of PR Comments
2020-06-25
Housing and Small Buildings: Review of PR Comments — Defer
2020-08-12
-
1429Graspability of HandrailsChange to Part 9 handrail graspability design to align with Part 3 definition of graspable.NBC20 Div.B 9.8.7.5.-966, 1328
1393Defined Term Storm WaterThe proposed change would harmonize between the English and the French definition of the term storm water.NPC20 Div.A 1.4.1.2.-1063
1389Location of Drain PipesThis proposed change requires that a drain pipe that is directly connected to multiple fixture outlet pipes or a fixture drain be located within a single room or suite. NPC20 Div.B 2.4.2.3.HVAC and Plumbing: Draft
2019-02-28
HVAC and Plumbing: Review — Recommended for Public Review
2019-04-17
HVAC and Plumbing: Review of PR Comments — Defer
2020-05-12
TG/WG Development
2022-02-15
TG/WG Development
2022-03-21
HVAC and Plumbing: Review — Withdrawn
2022-09-28
1187
1381Drainage to Sumps by GravityThe proposed change would prohibit the use of a sump or tank on piping that can drained by gravity.NPC20 Div.B 2.4.6.3.HVAC and Plumbing: TG/WG Development
2018-09-12
1023
1367Capability of SupportThe proposed change would add clarification to the Sentence 2.3.4.1.(2)-HVAC and Plumbing: Draft
2018-07-16
1099
1353Location of Low Permeance MaterialsThis proposed change clarifies the application of Table 9.25.5.2.NBC20 Div.B 9.25.5.2.Housing and Small Buildings: Review — Recommended for Public Review
2019-05-23
Housing and Small Buildings: Review of PR Comments
2020-05-08
Housing and Small Buildings: Review of PR Comments — Defer
2020-07-20
-
1299Long-life Sealed Battery Smoke AlarmsThis proposal permits long-life sealed battery smoke alarms in location where the codes allow the used of battery-operated smoke alarms.NFC20 Div.B 2.1.3.3.,
NBC20 Div.B 9.10.19.4.
Draft
2022-05-02
Use and Egress: Review
2024-04-05
1216
1237Handrails: A-9.8.7.5. Ergonomic Design. Notion of "graspability of the handrails"This proposed change clarifies the notion of "graspability of the handrails"NBC20 Div.B 9.8.7.5.--
1233Handrails: Dimensional limits for handrail cross-sections for Part 9 BuildingsThis proposed change would revise Article 9.8.7.5. Ergonomic Design to introduce the dimensional limits for handrail cross-sections for Part 9 buildingsNBC20 Div.B 9.8.7.5.--
1141Application of 9.10.15. to garages and carportsThis Proposed change clarifies how to apply spatial separations requirements to attached garages and attached carports to dwelling unitsNBC20 Div.B 9.10.15.1.Housing and Small Buildings: Review — Deferred
2018-07-09
Housing and Small Buildings: Review — Deferred
2019-05-24
-
1077Inspection, Testing and MaintenanceThis proposed change clarifies that municipal hydrants are required to comply with the requirements for inspection, testing, and maintenance in accordance with Sentence 6.4.1.1.(1) of Division B of the NFC. NFC20 Div.B 6.4.1.1.Hazardous Materials and Activities: Review — Recommended for Public Review
2017-05-16
Pre-Public Review — Proceed
2017-10-26
Hazardous Materials and Activities: Review of PR Comments — Defer
2018-05-28
1043
855Spatial Separation Requirements and Fire Department Response Time- Option 3This proposed change eliminates the 10 Min response time, states that the requirements in Subsection 9.10.15. are the default based on the assumption that the AHJ have evaluated the firefighting capabilities and explains in an Appendix Note the fallback position.NBC20 Div.B 9.10.15.--
854Spatial Separation requirements and Fire Department Response Time - Option 2This proposed change eliminates the 10 Min response time, allows the AHJ to establish its own limiting distance or apply the traditional limiting distance restrictions and explains in an Appendix Note the fire department assumptions based on which the code requirements were developed.NBC20 Div.B 9.10.15.--
853Spatial Separation Requirements and Fire Department Response Time- Option 1This proposed change eliminates the 10 Min response time without replacement and explains in an Appendix Note (Linked to the Subsection title) the fire department assumptions based on which the code requirements were developed.NBC20 Div.B 9.10.15.--
851Travel limit to exitThis propose changes provides relaxations to travel limit to exit in a sprinklered buildingsNBC20 Div.B 9.9.9.1.--
805Replace CSA A82.31 with ASTM C840 on Gypsum Board InstallationThis proposed change replaces the reference to an outdated CSA standard with an up-to-date acceptable ASTM standard on gypsum board installation and makes Part 5, Part 9 and Appendix D consistent.NBC20 Div.B 9.29.5.1.(2),
NBC20 Div.B 9.10.9.2.(5),
NBC20 Div.B 9.10.12.4.(3),
NBC20 Div.B 9.10.14.5.(8),
NBC20 Div.B 9.10.14.5.(12),
NBC20 Div.B 9.10.15.5.(7),
NBC20 Div.B 9.10.15.5.(11)
Housing and Small Buildings: TG/WG Development
2013-10-21
Housing and Small Buildings: Review — Deferred
2013-11-20
Fire Protection: Review
2014-04-29
-
741Information Required on Structural DrawingsThis proposed change deletes the reference to cladding in Sentence (1) and adds a new Sentence dealing with structural drawings of secondary structural elements. NBC20 Div.C 2.2.4.3.Structural Design: Review
2013-04-05
Structural Design: Review
2019-03-18
Environmental Separation: Review
2019-04-12
EC: Review — Further Review
2019-07-11
Structural Design: Review
2019-07-24
EC: Review — Recommended for Public Review
2019-08-06
Structural Design: Analysis of PR Comments
2020-04-20
Environmental Separation: Review of PR Comments
2020-04-30
Use and Egress: Review of PR Comments
2020-05-11
Energy Efficiency: Review of PR Comments
2020-05-11
Hazardous Materials and Activities: Review of PR Comments
2020-05-12
Fire Protection: Review of PR Comments
2020-05-14
HVAC and Plumbing: Review of PR Comments
2020-06-11
Earthquake Design: Review of PR Comments
2020-06-15
Housing and Small Buildings: Review of PR Comments
2020-06-26
Structural Design: Review of PR Comments
2020-07-20
EC: Review of PR Comments
2021-03-10
Structural Design: Review of PR Comments
2021-05-20
EC: Review — Further Review
2021-05-21
-
514Steel studs sizes for non-loadbearing interior wallsThis proposed change is considered an errata as it aims to correct an oversight there was a change in referencing a standard for steel wall framing, between the 2005 and the 2010 NBC. The stud sizes in the appendix note A-9.10.3.1 do not match the intended values.NBC20 Div.B 9.10.3.1.Housing and Small Buildings: Review
2013-04-23
-
456Harmonization of Application of National Model CodesThis proposed change harmonizes the application statements of the National Fire Code and the National Building Code by adding the defined term "alteration" to the National Fire Code and rewording the application statement of the NFC to include the new defined term. NFC20 Div.A 1.1.,
NFC20 Div.A 1.4.1.2.
Hazardous Materials and Activities: Draft
2013-04-17
Hazardous Materials and Activities: Draft
2014-04-07
Review — Deferred
2020-03-27
-
350Slip Resistance on Stairs and RampsProposed change to address Part 3-Part 9 differences for public stairs.NBC20 Div.B 3.4.6.1.(1)Use and Egress: Review — Deferred
2012-12-05
Use and Egress: Review — Deferred
2015-02-19
-
311Door Closers for Use with Swinging DoorsThis proposed change introduces the reference to the ULC-S133, "Tests for Door Closers Intended for Use with Swinging Doors" for self-closing devices on foors in fire separations.NBC20 Div.B 3.1.8.13.,
NBC20 Div.B 9.10.13.10.
Fire Protection: Draft
2013-04-23
357
164Combustible DustThis CCR clarifies the design of systems and structures where combustible dust is produced in quantities or concentrations that create an explosion or fire hazard exist. The proposal replaces Articles 5.3.1.4. through 5.3.1.10. with references to applicable NFPA Standards.NFC20 Div.B 5.3.1.Hazardous Materials and Activities: Review — Deferred
2012-06-13
Hazardous Materials and Activities: Review — Deferred
2016-10-18
674