Once a code change request becomes a minor or CBHCC approved task, it transitions to a proposed change that follows the path outlined in the code development process.

This proposed change tracking database can be used by code change request proponents to follow the progress of proposed changes for a task linked to their code change request. Information in the database can be accessed using the filter option or toggle arrows to sort by:

  • ID number (the number assigned when a code development committee has started its work on the issue and created a proposed change form for potential publication),
  • title,
  • description,
  • code reference,
  • status (the progress of the proposed change through the system), and
  • code change request (the corresponding code change request number assigned when it was originally submitted by a proponent, see the code change request tracking database).

Please direct any questions related to code change requests to CBHCC code change request.

 

IDTitleDescriptionCode ReferenceStatusCode Change Requests
PCF_22192219Section 10.7 Alteration of Existing Plumbing SystemsEstablish requirements for alterations to existing plumbing systems and criteria for determining the extent of alterations and applicable provisions.NBC20 Div.B 10-
PCF_22172217Scope and ApplicationThis proposed change defines Scope and application of a new Section establishing specific requirements to address the unique characteristics of tiny houses.NBC20 Div.B 9.38.-
PCF_22162216Roof load transfer to braced wall panelsThe proposed change addresses the transfer of loads from roof rafters or roof trusses to braced wall panels.NBC20 Div.B 9.23.13.5.-
PCF_22092209Cane detectable barricades on construction sitesThis PCF clarifies the need for cane detectable barricades at construction sitesNBC20 Div.B 8.2.3.3.NMCC on Accessibility: Draft
2026-01-28
PCF_22072207Clarification on the Use of the Term "Fire Watch" Outside Section 5.2. Hot WorkThis proposed change clarifies the use of the term "fire watch" in provisions outside Section 5.2. of Division B of the NFC.NFC20 Div.B 2.8.2.11.,
NFC20 Div.B 2.9.3.4.,
NFC20 Div.B 2.13.2.3.,
NFC20 Div.B 6.1.1.4.(1)
NMCC on Fire and Life Safety: TG/WG Development
2026-01-23
PCF_22062206Welding and Cutting Requirements for Farm BuildingsThis proposed change introduces the requirements of Sentence 3.3.1.26.(1) of Division B of the NBC into Sentence 2.2.8.4.(1).NBC20 Div.B 2.2.8.4.NMCC on Fire and Life Safety: TG/WG Development
2026-01-22
PCF_22042204Power door operators when fire alarm is activatedThe proposed change clarifies how power door operators should be disconnected when fire alarms are activated. NBC20 Div.B 3.4.6.16.NMCC on Accessibility: Draft
2026-01-20
PCF_22032203Minimum number of exits for spaces with doors directly to the exteriorThis proposed change clarifies the number of exits that is required for suites, service rooms, and other spaces at ground level with direct access to the exterior. NBC20 Div.B 3.4.2.1.Draft
2026-01-20
PCF_22022202Visible fire/smoke alarm signals in additional locationsThis PCF proposes to require visible signals for fire alarm systems and smoke alarms in more locations so that people with low/no hearing can get the same information as anyone else. NBC20 Div.B 3.2.4.19.,
NBC20 Div.B 3.2.4.20.,
NBC20 Div.B 9.10.19.
NMCC on Accessibility: Draft
2026-01-07
PCF_21992199New Abbreviations Related to Heating, Ventilating and Air-conditioning Systems - OtherThis proposed change updates the list of symbols and abbreviations in the NBC and NECB.NECB20 Div.A 1.4.2.1.(1)-
PCF_21972197Clarification - Ramps in "cold climates"This PCF clarifies a note about difficulty of navigating ramps in "cold climates" to specify this means wet and icy conditions. NBC20 Div.B 3.8.3.5.NMCC on Accessibility: TG/WG Development
2025-11-20
NMCC on Accessibility: Review
2026-01-09
PCF_21962196Defined TermsThis proposed change introduce new defined terms in the NECB NECB20 Div.A 1.4.1.2.-
PCF_21922192Removing CSA B651 path from 3.8.3.1. and update to CSA B651-23-NBC20 Div.B 3.8.3.1.NMCC on Accessibility: TG/WG Development
2025-11-20
PCF_21912191Ceiling lifts in accessible change spaces-NBC20 Div.B 3.8.NMCC on Accessibility: Draft
2026-01-13
PCF_21902190Signage for accessible change space location-NBC20 Div.B 3.8.NMCC on Accessibility: Draft
2026-01-13
PCF_21892189Option for bilateral toilet in universal washrooms (fold down grab bars)-NBC20 Div.B 3.8.NMCC on Accessibility: Draft
2026-01-13
PCF_21882188Emergency call buttons in universal washrooms-NBC20 Div.B 3.8.NMCC on Accessibility: Draft
2026-01-13
PCF_21872187Accessible change spaces - table properties-NBC20 Div.B 3.8.NMCC on Accessibility: Draft
2026-01-13
PCF_21862186Width of a barrier-free path of travel over long intervals-NBC20 Div.B 3.8.NMCC on Accessibility: Draft
2026-01-13
PCF_21852185Increase width of barrier-free path of travel-NBC20 Div.B 3.8.NMCC on Accessibility: Draft
2026-01-13
PCF_21832183Updates compliance for Subsection 9.36.16.Adds tier 2 prescriptive requirements as a compliance option in Sentence 9.36.16.3.(2)NBC20 Div.B 9.36.-
PCF_21822182Update Modelling Rules for Heat PumpsUpdates modelling rules for heat pumps for reference house and tier 1; adds percent heat loss reduction requirement for tier 1NBC20 Div.B 9.36.5.15.(2),
NBC20 Div.B 9.36.5.16.(1),
NBC20 Div.B 9.36.7.2. Table ,
NBC20 Div.B 9.36.7.3.
-
PCF_21812181Removes base code as a energy performance compliance pathRemoves base code as a compliance path and requires code users to instead comply with energy tier 1NBC20 Div.B 9.36.1.3.-
PCF_21792179Designated Hot Work AreaThis proposed change refines the requirements applicable to a designated area where hot work could be performed without a permit.NBC20 Div.B 3.3.NMCC on Fire and Life Safety: Draft
2025-12-16
PCF_21782178Add Requirements for Energy Storage Systems (ESS) for Part 3 BuildingsThis proposed change introduces requirements to address the potential fire and life safety hazards associated with battery-based energy storage systems (ESS) installed in Part 3 Buildings.NBC20 Div.B 3.6.2.-
PCF_21772177New Defined Term of Energy Storage Systems (ESS)This proposed change introduces a new defined term of Energy Storage Systems (ESS) to NBCNBC20 Div.A 1.4.1.2.(1)-
PCF_21752175Fire Watch (Personnel) and Hot Work Monitoring (Activity)This proposed change defines the required activities for fire monitoring hot works and duties of the fire watch.NFC20 Div.B 5.2.NMCC on Fire and Life Safety: Draft
2025-12-08
PCF_21742174Design of Potable Water Systems per Water Demand Calculator MethodThis proposed change includes a reference to the IAPMO Water Demand Calculator as one of potable water system design guides.NPC20 Div.B 2.6.3.1.(2)-
PCF_21732173Introducing a New Standard CAN/ULC for Plenum RequirementsAdd CAN/ULC S-142. "Standard Method of Fire Test for Heat and Visible Smoke Release for Discrete Products", as a test method for Discrete Stand-Alone Non-Continuous Products Installed in Concealed Spaces Used as Plenums.NBC20 Div.B 3.6.4.3.(1)-
PCF_21722172Intensity-based compliance for operational GHG emissions-NBC20 Div.B 9.36.-
PCF_21702170Intensity-based compliance for operational GHG emissions and energy efficiencyThis proposed change introduces an intensity-based approach in the NECB for complying with operational GHG emissions requirements. It also establishes intensity-based energy targets for retail and warehouse archetypes.NECB20 Div.B 8.4.4.-
PCF_21682168Minimum number of exits for spaces with doors directly to the exteriorThis proposed change clarifies the number of exits that is required for suites, service rooms, and other spaces at ground level with direct access to the exterior. NBC20 Div.B 3.4.2.1.Draft
2025-11-13
PCF_21672167Garages with EV charging stationsThis proposed change introduce requirements for parking garages with EV charging stations.NBC20 Div.B 3.2.4.1.(1)-
PCF_21662166Defined Term of EVThis proposed change introduces defined term "Electric Vehicle (EV)" to Division A of NBC.NBC20 Div.A 1.4.1.2.(1)-
PCF_21622162Add Requirements for Energy Storage Systems (ESS) in Part 9 BuildingsThis proposed change introduces requirements to Part 9 of NBC to address the potential fire and life safety hazards associated with battery-based energy storage systems (ESS).NBC20 Div.B 9.10.9.1.(1),
NBC20 Div.B 9.10.19.3.(1)
NMCC on Fire and Life Safety: Draft
2025-11-04
PCF_21612161Standard for Installation of Fuel Supplies for Heating Equipment and Internal Combustion EnginesThis proposed change adds reference to CAN/CSA B138.1/B138.2-17 (R2022), "Portable Oil Burning Equipment – Packaged Equipment Requirements/Installation Requirements" as an option for installation of heating equipment and internal combustion engines.NFC20 Div.B 5.6.1.10.(1)-
PCF_21602160Active Side Wall Radon StackThis proposed change adds requirements for radon mitigation by use of an optional active side wall radon stack in dwelling units and home-type care occupancies that have a wall, roof or floor assembly in contact with the ground.NBC20 Div.B 9.13.4.Standing Codes Coordination Committee: Review
2025-11-21
NMCC on Indoor Environment: Review — Recommended for Public Review
2026-02-18
PCF_21572157Moving the Reference to CSA A277, "Procedure for certification of prefabricated buildings, modules, and panels," from a Division A Note to a Division C ProvisionThis proposed change permits a certificate to CSA A277, "Procedure for certification of prefabricated buildings, modules, and panels," to be considered as third-party Code compliance approval to facilitate the approval of factory-constructed buildings, modules and panels. NBC20 Div.A 1.1.1.1.,
NBC20 Div.C 2.2.7.5.
Standing Codes Coordination Committee: Review
2025-11-21
NMCC on Housing Supply: Review — Recommended for Public Review
2025-12-11
CBHCC: Pre-Public Review — Proceed
2026-01-22
PCF_21542154INTERNAL ONLY - USED TO EDITORIALLY COMBINE PCF 1475 AND PCF 2048-NBC20 Div.B 9.4.1.1.,
NBC20 Div.B 9.4.2.,
NBC20 Div.B 9.6.1.3.,
NBC20 Div.B 9.20.1.,
NBC20 Div.B 9.23.1.1.,
NBC20 Div.B 9.23.2.,
NBC20 Div.B 9.23.3.1.,
NBC20 Div.B 9.23.3.4.,
NBC20 Div.B 9.23.3.5.,
NBC20 Div.B 9.23.6.1.,
NBC20 Div.B 9.23.11.4.,
NBC20 Div.B 9.23.13.,
NBC20 Div.B 9.23.16.1.,
NBC20 Div.B 9.23.16.5.,
NBC20 Div.B 9.27.5.4.(2),
NBC20 Div.B 9.27.5.4. Table B,
NBC20 Div.B 9.31.6.2.(3),
NBC20 Div.B 9.33.4.7.(2)
-
PCF_21532153Classification of Additional Water Miscible Liquid MixturesThis proposed change provides classification for additional four water-miscible liquid mixtures.NFC20 Div.B 4.1.2.2.Draft
2025-08-20
NMCC on Fire and Life Safety: TG/WG Development
2026-01-20
NMCC on Fire and Life Safety: Review — Recommended for Public Review
2026-02-02
PCF_21512151NBC and NECB 2025 Editorial ChangesThis PCF collects all editorial changes received during the 2025 Code cycle from TAs via email and introduces attribution tables for new Parts.NBC20 Div.B 2.2.1.8.(3),
NBC20 Div.B 3.4.6.8.(8),
NBC20 Div.B 6.3.1.4.(1),
NBC20 Div.B 6.9.2.,
NBC20 Div.B 9.36.1.1.(1),
NBC20 Div.B 9.36.1.3.,
NBC20 Div.B 9.36.2.7.,
NBC20 Div.B 10.1.,
NECB20 Div.B 11,
NECB20 Div.B 13
-
PCF_21482148BERS IT - TEST FILETest test test test test test test test test test test test test test test test test test test test test test test test test test test test test test test test test test test test test testNBC20 Div.B 3.2.2.2.(1),
NBC20 Div.B 3.2.2.1.(1),
NBC20 Div.B 9.36.11.
NMCC on Performance-Based Solutions: Draft
2025-11-01
PCF_21472147Door hardware in door clear width considerationsClarification of explanatory note on clear width of doorways in relation to door hardwareNBC20 Div.B 3.8.3.6.(2)NMCC on Accessibility: Draft
2025-06-27
PCF_21462146Door hardware in door clear width considerationsThis PCF clarifies wording around door closers and exit devices and how they are considered for the clear width of doorwaysNBC20 Div.B 3.8.3.6.(2)-
PCF_21452145Update Classification of Water Miscible Liquid MixturesThis proposed change updates the testing method and the classification of water miscible liquid mixtures (WMLMs) in NFC.NFC20 Div.B 4.1.2.1.,
NFC20 Div.B 4.1.2.2.
NMCC on Fire and Life Safety: Draft
2025-07-17
NMCC on Fire and Life Safety: TG/WG Development
2026-01-20
NMCC on Fire and Life Safety: Review — Recommended for Public Review
2026-02-02
PCF_21412141Requirements for Circuit Venting in NPC This proposed change includes consistent fixture units to be referenced for stack within Article 2.5.3.1. and Figure A-2.5.3.1.-E Example 2NPC20 Div.B 2.5.3.1.-
PCF_21402140Requirements for the Upper Design Supply Temperature of Hydronic Heating SystemsThis proposed change includes requirements for an upper limit to the allowable design supply temperature of hydronic heating systems in NECB Articles 5.2.1.1., 5.4.1.2. and 8.4.4.9. NECB20 Div.B 5.2.1.1.,
NECB20 Div.B 5.4.1.2.,
NECB20 Div.B 8.4.4.9.
-
PCF_21382138Requirements for Floor Drains in NBC Part 3 and 9 BuildingsThis proposed change includes consistent requirements for floor drains, to be provided in Sentences 3.7.2.6.(1) and proposed (2) to (4), proposed Note A-3.7.2.6.(4), Table 3.10.1.1., Sentences 9.31.4.3.(1) and 9.35.2.2.(1), and Note A-9.35.2.2.(1), and Article 9.37.1.1. of Division B of NBCNBC20 Div.B 3.7.2.6.,
NBC20 Div.B 9.31.4.3.,
NBC20 Div.B 9.35.2.2.,
NBC20 Div.B 9.37.1.1.
-
PCF_21372137 Installation of a Backwater Valve for Plumbing Fixtures Located Below the Upstream Sanitary ManholeThis proposed change clarifies requirements for the installation of a backwater valve to protect plumbing fixtures from backflow.NPC20 Div.B 2.4.6.4.TG/WG Development
2025-11-03
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Deferred
2026-01-22
TG/WG Development
2026-02-04
CBHCC: Pre-Public Review — Proceed
2026-02-23
PCF_21332133Requirements for Installation of Drainage Piping Without DepressionsThe proposed changes introduce requirements for drainage piping to be installed without depressions where accumulation may collect.NPC20 Div.B 2.4.1.1.-
PCF_21322132Requirements for Maximum Cleanout Distance Interval in Vertical Pipes of a Drainage SystemThis proposed change includes requirements for cleanout and access at maximum distance interval for vertical sink wastes.NPC20 Div.B 2.4.7.2.-
PCF_21312131Requirements for the Minimum Number of Baffles in a Grease InterceptorThis proposed change includes requirements for the minimum number of baffles in a grease interceptor in Article 2.5.5.2.NPC20 Div.B 2.5.5.2.Draft
2026-03-17
PCF_21302130Connections to Sanitary Drainage Systems with different Devices Clarify termination requirements for device connections to sanitary drainage systems, including air gaps for indirect drainage to prevent backflow and protect potable water.NPC20 Div.B 2.4.2.1.(1)TG/WG Development
2026-02-17
PCF_21292129Clarification of numbers of stalls and urinals for people with limited mobilityThis PCF clarifies how to interpret the requirements for numbers of required stalls for people with limited mobility. NBC20 Div.B 3.8.2.8.,
NBC20 Div.B 3.7.2.2.
NMCC on Accessibility: TG/WG Development
2025-09-16
NMCC on Accessibility: TG/WG Development
2025-11-20
PCF_21282128Separation from Other Dangerous GoodsThis proposed change update the separation table for the storage of dangerous goods and controlled products.NFC20 Div.B 3.2.7.6.NMCC on Fire and Life Safety: TG/WG Development
2025-08-13
PCF_21272127Accessible change spaces in B3 occupancies (care occupancy)This proposed change requires at least one accessible change space in care occupancy buildings. These can be part of universal washrooms. NBC20 Div.B 3.8.2.8.-
PCF_21252125Accessible fitting roomsThis PCF proposes to require that where fitting rooms are provided (ex: in a clothing store), at least one should be accessible. NBC20 Div.B 3.8.2.3.Draft
2025-03-07
PCF_21232123Removal of the term "ambulatory"The PCF proposes to remove the reference to "ambulatory" in describing the building's occupants, as it is not a defined and set state of being. NBC20 Div.B 3.1.2.5.,
NBC20 Div.B 3.3.1.7.,
NBC20 Div.B 9.10.2.2.
Draft
2025-01-24
PCF_21222122Clarifying what "Pedestrian Entrance" MeansThis proposed change explains what a "pedestrian entrance" means for accessibility purposes.NBC20 Div.B 3.8.2.2.Draft
2025-01-24
PCF_21202120Updating the Defined Term "Barrier-free"This proposed change revises the definition of the term "barrier-free", the associated objectives and functional statements to align with current legislation, standards and other codes. NBC20 Div.A 1.4.1.2.,
NBC20 Div.A 2.2.1.1.,
NBC20 Div.A 3.2.1.1.(1)
Draft
2025-01-17
PCF_21162116Introducing a New Standard ANSI/CAN/UL/ULC 2152 for Special Purpose Nonmetalic ContainersThis request is to add ANSI/CAN/UL/ULC 2152, “Safety for Special Purpose Nonmetallic Containers and Tanks for Specific Combustible or Noncombustible Liquids” standard to allow the use of special purpose nonmetalic containers and tanks for combustible or noncombustible liquids.NFC20 Div.B 4.3.1.2.(1)-
PCF_21122112Introducing a New Standard ANSI/CAN/UL/ULC 1369:2020 for Aboveground PipingAdd Standard ANSI/CAN/UL/ULC 1369:2020, "Aboveground Piping for Flammable and Combustible Liquids," to ensure conformance of metallic and nonmetallic piping systems used in aboveground installations.NFC20 Div.B 4.5.2.1.(3)TG/WG Development
2026-02-09
PCF_21092109Fan Motor Power Threshold for the Application of Prescriptive RequirementsThis proposed change lowers the threshold for total fan motor power for the application of prescriptive requirements.NECB20 Div.B 5.2.3.1.Energy Efficiency: Review — Recommended for Public Review
2024-12-18
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
PCF_21082108Revision of Attributions and Intent Statements in Division B of NBCRevise attributions and intent statements in Division B of the NBC following an assessment of the provisions, intents, relevant objectives and functional statements.NBC20 Div.B 2.2.1.14.(1),
NBC20 Div.B 2.2.1.15.(2),
NBC20 Div.B 2.2.3.3.(1),
NBC20 Div.B 2.2.3.7.(2),
NBC20 Div.B 2.2.6.5.(2),
NBC20 Div.B 2.2.6.9.(1),
NBC20 Div.B 2.2.8.3.(2),
NBC20 Div.B 2.2.8.3.(3),
NBC20 Div.B 2.2.8.3.(4),
NBC20 Div.B 3.1.6.3.(3),
NBC20 Div.B 3.1.6.4.(1),
NBC20 Div.B 3.1.6.4.(2),
NBC20 Div.B 3.1.6.5.(1),
NBC20 Div.B 3.1.6.9.(1),
NBC20 Div.B 3.1.9.4.(7),
NBC20 Div.B 3.1.11.5.(4),
NBC20 Div.B 3.2.3.7.(3),
NBC20 Div.B 3.2.3.7.(4),
NBC20 Div.B 3.2.7.1.(1),
NBC20 Div.B 3.2.7.1.(2),
NBC20 Div.B 3.2.7.3.(1),
NBC20 Div.B 3.2.7.3.(2),
NBC20 Div.B 3.2.7.3.(3),
NBC20 Div.B 3.2.7.3.(4),
NBC20 Div.B 3.2.7.4.(1),
NBC20 Div.B 3.2.7.4.(2),
NBC20 Div.B 3.2.7.7.(1)
Hazardous Materials and Activities: Draft
2024-10-15
PCF_21072107Revision of Attributions and Intent Statements in Division B of NFCRevise attributions and intent statements in Division B of the NFC following an assessment of the provisions, intents, relevant objectives and functional statements.NFC20 Div.B 2.8.2.1.(3),
NFC20 Div.B 2.14.1.1.(4),
NFC20 Div.B 2.14.2.1.(1),
NFC20 Div.B 3.3.2.10.(1),
NFC20 Div.B 4.3.7.4.(1),
NFC20 Div.B 4.4.1.2.(6),
NFC20 Div.B 4.5.6.10.(1),
NFC20 Div.B 4.12.1.2.(1),
NFC20 Div.B 4.12.1.2.(3),
NFC20 Div.B 4.12.1.3.(1),
NFC20 Div.B 5.6.3.4.(1),
NFC20 Div.B 5.6.4.2.(5)
-
PCF_21052105Change SCOP to "Net Sensible COP" in Table 5.2.12.1.-H as the Metric Used for Computer Room Air ConditionersThis proposed change replaces the minimum performance metric "sensible coefficient of performance (SCOP)" with the "net sensible COP (NSenCOP)" in Table 5.2.12.1.-H to harmonize with the metric used in AHRI 1360 (I-P), AHRI 1361 (SI) and ANSI/ASHRAE/IES 90.1-2022.NECB20 Div.B 5.2.12.1. Table HEnergy Efficiency: Review — Recommended for Public Review
2025-11-18
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
PCF_21022102Removal of a withdrawn ASTM StandardThis proposed change deletes the reference to the standard ASTM C1053, “Standard Specification for Borosilicate Glass Pipe and Fittings for Drain, Waste, and Vent (DWV) Applications,” that was withdrawn.NPC20 Div.B 2.2.8.1.HVAC and Plumbing: Review — Withdrawn
2024-12-03
PCF_21012101Fibrocement pipe and fittingsThis proposed change prohibits the use of fibrocement pipes an fittings to covey sewage. NPC20 Div.B 2.2.5.-
PCF_21002100Direct Flush ValvesThis proposed change eliminates duplicated requirements for direct flush valves by only keeping the referenced standards.NPC20 Div.B 2.2.10.8.-
PCF_20972097Adding FS-OS attribution to the Part 2 of NBC 2025This proposed change aims to add FS-OS attribution to Subsection 2.2.2. of NBC 2020, ensuring consistency with other Parts of NBC 2025.NBC20 Div.B 2.2.2.,
NBC20 Div.B 3.1.16.1.
Draft
2024-10-15
PCF_20952095Explanatory Notes on impact of thermal insulation on fire performance of envelope assemblies and cladding support This proposed change adds explanatory Notes to raise awareness of the impact of increased thermal insulation on fire resistive performance of envelope assemblies and structural support for cladding. NBC20 Div.B 9.25.2.1.,
NBC20 Div.B 9.27.5.1.
Standing Codes Coordination Committee: Review
2025-11-21
PCF_20902090Reference to the CSA-Z32, "Electrical Safety and Essential Electrical Systems in Health Care Facilities"This proposed change clarifies the application of the referenced standard CSA-Z32, "Electrical Safety and Essential Electrical Systems in Health Care Facilities" in both NBC and NFC.NBC20 Div.B 3.2.7.5.,
NBC20 Div.B 3.2.7.6.,
NFC20 Div.B 6.5.1.1.
Use and Egress: Draft
2024-07-05
PCF_20892089Clear Floor Space on the Non-Latch Side of Sliding DoorsThis proposed change expands the application of a clear floor space to either sides of a sliding door in a barrier-free path of travel.NBC20 Div.B 3.8.3.6.Use and Egress: Draft
2024-07-04
PCF_20882088Clarify the Intent of "Clear Floor Space" in Barrier-Free DesignThis proposed change clarifies the intent behind the reference to "clear floor space" when used in barrier-free design.NBC20 Div.B 3.3.2.8.,
NBC20 Div.B 3.8.
Use and Egress: Draft
2024-06-26
PCF_20862086Reference the individual standards within the CSA B108:23 packageReference individual standards CSA B108.1:23, "Compressed natural gas refuelling stations installation code" and CSA B108.2:23, "Liquefied natural gas refuelling stations installation code" within the CSA B108:23 Package.NFC20 Div.B 4.6.1.1.(2)Hazardous Materials and Activities: Review
2024-08-21
Hazardous Materials and Activities: Review — Recommended for Public Review
2024-10-25
PCF_20852085Replace Existing ULC/ORD-C842-84 and CAN/ULC-S651:2016 with ANSI/CAN/UL/ULC 842:2020This proposed change replaces the reference to ULC/ORD-C842-84, "Guide for the Investigation of Valves for Flammable and Combustible Liquids," and CAN/ULC-S651:2016, "Standard for Emergency Valves for Flammable and Combustible Liquids," with a reference to ANSI/CAN/UL/ULC 842:2020, “Standard for Valves for Flammable and Combustible Liquids."NFC20 Div.B 4.5.7.1.(1),
NFC20 Div.B 4.5.7.1.(3),
NFC20 Div.B 4.6.6.3.(1)
Hazardous Materials and Activities: Review
2024-05-22
Hazardous Materials and Activities: Review — Recommended for Public Review
2024-08-21
PCF_20812081Replace Existing ULC/ORD C107.21-92 with CAN/ULC S664:2017 This proposed change replaces the reference to ULC/ORD C107.21-92, “Under Dispenser Sumps," with a reference to CAN/ULC S664:2017, "Standard for Containment Sumps, Sump fittings, and Accessories for Flammable and Combustible Liquids"NFC20 Div.B 4.6.3.2.(1)Hazardous Materials and Activities: Review
2024-05-22
Hazardous Materials and Activities: Review — Recommended for Public Review
2024-08-21
PCF_20802080Replace Existing CAN/ULC-S612:2016 with ANSI/CAN/UL 330:2024This proposed change replaces the reference to CAN/ULC-S612:2016, “Standard for Hose and Hose Assemblies for Flammable and Combustible Liquids," with a reference to ANSI/CAN/UL 330:2024, “Standard for Hose and Hose Assemblies for Dispensing Flammable and Combustible Liquids."NFC20 Div.B 4.6.5.1.(1)Hazardous Materials and Activities: Review
2024-05-22
Hazardous Materials and Activities: Review — Recommended for Public Review
2024-08-21
PCF_20792079"Thermal Bridge"This proposed change introduces the defined term "thermal bridge" in the NBC and the NECB.NBC20 Div.A 1.4.1.2.,
NECB20 Div.A 1.4.1.2.
Energy Efficiency: Draft
2024-07-11
PCF_20782078Replace Existing CAN/ULC-S620:2016 with ANSI/CAN/UL/ULC 2586:2022This proposed change replaces the reference to CAN/ULC-S620:2016, "Standard for Hose Nozzle Valves for Flammable and Combustible Liquids," with a reference to ANSI/CAN/UL/ULC 2586:2022, “Standard for Hose Nozzle Valves."NFC20 Div.B 4.5.7.1.(2),
NFC20 Div.B 4.6.5.2.(1)
Hazardous Materials and Activities: Review
2024-05-22
Hazardous Materials and Activities: Review — Recommended for Public Review
2024-08-21
PCF_20772077Replace Existing CAN/ULC-S615-14 with ANSI/CAN/UL/ULC 1316:2018This proposed change replaces the reference to CAN/ULC-S615-14, "Standard for Fibre Reinforced Plastic Underground Tanks for Flammable and Combustible Liquids," with a reference to ANSI/CAN/UL/ULC 1316:2018, “Standard for Fibre Reinforced Underground Tanks for Flammable and Combustible Liquids."NFC20 Div.B 4.3.1.2.(1),
NFC20 Div.B 4.3.8.6.(2),
NFC20 Div.B 4.4.3.2.(4)
Hazardous Materials and Activities: Review
2024-05-22
Hazardous Materials and Activities: Review — Recommended for Public Review
2024-08-21
PCF_20762076Replace Existing CAN/ULC-S661-10 and CAN/ULC-S663-11 with ANSI/CAN/UL/ULC 2583:2021This proposed change replaces the reference to CAN/ULC-S661-10, “Standard for Overfill Protection Devices for Flammable and Combustible Liquid Storage Tanks," and CAN/ULC-S663-11, "Standard for Spill Containment Devices for Flammable and Combustible Liquid Aboveground Storage Tanks," with a reference to ANSI/CAN/UL/ULC 2583:2021, “Standard for Fuel Tank Accessories for Flammable and Combustible Liquids."NFC20 Div.B 4.3.1.8.(1),
NFC20 Div.B 4.3.1.8.(2),
NFC20 Div.B 4.3.6.4.(4)
Hazardous Materials and Activities: Review
2024-05-22
Hazardous Materials and Activities: Review — Recommended for Public Review
2024-08-21
PCF_20732073Replace Existing CSA B306-M1977 to CSA B306:23This proposed change replaces the reference to CSA B306-M1977, "Portable Fuel Tanks for Marine Use," to a reference to CSA B306:23, “Portable engine fueling system for marine use."NFC20 Div.B 4.2.3.1.(1)Hazardous Materials and Activities: Review — Recommended for Public Review
2024-08-21
PCF_20722072Replace Existing CAN/ULC-S633:2017 with ANSI/CAN/UL/ULC 2039:2023This proposed change replaces the reference to CAN/ULC-S633:2017, "Standard for Flexible Connector Piping for Fuels," with a reference to ANSI/CAN/UL/ULC 2039:2023, “Standard for Flexible Connector Piping for Flammable and Combustible Liquids."NFC20 Div.B 4.5.6.14.(2)Hazardous Materials and Activities: Review
2024-05-22
Hazardous Materials and Activities: Review — Recommended for Public Review
2024-08-21
PCF_20652065Replace Existing ULC/ORD-C30-95 to ANSI/CAN/UL/ULC 30:2022This proposed change replaces the reference to ULC/ORD-C30-95, "Safety Containers,” to a reference to ANSI/CAN/UL/ULC 30:2022, "Standard for Metallic and Nonmetallic Safety Cans for Flammable and Combustible Liquids."NFC20 Div.B 4.1.5.8.(2),
NFC20 Div.B 4.2.3.1.(1),
NFC20 Div.B 4.2.6.4.(1),
NFC20 Div.B 5.5.5.2.(2)
Hazardous Materials and Activities: Review — Recommended for Public Review
2024-05-22
PCF_20642064Replace Existing ULC/ORD-C1275-84 to ANSI/CAN/UL/ULC 1275:2024This proposed change replaces the reference to ULC/ORD-C1275-84, “Guide for the Investigation of Storage Cabinets for Flammable Liquid Containers," to a reference to ANSI/CAN/UL/ULC 1275:2024, “Standard for Flammable Liquid Storage Cabinets."NFC20 Div.B 4.2.10.5.(1)Hazardous Materials and Activities: Review — Recommended for Public Review
2024-05-22
Hazardous Materials and Activities: Review — Recommended for Public Review
2024-08-21
PCF_20612061Overheating in New Dwelling Units This proposed change requires new dwelling units to be provided with mechanical cooling in locations where the outside summer design temperature exceeds 26°C.NBC20 Div.B 1.1.3.1.,
NBC20 Div.B 6.2.1.,
NBC20 Div.B 9.33.2.1.,
NBC20 Div.B 9.33.3.,
NBC20 Div.B 9.33.5.
Housing and Small Buildings: TG/WG Development
2024-02-28
Housing and Small Buildings: TG/WG Development
2024-03-14
Housing and Small Buildings: TG/WG Development
2024-04-03
Housing and Small Buildings: Review — Recommended for Public Review
2024-04-09
HVAC and Plumbing: Review — Recommended for Public Review
2024-04-15
Use and Egress: Review
2024-04-16
SC Div AC: Pre-Public Review
2024-04-22
Earthquake Design: Review
2024-04-23
Energy Efficiency: Review
2024-04-24
Structural Design: Review
2024-04-24
Environmental Separation: Review
2024-04-24
Fire Protection: Review
2024-04-24
Hazardous Materials and Activities: Review
2024-04-29
Housing and Small Buildings: Review
2024-04-29
SC Div AC: Review — Recommended for Public Review
2024-04-29
CBHCC: Pre-Public Review — Proceed
2024-04-30
Energy Efficiency: Review
2024-06-06
Housing and Small Buildings: Review of PR Comments
2024-09-04
Housing and Small Buildings: Review
2024-09-11
Housing and Small Buildings: TG/WG Development
2024-09-17
Use and Egress: Review of PR Comments
2024-09-18
Housing and Small Buildings: TG/WG Development
2024-09-26
HVAC and Plumbing: Review
2024-10-03
Housing and Small Buildings: Analysis of PR Comments — Recommend to proceed with technical revisions
2024-10-09
Housing and Small Buildings: TG/WG Development
2024-10-11
Housing and Small Buildings: Review of PR Comments — Proceed with technical revisions
2024-10-23
SC Div AC: Review of PR Comments — Proceed as proposed —
2024-10-29
Housing and Small Buildings: Review of PR Comments — Proceed with technical revisions
2024-10-29
Housing and Small Buildings: Review of PR Comments
2024-11-13
Housing and Small Buildings: Review of PR Comments — Resubmit for Public Review
2024-11-21
HVAC and Plumbing: Review of PR Comments — Proceed with technical revisions
2024-11-25
CBHCC: Review of PR Comments — Resubmit for Public Review
2024-12-05
PCF_20572057Energy Modeling Software RequirementsThis proposed change updates the ANSI/ASHRAE Standard 140, 'Method of Test for Evaluating Building Performance Simulation Software' to its 2023 edition and adds a new Article on acceptance criteria for energy modeling software.NBC20 Div.B 9.36.5.4.(8),
NBC20 Div.B 9.36.5.,
NBC20 Div.B 9.36.2.4.(4),
NBC20 Div.B 9.36.7.3.(5),
NBC20 Div.B 9.36.5.3.(1),
NBC20 Div.B 9.36.5.15.(6),
NBC20 Div.B 9.36.7.3.(4)
Energy Efficiency: Review
2024-06-06
Energy Efficiency: Review — Withdrawn
2024-06-06
Standing Codes Coordination Committee: Review
2025-11-21
PCF_20542054Clarification of Installation Location for Accessible ControlsThis proposed change clarifies that the prescribed height range for accessible controls should be determined in relation to the finished floor and the centre line of the controls.NBC20 Div.B 3.8.3.8.(1)Use and Egress: Draft
2024-05-10
Use and Egress: Review — Further Review
2024-06-05
NMCC on Accessibility: Review — Recommended for Public Review
2025-05-16
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
PCF_20532053Update to CSA B651 references in NBC (if CSA B651-23 is adopted)If CSA B651-23 is adopted in the next edition of the NBC, several clause numbers need to be updated. This is an editorial update.NBC20 Div.B 3.3.1.19.,
NBC20 Div.B 3.8.3.
Use and Egress: Draft
2024-01-10
PCF_20502050Egress Windows or Doors for Bedrooms in Part 3 Residential BuildingsThe proposed change requires egress window or door from bedrooms in Group C, Part 3 buildings that are not sprinklered.NBC20 Div.B 3.3.4.Use and Egress: Draft
2023-12-13
PCF_20492049Specified Wind and Snow Loads in Part 9-NBC20 Div.B 9.4.2.2.-
PCF_20472047Performance Path -NECB20 Div.B 13.8.-
PCF_20462046Update to Table 3.8.3.1. for CSA B651 reference to signageProvide an accurate reference in Table 3.8.3.1. to reflect the relocation of some provisions made in the CSA B651-18 standard. NBC20 Div.B 3.8.3.1.Use and Egress: Draft
2023-11-28
Use and Egress: Review — Editorial Revision/Errata (No Public Review)
2023-12-18
PCF_20452045Tier 4 Prescriptive RequirementsThis proposed change provides the energy efficiency requirements for compliance with tier 4 of the energy performance compliance prescriptive path.NBC20 Div.B 9.36.-
PCF_20442044Tier 3 Prescriptive RequirementsThis proposed change provides the energy efficiency requirements for compliance with tier 3 of the energy performance compliance prescriptive path.NBC20 Div.B 9.36.-
PCF_20432043Tiered Energy Compliance: Tier 2 Prescriptive PathThis proposed change provides energy-efficiency requirements for compliance with Energy Performance Tier 2 of the energy performance compliance prescriptive path.NBC20 Div.B 9.36.11.NMCC on Climate Change Mitigation: Review — Recommended for Public Review
2025-11-18
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
PCF_20382038Application of Automatic Sprinkler Systems and NFPA 13RThis proposed change clarifies the application of NFPA 13R, "Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies," for mixed occupancies.NBC20 Div.B 3.2.5.12.Fire Protection: TG/WG Development
2024-07-31
Fire Protection: Review
2024-09-03
Fire Protection: TG/WG Development
2024-11-18
Fire Protection: Review — Recommended for Public Review
2024-11-27
NMCC on Fire and Life Safety: Review — Recommended for Public Review
2025-09-15
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
PCF_20332033Ventilation Systems in Existing Buildings Subjected to AlterationThis proposed change introduces requirements for ventilation systems in existing buildings subjected to alteration.NBC20 Div.B 10.9.Energy Efficiency: Review
2023-09-27
Housing and Small Buildings: Review
2023-12-06
Housing and Small Buildings: Review — Recommended for Public Review
2024-02-08
CBHCC: Pre-Public Review — Proceed
2024-04-30
Housing and Small Buildings: Review of PR Comments
2024-09-11
PCF_20292029Accessible Menstrual Product Dispensers: Control DesignThis proposed change requires accessible control designs for menstrual product dispensers where such dispensers are provided so that they may be accessed by persons with disabilities related to dexterity.NBC20 Div.B 3.8.3.16.Use and Egress: Draft
2023-09-14
NMCC on Accessibility: Review — Recommended for Public Review
2025-05-16
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
PCF_20232023Fire and Sound Resistance Table UpdatesThe proposed change updates the description of the external wall assembly EW2 and EW3, and associated Table Notes.NBC20 Div.B 9.10.3.1. Table ANMCC on Fire and Life Safety: Draft
2025-07-16
PCF_20222022Clarification of OS Safety Sub-Objective for Firefighter SafetyThis proposed change distinguishes firefighters when performing their duties from the "persons" in the definition of sub-objective OS1 Fire Safety.NPC20 Div.A 2.2.1.1.(1)-
PCF_20212021Application of Accessibility Requirements to Dwelling UnitsThis proposed change revises the application of Section 3.8. exempting dwelling units from accessibility requirements.NBC20 Div.B 3.8.2.1.Use and Egress: TG/WG Development
2023-08-25
PCF_20202020Reference House Modeling of Service Water Heating equipment not listed in Table 9.36.4.2This proposed change closes a loophole where the requirements in Table 9.36.5.16 were not aligned with Table 9.36.4.2NBC20 Div.B 9.36.5.16.Energy Efficiency: Draft
2023-08-09
PCF_20192019Reference House Modeling of HVAC equipment not addressed in Table 9.36.3.10.This proposed change closes a loophole where the requirements in Clause 9.36.5.15.(7)(b) were not aligned with Table 9.36.3.10 in NBC 2020.NBC20 Div.B 9.36.5.15.Energy Efficiency: Draft
2023-08-04
PCF_20152015Defined Term of DistilleryThis proposed change suggested to revise the defined term "Distillery" to avoid confusion between the property and the building on the property.NBC20 Div.A 1.4.1.2.(1)Hazardous Materials and Activities: Draft
2023-07-31
PCF_20142014Replacing the Term "Fixture" with "Plumbing Fixture"This change identified all instances where the term "fixture(s)'' is used in the NPC 2020 and replace it with "plumbing fixture(s)" where necessary. NPC20 Div.B 2.1.3.,
NPC20 Div.B 2.1.3.2.(1),
NPC20 Div.B 2.2.2.,
NPC20 Div.B 2.2.3.1.(2),
NPC20 Div.B 2.2.3.1.(5),
NPC20 Div.B 2.2.10.8.(1),
NPC20 Div.B 2.3.3.4.(2),
NPC20 Div.B 2.3.3.8.,
NPC20 Div.B 2.3.3.11.(1),
NPC20 Div.B 2.3.3.11.(2),
NPC20 Div.B 2.3.4.1.(2),
NPC20 Div.B 2.3.4.2.(1),
NPC20 Div.B 2.3.6.1.(1),
NPC20 Div.B 2.3.6.1.(2),
NPC20 Div.B 2.3.7.3.(1),
NPC20 Div.B 2.4.2.1.(1),
NPC20 Div.B 2.4.2.1.(2),
NPC20 Div.B 2.4.2.1.(3),
NPC20 Div.B 2.4.2.3.(1),
NPC20 Div.B 2.4.2.3.(2),
NPC20 Div.B 2.4.2.3.(3),
NPC20 Div.B 2.4.3.,
NPC20 Div.B 2.4.3.4.(1),
NPC20 Div.B 2.4.4.1.(1),
NPC20 Div.B 2.4.4.2.(1),
NPC20 Div.B 2.4.4.3.,
NPC20 Div.B 2.4.4.4.(1),
NPC20 Div.B 2.4.5.1.,
NPC20 Div.B 2.4.6.4.,
NPC20 Div.B 2.4.7.4.(5),
NPC20 Div.B 2.4.9.3. Table ,
NPC20 Div.B 2.4.10.1.(1),
NPC20 Div.B 2.4.10.2.,
NPC20 Div.B 2.4.10.3.,
NPC20 Div.B 2.4.10.12.,
NPC20 Div.B 2.5.2.1.(1),
NPC20 Div.B 2.5.3.1.(1),
NPC20 Div.B 2.5.3.1.(2),
NPC20 Div.B 2.5.3.1.(3),
NPC20 Div.B 2.5.3.1.(5),
NPC20 Div.B 2.5.3.1.(6),
NPC20 Div.B 2.5.3.1.(11),
NPC20 Div.B 2.5.4.2.,
NPC20 Div.B 2.5.4.3.,
NPC20 Div.B 2.5.4.5.,
NPC20 Div.B 2.5.5.5.,
NPC20 Div.B 2.5.6.3.,
NPC20 Div.B 2.5.6.4.,
NPC20 Div.B 2.5.8.1.(2),
NPC20 Div.B 2.5.8.1. Table ,
NPC20 Div.B 2.5.9.2.(1),
NPC20 Div.B 2.6.1.1.(1),
NPC20 Div.B 2.6.1.3.(6),
NPC20 Div.B 2.6.1.6.,
NPC20 Div.B 2.6.2.2.(1),
NPC20 Div.B 2.6.2.3.(1),
NPC20 Div.B 2.6.2.10.(2),
NPC20 Div.B 2.6.2.10.(3),
NPC20 Div.B 2.6.2.10.(4),
NPC20 Div.B 2.6.3.2.,
NPC20 Div.B 2.6.3.3.(1),
NPC20 Div.B 2.6.3.4.,
NPC20 Div.B 2.7.1.1.(5),
NPC20 Div.B 2.7.1.4.(1),
NPC20 Div.B 2.7.2.4.(5),
NPC20 Div.B 2.7.2.4.(10),
NPC20 Div.B 2.2.10.6.(2),
NPC20 Div.B 2.2.10.7.,
NPC20 Div.B 2.4.5.1.(3),
NPC20 Div.B 2.4.5.1.(5),
NPC20 Div.B 2.4.8.2.(1),
NPC20 Div.B 2.4.10.,
NPC20 Div.B 2.5.3.1.,
NPC20 Div.B 2.5.4.5.(1),
NPC20 Div.B 2.5.6.3.(1),
NPC20 Div.B 2.5.6.3.(2),
NPC20 Div.B 2.6.1.3.(5),
NPC20 Div.B 2.6.3.1.(2),
NPC20 Div.B 2.6.3.4.(5)
HVAC and Plumbing: Review — Recommended for Public Review
2023-10-12
HVAC and Plumbing: Review — Withdrawn
2023-10-31
PCF_20122012Indoor Design Temperatures for Residential Buildings-NBC20 Div.B 6.2.1.1.HVAC and Plumbing: Review
2023-09-13
HVAC and Plumbing: Review
2023-11-22
PCF_20072007Lavatory Supply Fittings in Public WashroomsThis proposed change adds a Note to Sentence 3.7.2.3.(4) of the NBC to direct Code users to Article 2.2.10.6. of the NPC for requirements for lavatory supply fittings in public washrooms.NPC20 Div.B 2.2.10.6.,
NBC20 Div.B 3.7.2.3.
HVAC and Plumbing: Review — Recommended for Public Review
2023-09-13
CBHCC: Pre-Public Review — Proceed
2024-04-30
HVAC and Plumbing: Review of PR Comments — Proceed as proposed —
2024-06-19
CBHCC: Post-Public Review — Deferred
2025-04-23
NMCC on Indoor Environment: Review — Further Review
2025-06-10
NMCC on Indoor Environment: Review — Recommended for Public Review
2025-11-04
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
PCF_19981998Introduction of New OS Safety Sub-Objective for Firefighter SafetyThis proposed change adds a new sub-objective OS6 Firefighter Safety that clarifies which existing requirements are intended to address firefighter safety by distinguishing firefighters from the "persons" in the definition of sub-objective OS1 Fire Safety. NBC20 Div.A 2.2.1.1.(1),
NFC20 Div.A 2.2.1.1.(1)
CBHCC: Draft
2023-06-27
Environmental Separation: Review
2023-08-29
Energy Efficiency: Review
2023-09-01
Earthquake Design: Review
2023-09-07
Hazardous Materials and Activities: Review
2023-09-08
Review
2023-09-08
HVAC and Plumbing: Review
2023-09-11
Fire Protection: Review
2023-09-14
Structural Design: Review
2023-09-20
Housing and Small Buildings: Review
2023-09-26
Use and Egress: Review
2023-09-26
Fire Protection: Review
2023-10-03
Housing and Small Buildings: Review
2023-10-03
Housing and Small Buildings: Review
2023-11-01
CBHCC: Review
2024-01-24
CBHCC: Pre-Public Review — Proceed
2024-04-30
CBHCC: CBHCC Decision
2024-10-03
PCF_19921992palce holder for 13.8-NECB20 Div.B 13.8.-
PCF_19871987Outpatient ClinicsNew requirements related to operation of outpatient clinics.NFC20 Div.B 2.1.2.2.,
NFC20 Div.B 2.8.1.2.
-
PCF_19861986Outpatient ClinicsNew requirements related to construction of outpatient clinics.NBC20 Div.B 3.2.7.4.,
NBC20 Div.B 3.2.7.8.
-
PCF_19851985Outpatient ClinicsSignpost to Part 3 from Part 9NBC20 Div.B 9.10.1.3.-
PCF_19841984Outpatient ClinicsNew requirements related to construction of outpatient clinics.NBC20 Div.B 3.3.-
PCF_19831983Introduce Testing Standards for Air Barriers for Roof AssembliesThis proposed change introduces two testing standards to the NECB for air leakage through roof assemblies.NECB20 Div.B 3.2.4.3.-
PCF_19821982Outpatient ClinicsThe proposed change introduces a new defined term for outpatient clinics.NBC20 Div.A 1.4.1.2.-
PCF_19661966Withdrawing the flexibility in designation of a structure as regular from earthquake design perspectiveThis proposed change deletes the Sentence 4.1.8.6.(2) which permits that a structure which does not have any of the irregularities specified in the NBC may be considered as regular. NBC20 Div.B 4.1.8.6.-
PCF_19611961Plumbing for adaptable washroom sinksThis PCF introduces new requirements for plumbing in washroom sinks to reduce the expense of lowering the height for use by wheelchair usersNBC20 Div.B 3.8.HVAC and Plumbing: Review
2023-10-12
PCF_19561956Plumbing for adaptable kitchensThis PCF introduces new requirements for plumbing in kitchens to reduce the expense of adapting the space for use by wheelchair usersNBC20 Div.B 3.8.Use and Egress: Draft
2023-05-23
Housing and Small Buildings: Review
2023-05-31
Use and Egress: Review
2023-06-07
Use and Egress: Review
2023-07-14
Use and Egress: TG/WG Development
2023-07-24
Use and Egress: Review
2023-08-22
Use and Egress: TG/WG Development
2023-09-27
HVAC and Plumbing: Review
2023-10-12
PCF_19551955Clarification of span limitation for wood-frame constructionThis proposed change intends to clarify that the limitation for the span of any structural member not to exceed 12.20 m in wood-frame construction refers to the clear span.NBC20 Div.B 9.23.1.1.(1)-
PCF_19531953Clarification of requirement for panel-type underlay beneath adhesive-applied ceramic tileThis proposed change seeks to clarify the requirement for panel-type underlay to be provided under ceramic tile applied with adhesive per 9.30.2.1.(3), in addition to the subfloor having its edges supported per 9.30.6.1.(2) (i.e. ceramic tile cannot be applied with adhesive directly to the subfloor).NBC20 Div.B 9.30.6.1.(2)-
PCF_19491949Addition of Non-asbestos Cement Board as an acceptable protection.This proposed change seeks to include 12 mm non- asbestos cement board as an acceptable material for the protection of insulation.NBC20 Div.B 9.25.2.3.(6)-
PCF_19481948Removal of "unreinforced concrete" and "nominally reinforced concrete" in Part 9This proposed change seeks to provide clarification of Part 9 requirements for concrete by removing the term "nominally reinforced concrete" and replacing "unreinforced concrete" with "concrete".NBC20 Div.B 9.3.1.1.(1),
NBC20 Div.B 9.3.1.1.(2),
NBC20 Div.B 9.3.1.6.(1),
NBC20 Div.B 9.3.1.7.(2)
-
PCF_19471947(CCR 2010) Adding Pointer to Relevant Requirements on Farm BuildingsThis proposed change suggested to revise Sentence 3.3.6.6.(1) of Division B of NBC to raise Code users' awareness on relevant requirements in Sentence 2.2.8.1.(4) on the classification of farm buildings used for the storage of ammonium nitrate. NBC20 Div.B 2.2.8.1.(4),
NBC20 Div.B 3.3.6.6.(1),
NFC20 Div.B 3.2.9.2.(1)
-
PCF_19431943Harmonizing the Standard for Whole Building Air Leakage TestingThis proposed change harmonizes the standard for whole building air leakage testing referenced in the prescriptive and modeling requirements in the NECB by only referring to ASTM E3158, the newer, more accurate and more reproducible testing procedure. NECB20 Div.B 8.4.2.9.(2)NMCC on Climate Change Mitigation: Review — Recommended for Public Review
2025-11-18
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
PCF_19411941Door-Swing Area within a Universal WashroomThis proposed change clarifies that the 1700 mm diameter turning space within a universal washroom does not overlap with the space occupied by an inward swinging door.NBC20 Div.B 3.8.3.13.(1)Use and Egress: Draft
2024-06-10
PCF_19371937Exhaust Ducts Serving Laundry-drying Equipment This change will provide clarification of the requirements for exhaust ducts referenced in Sentence 9.32.1.3.(2) by directly stating in the body of the code the practicality that Note A-9.32.1.3 provides and will ensure consistency between Sentences 6.3.2.10(7) and 9.32.1.3.(2).NBC20 Div.B 9.32.1.3.(2),
NBC20 Div.B 6.3.2.10.(7)
-
PCF_19351935OP Objective and Intent Statement for Farm Buildings in NBCIntroduces OP objectives and intent statements for farm building requirements in the NBC. NBC20 Div.B 2Draft
2023-08-23
Fire Protection: Review
2023-09-14
Hazardous Materials and Activities: Review — Editorial Revision/Errata (No Public Review)
2023-09-22
Hazardous Materials and Activities: Review
2023-10-28
Hazardous Materials and Activities: Review
2024-03-22
Fire Protection: Review
2024-03-27
CBHCC: Review — Withdrawn
2024-04-30
Fire Protection: Review
2024-06-03
PCF_19081908Modernizing the language in washroom provisionsThe proposed change modernizes the language in washroom provisions in the NBC to include gender-based terms instead of sex-based termsNBC20 Div.B 3.7.2.2.Use and Egress: Draft
2024-04-17
Use and Egress: Review — Further Review
2024-06-04
PCF_19071907Width of doorways around non-exit stairsExpanding the application of Sentence 3.4.3.3.(1) to doorways around non-exit stairsNBC20 Div.B 3.3.1.14.(1)-
PCF_19061906Application of Dampproofing MaterialThis code change is to clarify the proper application of dampproofing material to foundation walls as found in Sentence 9.13.2.1.(1).NBC20 Div.B 9.13.2.1.(1)-
PCF_19021902Clarifications for Artcile 4.1.8.3.-NBC20 Div.B 4.1.8.3.-
PCF_18951895Datum for the Determination of N̅60 and s̅u in Article 4.1.8.1.The proposed change revises the datum used for the determination of N̅60 and s̅u in Article 4.1.8.1. to make it consistent with that used in the rest of Subsection 4.1.8.NBC20 Div.B 4.1.8.1.Earthquake Design: Review — Recommended for Public Review
2023-08-30
CBHCC: Pre-Public Review — Proceed
2024-01-25
Earthquake Design: Review of PR Comments — Withdrawn
2024-06-03
PCF_18931893In-factory Airtightness Testing of Factory-constructed BuildingsThis proposed change introduces the in-factory airtightness testing requirement for single-section, single-story, factory-constructed buildings.NBC20 Div.B 9.36.6.3.-
PCF_18911891(split from PCF 1819) Harmonize Airtightness Requirements in NBC Section 9.36.This proposed change (1) aligns the airtightness requirements in the Tiered Performance Path with the Performance Path, and (2) allow the use of 3.0 or 2.5 ACH50 for proposed house modelling without conducting an airtightness test for attached and detached houses, respectively .--
PCF_18871887Passive Stack Radon Mitigation with Active Radon Stack OptionThe addition of passive vertical stack radon mitigation systems, as well as an active side wall mitigation option, to dwelling units and building containing residential occupancies in contact with the ground.NBC20 Div.B 9.13.4.Housing and Small Buildings: Review — Further Review
2022-06-08
PCF_18851885Location of Water-bottle Filling Stations and Drinking Fountains in a Building Required to be Barrier-freeThis proposed change clarifies where a water-bottle filling station and a drinking fountain complying with Subsection 3.8.3. should be provided in a barrier-free building.NBC20 Div.B 3.8.2.8.(10),
NBC20 Div.B 3.8.2.8.(11)
Use and Egress: Draft
2024-05-29
PCF_18771877(on-hold) Adjustment Factor for Unguarded Blower Door Airtightness Testing ResultsThis proposed change introduces an adjustment factor for the airtightness results of unguarded blower door testing of attached units.NBC20 Div.B 9.36.6.3.,
NBC20 Div.B 9.36.6.4.,
NBC20 Div.B 9.36.7.3.,
NBC20 Div.B 9.36.8.8.
Housing and Small Buildings: Review
2023-06-08
PCF_18711871Heat Pump Water Heater ModellingThis updates the modelling rules for the reference house when the proposed house uses a heat pump water heaterNBC20 Div.B 9.36.7.3.-
PCF_18561856Rooftop enclosures as a storyThis proposed change clarifies whether a rooftop enclosure should be counted as a storey of building.NBC20 Div.B 3.2.1.1.,
NBC20 Div.B 3.2.5.8.,
NBC20 Div.B 3.2.6.1.,
NBC20 Div.B 3.5.4.1.
Fire Protection: Draft
2023-02-20
Fire Protection: Review — Withdrawn
2023-03-16
PCF_18551855Maximum Travel of Enclosed Vertical Platform Lifts for PassengersThis proposed change limits the travel of enclosed vertical platform lifts.NBC20 Div.B 3.8.3.7.Use and Egress: Draft
2023-02-17
NMCC on Accessibility: Review — Withdrawn
2025-05-16
PCF_18541854Rooftop Enclosures as a StoreyThis proposed change clarifies whether a rooftop enclosure provided for elevator machinery, a stairway or a service room is intended to be considered as a storey in certain fire safety applications.NBC20 Div.B 3.2.5.8.,
NBC20 Div.B 3.2.6.1.
Fire Protection: Draft
2023-02-14
Fire Protection: Review — Recommended for Public Review
2023-03-16
Use and Egress: Review
2023-06-07
TG/WG Development
2023-07-11
Fire Protection: Review
2024-03-27
CBHCC: Review — Deferred
2024-04-30
Fire Protection: Review
2024-06-03
PCF_18491849Hot Works Site Preparation and Safety ChecksThis proposed change lists the required activities to reduce the potential of accidental ignition of combustible materials from hot works.NFC20 Div.B 5.2.1.,
NFC20 Div.B 5.2.3.
NMCC on Fire and Life Safety: Draft
2025-12-08
PCF_18481848Hot Work Permit SystemThis proposed change sets the parameters to initiate a hot work permit system.NFC20 Div.C 2.2.NMCC on Fire and Life Safety: Draft
2025-12-08
PCF_18371837Prescriptive Trade-off Path - Heat Pump Water HeatersThis proposed change updates the energy conservation points assigned to heat pump water heatersNBC20 Div.B 9.36.8.10.-
PCF_18221822Thermal Bridging Requirements Section 9.36.Update the thermal bridging requirements to reflect new modelling and standardsNBC20 Div.B 9.36.2.Housing and Small Buildings: Review
2023-06-08
Energy Efficiency: Draft
2023-08-23
NMCC on Climate Change Mitigation: Review — Withdrawn
2025-12-17
PCF_18191819Removing ACH50 and Harmonizing Airtightness Requirements in Section 9.36.This proposed change replaces ACH50 with NLR50 as the regulating airtightness metric in Section 9.36. and revises the airtightness requirements in the compliance paths and for proposed house modeling.NBC20 Div.B 9.36.5.10.,
NBC20 Div.B 9.36.5.14.,
NBC20 Div.B 9.36.6.4.,
NBC20 Div.B 9.36.7.3.
Energy Efficiency: Review — Recommended for Public Review
2023-08-21
Housing and Small Buildings: Review
2023-10-10
CBHCC: Pre-Public Review — Proceed
2024-01-25
Energy Efficiency: Review of PR Comments — Defer
2024-06-06
NMCC on Climate Change Mitigation: Review — Withdrawn
2025-12-17
PCF_18171817Direction of Door Swing with Low Occupant LoadThis proposed change permits an exit door serving an area with a low occupant load to swing inward.NBC20 Div.B 3.4.6.12.Use and Egress: Draft
2024-05-27
PCF_18161816Small Quantity Exemptions for Dangerous GoodsThis proposed change simplifies the requirements for the small quantity exemptions of dangerous goods.NFC20 Div.B 3.2.7.1.NMCC on Fire and Life Safety: TG/WG Development
2025-08-13
PCF_18141814Removing the NLA Airtightness MetricThis proposed change removes the normalized leakage area (NLA) metric for airtightness level determination.NBC20 Div.B 9.36.6.2.,
NBC20 Div.B 9.36.6.3.,
NBC20 Div.B 9.36.6.4.
Draft
2022-11-04
Energy Efficiency: Review
2023-03-01
Housing and Small Buildings: Review
2023-06-08
CBHCC: Review — Recommended for Public Review
2023-08-17
Energy Efficiency: Review of PR Comments — Withdrawn
2024-06-06
PCF_18071807Introduction of Requirements for Screens and Curtains Used in Farm BuildingsThis proposed change introduces flame-testing requirements for screens and curtains used in farm buildings, and includes options to divide screens and curtains into smaller, non-contiguous areas.NFC20 Div.B 2.3.2.Hazardous Materials and Activities: TG/WG Development
2022-10-12
Hazardous Materials and Activities: Review
2023-08-15
Hazardous Materials and Activities: TG/WG Development
2023-08-23
Hazardous Materials and Activities: Review
2023-09-06
Fire Protection: Review — Recommended for Public Review
2023-09-14
CBHCC: Pre-Public Review — Proceed
2024-01-25
Hazardous Materials and Activities: Review of PR Comments
2024-05-22
Fire Protection: Review of PR Comments — Withdrawn
2024-06-03
PCF_18061806Fabrics, Films and Membranes Used in Farm Building Envelope ConstructionThis proposed change introduces flame-spread rating requirements for fabrics, films and membranes when used in building envelope construction and provides an exemption for Group G, Division 4 major occupancy.NBC20 Div.B 2.2.1.14.Hazardous Materials and Activities: TG/WG Development
2022-09-12
Hazardous Materials and Activities: Review
2023-08-15
Fire Protection: Review — Deferred
2023-11-20
Fire Protection: Review
2024-03-01
Fire Protection: Review — Deferred
2024-06-03
PCF_18041804Updates to Referenced Documents-NBC20 Div.B 1.3.1.2.,
NFC20 Div.B 1.3.1.2.,
NPC20 Div.B 1.3.1.2.,
NECB20 Div.B 1.3.1.2.
Earthquake Design: Review
2022-09-09
Housing and Small Buildings: Review
2022-09-13
Use and Egress: Review
2022-09-28
HVAC and Plumbing: Review
2022-09-28
Hazardous Materials and Activities: Review
2022-09-29
Structural Design: Review
2022-09-29
Fire Protection: Review
2022-10-04
Energy Efficiency: Review
2022-10-13
Environmental Separation: Review
2022-10-13
EC: Review — Recommended for Public Review
2022-10-13
HVAC and Plumbing: Review of PR Comments
2023-02-24
Fire Protection: Review of PR Comments
2023-03-02
Use and Egress: Review of PR Comments
2023-03-15
Energy Efficiency: Review of PR Comments
2023-04-04
Structural Design: Review of PR Comments
2023-04-04
Environmental Separation: Review of PR Comments
2023-04-05
Hazardous Materials and Activities: Review of PR Comments
2023-05-02
Housing and Small Buildings: Review of PR Comments
2023-05-31
Earthquake Design: Review of PR Comments
2023-06-08
SC Div AC: Review of PR Comments — Proceed with editorial revisions
2023-08-09
CBHCC: CCBFC Decision — Approved for publication
2024-04-30
PCF_17871787Combustible Projections to Property LineThis proposed change revises Sentence 3.2.3.6.(5) to reference "property line". NBC20 Div.B 3.2.3.6.(5)Fire Protection: Review — Further Review
2022-05-05
Fire Protection: Review — Editorial Revision/Errata (No Public Review)
2022-09-22
PCF_17831783Identification of Sanitary Drainage SystemThis CCR aims to add color requirements for the identification of the sanitary drainage system to Article 2.2.1.3. IdentificationNPC20 Div.B 2.2.1.3.-
PCF_17811781Fire Test Method for Firestops at Perimeter JointsThis proposed change replaces the referenced standard for fire test method, ASTM E2307, "Standard Test Method for Determining Fire Resistance of Perimeter Fire Barriers Using Intermediate-Scale, Multi-story Test Apparatus," with the CAN/ULC-S115:2023, "Standard Method of Fire Tests of Firestop Systems."NBC20 Div.B 3.1.8.3.(2),
NBC20 Div.B 3.1.8.3.(4),
NBC20 Div.B 9.10.9.2.(4)
Fire Protection: Draft
2024-05-06
Fire Protection: Review — Recommended for Public Review
2024-06-03
Housing and Small Buildings: Review
2024-06-19
Housing and Small Buildings: Review — Recommended for Public Review
2024-08-14
Fire Protection: Review
2024-09-03
NMCC on Fire and Life Safety: Review — Recommended for Public Review
2025-09-15
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
PCF_17801780Benches in Universal Dressing and Shower RoomsThis proposed change requires minimum loading and maintenance quality requirements for benches in universal dressing and shower rooms.NBC20 Div.B 3.8.3.17.Use and Egress: Draft
2022-08-11
Use and Egress: Review — Further Review
2024-06-04
PCF_17791779Location of Toilet Paper Dispenser within an Accessible Water-Closet StallThis proposed change sets the location of a toilet paper dispenser within an accessible water-closet stall.NBC20 Div.B 3.8.3.12.(1)Use and Egress: Draft
2024-06-21
PCF_17781778Replace the Term "Hearing Impairment" with "People with Low or No Hearing"This proposed change replaces the term "hearing impaired" with "people with low or no hearing" in Part 3. NBC20 Div.B 3.2.4.19.,
NBC20 Div.B 3.8.
Use and Egress: Draft
2022-08-10
Use and Egress: Review — Further Review
2024-06-04
Draft
2025-02-27
NMCC on Accessibility: Review — Recommended for Public Review
2025-05-16
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
PCF_17701770Audible and visible signal devicesThis PCF updates requirements for silencing and function of visible alarmsNBC20 Div.B 3.2.4.Use and Egress: TG/WG Development
2021-11-19
PCF_17691769Lighting within an Occupied WashroomThis proposed change introduces a minimal reasonable timeframe of illumination in an occupied washroom.NBC20 Div.B 9.34.2.7.Use and Egress: Draft
2021-12-21
Use and Egress: Review
2022-05-25
Housing and Small Buildings: Review
2022-06-08
Energy Efficiency: Review
2022-07-20
Use and Egress: Review
2022-11-09
Use and Egress: Review
2023-09-26
Housing and Small Buildings: Review — Recommended for Public Review
2024-02-08
Energy Efficiency: Review
2024-04-04
Housing and Small Buildings: Review — Deferred
2024-04-12
Use and Egress: Review
2024-06-05
PCF_17651765Projection of Protruding Building ElementsThis proposed change extends the Part 9 requirements on the projection of protruding building elements to most paths of travel. NBC20 Div.B 9.5.,
NBC20 Div.B 9.9.5.3.,
NBC20 Div.B 3.3.1.8.(2),
NBC20 Div.B 3.3.1.8.(3)
Use and Egress: Draft
2022-01-04
Use and Egress: TG/WG Development
2022-08-11
Use and Egress: Review
2022-09-28
Housing and Small Buildings: Review
2022-10-06
TG/WG Development
2022-12-12
Housing and Small Buildings: Review — Further Review
2023-01-18
TG/WG Development
2023-02-06
Use and Egress: Review
2023-05-02
Housing and Small Buildings: Review — Recommended for Public Review
2023-05-31
CBHCC: Review — Recommended for Public Review
2023-08-17
Housing and Small Buildings: Review of PR Comments
2024-01-30
Use and Egress: Review of PR Comments
2024-03-08
Housing and Small Buildings: Review of PR Comments — Defer
2024-06-19
PCF_17641764Tactile Attention Indicator SurfacesThis proposed change introduces requirements on the provision of tactile attention indicator surfaces at certain changes in elevation.NBC20 Div.B 3.3.1.19.,
NBC20 Div.B 9.8.6.
Use and Egress: Draft
2022-03-01
Use and Egress: TG/WG Development
2022-08-11
Use and Egress: Review
2022-09-28
Use and Egress: TG/WG Development
2022-12-12
PCF_17511751Requirements for Non-fixed Seating in Assembly OccupanciesThis proposed change updates the NFC requirements for non-fixed seating in assembly occupancies and introduces an explanatory Note regarding standing-only spaces in assembly occupancies.NFC20 Div.B 2.7.1.5.Use and Egress: Draft
2022-01-03
Use and Egress: TG/WG Development
2022-03-24
Use and Egress: TG/WG Development
2022-04-14
Use and Egress: Review — Recommended for Public Review
2022-05-25
Use and Egress: Analysis of PR Comments — Recommend to withdraw
2023-01-24
Use and Egress: Review of PR Comments — Withdrawn
2023-03-15
PCF_17301730Tests and Inspection of Drainage or Venting SystemsVisual inspection of the pipe systemNPC20 Div.B 2.3.6.1.HVAC and Plumbing: TG/WG Development
2022-05-26
HVAC and Plumbing: Review — Withdrawn
2022-07-29
PCF_17151715Washroom TerminologyCoordinate the identification and replacement of multiple terms that have been used interchangeably in the NBC with the term "washroom"NBC20 Div.B 9.32.3.7.(4),
NBC20 Div.B 9.32.3.7.(7),
NBC20 Div.B 9.32.3.11.(1),
NBC20 Div.B 9.5.4.1.(1),
NBC20 Div.B 9.9.5.9.(1),
NBC20 Div.B 9.10.12.4.(5),
NBC20 Div.B 9.10.14.4.(7),
NBC20 Div.B 9.10.17.11.(1),
NBC20 Div.B 9.23.15.2.(4),
NBC20 Div.B 9.32.3.3.(10),
NBC20 Div.B 9.33.6.10.(2),
NBC20 Div.B 9.33.6.11.(2),
NBC20 Div.B 9.34.2.2.(1)
Housing and Small Buildings: Review
2022-12-08
HVAC and Plumbing: Review
2023-09-13
Housing and Small Buildings: Review — Withdrawn
2024-02-08
Housing and Small Buildings: Review — Withdrawn
2024-06-20
PCF_17101710Washrooms/bathroom and other interchangeable termsCoordinate the identification and replacement of multiple terms that have been used interchangeably in the NBC with the term "washroom"NBC20 Div.B 3.1.13.3.,
NBC20 Div.B 3.2.2.21.(1),
NBC20 Div.B 3.3.3.5.,
NBC20 Div.B 3.4.4.4.(8),
NBC20 Div.B 3.8.3.6.(3),
NBC20 Div.B 3.2.6.2.(5),
NBC20 Div.B 3.2.4.20.(9),
NBC20 Div.B 3.2.2.35.(4)
-
PCF_17081708Maximum length of barrier-free rampsProvide guidance for overall length of barrier-free ramps recognizing that travel in either direction on a barrier-free ramp requires increased strength and stamina by all users.NBC20 Div.B 3.8.3.5.Use and Egress: TG/WG Development
2021-12-10
NMCC on Accessibility: TG/WG Development
2025-09-16
NMCC on Accessibility: TG/WG Development
2025-11-20
PCF_17051705L-shaped grab bar for water-closet stalls for persons with limited mobilityThis PCF requires an L-shaped grab bar instead of a horizontal grab bar at water-closets for stalls for people with limited mobility. NBC20 Div.B 3.8.3.15.,
NBC20 Div.B 3.8.3.12.
Use and Egress: TG/WG Development
2021-12-10
NMCC on Accessibility: TG/WG Development
2025-07-04
NMCC on Accessibility: TG/WG Development
2025-09-16
PCF_17011701Spatial separation table valuesThis proposed change adds the equation upon which the values in spatial separation tables in Part 9 were based to the Notes to Part 9.NBC20 Div.B 9.10.14.4.,
NBC20 Div.B 9.10.15.4.
TG/WG Development
2021-04-15
Fire Protection: Review
2021-10-27
PCF_17001700Activation of smoke dampers by smoke detectorThis proposed change clarifies that the activation of smoke damper and combination smoke/fire damper does not necessarily require a fire alarm system where it is not required. NBC20 Div.B 3.2.4.10.(1)Use and Egress: Draft
2021-10-06
Fire Protection: Review — Withdrawn
2021-10-26
PCF_16971697Cross reference to firestopping provisions for permitted service penetrationsThis proposed change adds a cross reference to firestopping provisions for permitted service penetrations where Article 9.10.18.6. allows each portion of a building on either side of a 1 hour fire rated separation to be treated as a separate building.NBC20 Div.B 9.10.18.6.(1)Fire Protection: Draft
2021-10-06
Fire Protection: Review
2021-10-26
PCF_16961696Drains Serving Elevator Pits-NPC20 Div.B 2.4.3.6.HVAC and Plumbing: Draft
2021-09-27
PCF_16951695Wet Vents-NPC20 Div.B 2.5.6.2.-
PCF_16941694Air gaps permitted in a noxious environmentThis proposed change allows air gaps to be located in a noxious environment when a zone protection is provided outside that noxious environment.NPC20 Div.B 2.6.2.9.HVAC and Plumbing: Draft
2021-09-27
HVAC and Plumbing: TG/WG Development
2022-02-18
HVAC and Plumbing: Review — Withdrawn
2022-10-25
PCF_16851685Reference CAN/ULC-S134 for protection of foamed plastic This proposed change modifies the test requirements for protection of foamed plastic in exterior walls.NBC20 Div.B 3.2.3.8.TG/WG Development
2021-04-12
Fire Protection: Review
2021-05-06
PCF_16841684Revision of Intent Statements and Attributions for NBC Sentences 3.2.3.7.(3) and (4)This proposed change deletes the attributions and revises the intent statements for Sentences 3.2.3.7.(3) and (4) of Division B of the NBC. NBC20 Div.B 3.2.3.7.(3),
NBC20 Div.B 3.2.3.7.(4)
Fire Protection: TG/WG Development
2021-05-07
Fire Protection: Review — Recommended for Public Review
2021-05-13
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
PCF_16811681Distillery as a medium-hazard industrial occupancyThis proposed change adds distilleries as an example of medium-hazard industrial occupancy in the NBC and NFC. NBC20 Div.B 3.1.2.1.(1),
NFC20 Div.B 4.10.2.1.
TG/WG Development
2021-04-17
Fire Protection: Review — Further Review
2021-05-13
Hazardous Materials and Activities: Review — Further Review
2021-09-29
PCF_16661666Barrier-free path of travel connecting barrier-free facilitiesThis proposed change requires that where clear floor spaces are required for barrier-free facilities, that they be connected to the barrier-free path of travel. NBC20 Div.B 3.8.3.2.NMCC on Accessibility: TG/WG Development
2025-06-23
NMCC on Accessibility: TG/WG Development
2025-09-16
NMCC on Accessibility: TG/WG Development
2025-11-20
NMCC on Accessibility: Review — Recommended for Public Review
2026-01-09
PCF_16441644Replace the Term "Visually Impaired Persons" with "People with Low or No Vision"This proposed change replaces the terms "visually impaired persons" and "people with vision loss" with "people with low or no vision" in Parts 3 and 9.NBC20 Div.B 3.3.1.8.(2),
NBC20 Div.B 3.8.,
NBC20 Div.B 9.8.7.3.(1),
NBC20 Div.B 9.8.7.3.(2),
NBC20 Div.B 9.9.5.3.(1)
Use and Egress: Draft
2020-02-04
Use and Egress: Review
2024-06-04
Draft
2025-02-27
NMCC on Accessibility: Review — Recommended for Public Review
2025-05-16
Standing Codes Coordination Committee: Review
2025-11-21
CBHCC: Pre-Public Review — Proceed
2026-01-22
PCF_16381638Protection of electrical conductors within a storeyClarification of wording on the exemption of electrical conductor protection for fire alarm system branch circuits connecting individual devices and transponders in a single storeyNBC20 Div.B 3.2.7.10.(7)Use and Egress: Draft
2019-10-01
Use and Egress: Review
2022-05-25
Housing and Small Buildings: Review
2022-06-08
Use and Egress: Review — Editorial Revision/Errata (No Public Review)
2022-06-20
PCF_15891589Vision glass in doors in primary horizontal routesThis change proposes to require that doors in primary horizontal routes be provided with a vision panel.NBC20 Div.B 3.3.1.20.Use and Egress: TG/WG Development
2019-05-07
Use and Egress: TG/WG Development
2019-06-12
Use and Egress: Review — Further Review
2019-06-18
Use and Egress: TG/WG Development
2022-05-11
PCF_15851585Handrail Colour Contrast This proposed change adds a requirement of colour contrast for handrails compared to the adjacent background and wall surfaces. NBC20 Div.B 3.4.6.5.Use and Egress: Draft
2019-04-29
Use and Egress: TG/WG Development
2019-05-07
Use and Egress: TG/WG Development
2022-11-07
PCF_15831583Accessible Parking This proposed change introduces requirements for accessible parking areas in the NBC. NBC20 Div.B 3.8.2.5.,
NBC20 Div.B 3.8.3.
Use and Egress: TG/WG Development
2019-04-29
Use and Egress: Review — Further Review
2019-05-29
Use and Egress: TG/WG Development
2019-06-12
Use and Egress: Review — Further Review
2019-06-18
Use and Egress: TG/WG Development
2022-03-11
PCF_15821582Grab Bars in Bathtubs and ShowersThis proposed change introduces a requirement for the installation of grab bars in all bathtubs and showers.NBC20 Div.B 9.31.1.,
NBC20 Div.B 9.31.2.
Housing and Small Buildings: Review
2019-05-22
Housing and Small Buildings: Review — Recommended for Public Review
2019-06-25
TG/WG Development
2020-09-03
Housing and Small Buildings: Review of PR Comments
2021-02-25
Use and Egress: Review of PR Comments
2021-03-14
Use and Egress: Review of PR Comments
2021-03-29
Use and Egress: Review of PR Comments
2021-04-23
Use and Egress: Review of PR Comments
2021-05-05
Housing and Small Buildings: Review of PR Comments — Defer
2021-05-11
PCF_15811581Grab Bars for Bathtubs and ShowersThis proposed change introduces requirements on the installation of grab bars for bathtubs and showers.NBC20 Div.B 3.7.2.Housing and Small Buildings: Review
2019-05-22
Use and Egress: Review — Recommended for Public Review
2019-05-29
Housing and Small Buildings: Review
2019-06-25
Use and Egress: Review
2019-06-25
Use and Egress: Review
2019-07-16
Housing and Small Buildings: Review of PR Comments
2020-05-29
Housing and Small Buildings: Review of PR Comments
2020-06-12
TG/WG Development
2020-09-03
Housing and Small Buildings: Analysis of PR Comments
2021-02-25
Housing and Small Buildings: Analysis of PR Comments
2021-03-10
Use and Egress: Review of PR Comments
2021-03-15
Use and Egress: Review of PR Comments
2021-03-29
Use and Egress: Review of PR Comments
2021-04-23
Use and Egress: Review of PR Comments — Defer
2021-05-05
PCF_15781578Step dimensions in dwelling unitsThis proposed change harmonizes step dimensions in dwelling units (rise and run) with step dimensions in public buildings NBC20 Div.B 9.8.4.-
PCF_15751575Change Defined Term "Barrier-free" to "Accessible"The proposed changes replace the term "barrier-free" by "accessible" in the NBC.NBC20 Div.A 1.4.1.2.,
NBC20 Div.A 2.2.1.1.(1),
NBC20 Div.A 2.1.1.2.(5)
Use and Egress: TG/WG Development
2019-04-24
Use and Egress: Review
2019-05-30
EC: Review — Editorial Revision/Errata (No Public Review)
2019-07-11
EC: Review — Further Review
2019-12-13
EC: TG/WG Development
2021-07-21
Draft
2025-02-27
PCF_15721572Tactile attention indicator surfaces (TAIS) for exit StairsThe change proposed location where TAIS shall be installed in exit stairs.NBC20 Div.B 3.3.1.19.Use and Egress: TG/WG Development
2019-05-07
Use and Egress: TG/WG Development
2019-06-12
Use and Egress: Review — Further Review
2019-06-18
Use and Egress: TG/WG Development
2022-11-07
PCF_15071507Minimum Cleanout Fitting Dimension This proposed change sets the minimum dimension for cleanout fittings to be at least 4 in. in size for building drains that are at least 4 in. in size.NPC20 Div.B 2.4.7.HVAC and Plumbing: Draft
2019-02-28
PCF_14701470Backwater valve and sump pit drainageAddition of backwater valves to Article 9.14.5.2. and clarification of discharge location of sump pits.NBC20 Div.B 9.14.5.,
NECB20 Div.B 8.4.5.1.
Housing and Small Buildings: Review — Deferred
2019-05-23
HVAC and Plumbing: Review
2023-03-13
PCF_14641464Coatings of connectors and fasteners in contact with treated woodThe proposed change would revise Subsection 9.23.6. to increase the galvanized coating criteria for fasteners and connectors in contact with pressure-treated wood.NBC20 Div.B 9.23.2.-
PCF_14401440Limiting Distance and Fire Department ResponseThis proposed change clarifies that the locations exempted from having to be sprinklered according to the standards referenced in Article 3.2.5.12. are not actually exempted in the context of the application of Article 9.10.15.3. when they are located adjacent to the exposing building face. NBC20 Div.B 9.10.15.3.Housing and Small Buildings: Review — Recommended for Public Review
2019-05-24
Housing and Small Buildings: Review of PR Comments — Defer
2020-12-16
PCF_14321432Required Handrails for Stairs Serving a Single Dwelling Unit or a House with a Secondary SuiteThis proposed change harmonizes the number of handrails required for interior and exterior stairs and ramps serving a single dwelling unit or a house with a secondary suite.NBC20 Div.B 9.8.7.1.Housing and Small Buildings: Review — Recommended for Public Review
2019-05-23
Use and Egress: Review of PR Comments
2020-06-25
Housing and Small Buildings: Review of PR Comments — Defer
2020-08-12
PCF_14291429Graspability of HandrailsChange to Part 9 handrail graspability design to align with Part 3 definition of graspable.NBC20 Div.B 9.8.7.5.-
PCF_13931393Defined Term Storm WaterThe proposed change would harmonize between the English and the French definition of the term storm water.NPC20 Div.A 1.4.1.2.-
PCF_13891389Location of Drain PipesThis proposed change requires that a drain pipe that is directly connected to multiple fixture outlet pipes or a fixture drain be located within a single room or suite. NPC20 Div.B 2.4.2.3.HVAC and Plumbing: Draft
2019-02-28
HVAC and Plumbing: Review — Recommended for Public Review
2019-04-17
HVAC and Plumbing: Review of PR Comments — Defer
2020-05-12
TG/WG Development
2022-02-15
TG/WG Development
2022-03-21
HVAC and Plumbing: Review — Withdrawn
2022-09-28
PCF_13811381Drainage to Sumps by GravityThe proposed change would prohibit the use of a sump or tank on piping that can drained by gravity.NPC20 Div.B 2.4.6.3.HVAC and Plumbing: TG/WG Development
2018-09-12
PCF_13671367Capability of SupportThe proposed change would add clarification to the Sentence 2.3.4.1.(2)-HVAC and Plumbing: Draft
2018-07-16
PCF_13531353Location of Low Permeance MaterialsThis proposed change clarifies the application of Table 9.25.5.2.NBC20 Div.B 9.25.5.2.Housing and Small Buildings: Review — Recommended for Public Review
2019-05-23
Housing and Small Buildings: Review of PR Comments
2020-05-08
Housing and Small Buildings: Review of PR Comments — Defer
2020-07-20
PCF_12991299Long-life Sealed Battery Smoke AlarmsThis proposal permits long-life sealed battery smoke alarms in location where the codes allow the used of battery-operated smoke alarms.NFC20 Div.B 2.1.3.3.,
NBC20 Div.B 9.10.19.4.
Draft
2022-05-02
Use and Egress: Review
2024-04-05
PCF_12371237Handrails: A-9.8.7.5. Ergonomic Design. Notion of "graspability of the handrails"This proposed change clarifies the notion of "graspability of the handrails"NBC20 Div.B 9.8.7.5.-
PCF_12331233Handrails: Dimensional limits for handrail cross-sections for Part 9 BuildingsThis proposed change would revise Article 9.8.7.5. Ergonomic Design to introduce the dimensional limits for handrail cross-sections for Part 9 buildingsNBC20 Div.B 9.8.7.5.-
PCF_11411141Application of 9.10.15. to garages and carportsThis Proposed change clarifies how to apply spatial separations requirements to attached garages and attached carports to dwelling unitsNBC20 Div.B 9.10.15.1.Housing and Small Buildings: Review — Deferred
2018-07-09
Housing and Small Buildings: Review — Deferred
2019-05-24
PCF_10771077Inspection, Testing and MaintenanceThis proposed change clarifies that municipal hydrants are required to comply with the requirements for inspection, testing, and maintenance in accordance with Sentence 6.4.1.1.(1) of Division B of the NFC. NFC20 Div.B 6.4.1.1.Hazardous Materials and Activities: Review — Recommended for Public Review
2017-05-16
Pre-Public Review — Proceed
2017-10-26
Hazardous Materials and Activities: Review of PR Comments — Defer
2018-05-28
PCF_855855Spatial Separation Requirements and Fire Department Response Time- Option 3This proposed change eliminates the 10 Min response time, states that the requirements in Subsection 9.10.15. are the default based on the assumption that the AHJ have evaluated the firefighting capabilities and explains in an Appendix Note the fallback position.NBC20 Div.B 9.10.15.-
PCF_854854Spatial Separation requirements and Fire Department Response Time - Option 2This proposed change eliminates the 10 Min response time, allows the AHJ to establish its own limiting distance or apply the traditional limiting distance restrictions and explains in an Appendix Note the fire department assumptions based on which the code requirements were developed.NBC20 Div.B 9.10.15.-
PCF_853853Spatial Separation Requirements and Fire Department Response Time- Option 1This proposed change eliminates the 10 Min response time without replacement and explains in an Appendix Note (Linked to the Subsection title) the fire department assumptions based on which the code requirements were developed.NBC20 Div.B 9.10.15.-
PCF_851851Travel limit to exitThis propose changes provides relaxations to travel limit to exit in a sprinklered buildingsNBC20 Div.B 9.9.9.1.-
PCF_805805Replace CSA A82.31 with ASTM C840 on Gypsum Board InstallationThis proposed change replaces the reference to an outdated CSA standard with an up-to-date acceptable ASTM standard on gypsum board installation and makes Part 5, Part 9 and Appendix D consistent.NBC20 Div.B 9.29.5.1.(2),
NBC20 Div.B 9.10.9.2.(5),
NBC20 Div.B 9.10.12.4.(3),
NBC20 Div.B 9.10.14.5.(8),
NBC20 Div.B 9.10.14.5.(12),
NBC20 Div.B 9.10.15.5.(7),
NBC20 Div.B 9.10.15.5.(11)
Housing and Small Buildings: TG/WG Development
2013-10-21
Housing and Small Buildings: Review — Deferred
2013-11-20
Fire Protection: Review
2014-04-29
PCF_741741Information Required on Structural DrawingsThis proposed change deletes the reference to cladding in Sentence (1) and adds a new Sentence dealing with structural drawings of secondary structural elements. NBC20 Div.C 2.2.4.3.Structural Design: Review
2013-04-05
Structural Design: Review
2019-03-18
Environmental Separation: Review
2019-04-12
EC: Review — Further Review
2019-07-11
Structural Design: Review
2019-07-24
EC: Review — Recommended for Public Review
2019-08-06
Structural Design: Analysis of PR Comments
2020-04-20
Environmental Separation: Review of PR Comments
2020-04-30
Use and Egress: Review of PR Comments
2020-05-11
Energy Efficiency: Review of PR Comments
2020-05-11
Hazardous Materials and Activities: Review of PR Comments
2020-05-12
Fire Protection: Review of PR Comments
2020-05-14
HVAC and Plumbing: Review of PR Comments
2020-06-11
Earthquake Design: Review of PR Comments
2020-06-15
Housing and Small Buildings: Review of PR Comments
2020-06-26
Structural Design: Review of PR Comments
2020-07-20
EC: Review of PR Comments
2021-03-10
Structural Design: Review of PR Comments
2021-05-20
EC: Review — Further Review
2021-05-21
PCF_514514Steel studs sizes for non-loadbearing interior wallsThis proposed change is considered an errata as it aims to correct an oversight there was a change in referencing a standard for steel wall framing, between the 2005 and the 2010 NBC. The stud sizes in the appendix note A-9.10.3.1 do not match the intended values.NBC20 Div.B 9.10.3.1.Housing and Small Buildings: Review
2013-04-23
PCF_456456Harmonization of Application of National Model CodesThis proposed change harmonizes the application statements of the National Fire Code and the National Building Code by adding the defined term "alteration" to the National Fire Code and rewording the application statement of the NFC to include the new defined term. NFC20 Div.A 1.1.,
NFC20 Div.A 1.4.1.2.
Hazardous Materials and Activities: Draft
2013-04-17
Hazardous Materials and Activities: Draft
2014-04-07
Review — Deferred
2020-03-27
PCF_350350Slip Resistance on Stairs and RampsProposed change to address Part 3-Part 9 differences for public stairs.NBC20 Div.B 3.4.6.1.(1)Use and Egress: Review — Deferred
2012-12-05
Use and Egress: Review — Deferred
2015-02-19
PCF_311311Door Closers for Use with Swinging DoorsThis proposed change introduces the reference to the ULC-S133, "Tests for Door Closers Intended for Use with Swinging Doors" for self-closing devices on foors in fire separations.NBC20 Div.B 3.1.8.13.,
NBC20 Div.B 9.10.13.10.
Fire Protection: Draft
2013-04-23
PCF_164164Combustible DustThis CCR clarifies the design of systems and structures where combustible dust is produced in quantities or concentrations that create an explosion or fire hazard exist. The proposal replaces Articles 5.3.1.4. through 5.3.1.10. with references to applicable NFPA Standards.NFC20 Div.B 5.3.1.Hazardous Materials and Activities: Review — Deferred
2012-06-13
Hazardous Materials and Activities: Review — Deferred
2016-10-18