Please note that corresponding French editions of some updated documents had not yet been published at the time this table was compiled.
Issuing Agency | Document Number | Title of Document | Code Reference |
---|---|---|---|
AAMA | 501-05 | Methods of Test for Exterior Walls | NBC A-5.9.3. CNB A-5.9.3. |
AAMA | 501.1-05 | Standard Test Method for Water Penetration of Windows, Curtain Walls and Doors Using Dynamic Pressure | NBC A-5.9.3. CNB A-5.9.3. |
AAMA | 501.2-09 | Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems | NBC A-5.9.3. CNB A-5.9.3. |
AAMA | 501.4-09 | Recommended Static Test Method for Evaluating Curtain Wall and Storefront Systems Subjected to Seismic and Wind-Induced Inter-Story Drifts | NBC A-5.9.3. CNB A-5.9.3. |
AAMA | 501.5-07 | Test Method for Thermal Cycling of Exterior Walls | NBC A-5.9.3. NBC A-5.9.3.3.(1) CNB A-5.9.3. CNB A-5.9.3.3. 1) NECB 3.2.4.3.(3) CNÉB 3.2.4.3. 3) |
AAMA | 501.6-09 | Recommended Dynamic Test Method for Determining the Seismic Drift Causing Glass Fallout from a Wall System | NBC A-4.1.8.18.(14) and (15) NBC A-5.9.3. CNB A-4.1.8.18. 14) et 15) CNB A-5.9.3. |
ACGIH | 28th Edition | Industrial Ventilation: A Manual of Recommended Practice for Design | NBC 2.4.2.5.(1) NBC 6.2.1.1.(1) NBC 6.3.2.14.(2) NBC A-6.3.1.5. CNB 2.4.2.5. 1) CNB 6.2.1.1. 1) CNB 6.3.2.14. 2) CNB A-6.3.1.5. NFC A-3.2.7.3.(1)(b) CNPI A-3.2.7.3. 1)b) |
ACI | 355.2-19 | Qualification of Post-Installed Mechanical Anchors in Concrete (ACI 355.2-19) and Commentary | NBC 4.1.8.18.(7) CNB 4.1.8.18. 7) |
ACI | 355.4M-19 | Qualification of Post-Installed Adhesive Anchors in Concrete (ACI 355.4M-19) and Commentary | NBC 4.1.8.18.(7) CNB 4.1.8.18. 7) |
AHRI | AHRI 310/380-2014/CSA C744-14 | Packaged Terminal Air-Conditioners and Heat Pumps | NECB Table 5.2.12.1.G |
AHRI | AHRI 310/380-2014/CSA C744-14 | Conditionneurs d'air et thermopompes monoblocs | CNÉB Tableau 5.2.12.1.-G |
AHRI | ANSI/AHRI 1500 (2015) | Performance Rating of Commercial Space Heating Boilers | NBC Table 9.36.3.10. CNB Tableau 9.36.3.10. |
AHRI | ANSI/AHRI 210/240-2008 | Performance Rating of Unitary Air-Conditioning and Air-Source Heat Pump Equipment | NBC Table 9.36.3.10. CNB Tableau 9.36.3.10. NECB Table 5.2.12.1.C CNÉB Tableau 5.2.12.1.-C |
AHRI | ANSI/AHRI 340/360-2007 | Performance Rating of Commercial and Industrial Unitary Air-Conditioning and Heat Pump Equipment | NECB Table 5.2.12.1.A NECB Table 5.2.12.1.C CNÉB Tableau 5.2.12.1.-A CNÉB Tableau 5.2.12.1.-C |
AHRI | ANSI/AHRI 366 (SI/2009) | Performance Rating of Commercial and Industrial Unitary Air-Conditioning Condensing Units | NECB Table 5.2.12.1.D CNÉB Tableau 5.2.12.1.-D |
AHRI | ANSI/AHRI 460-2005 | Performance Rating of Remote Mechanical-Draft Air-Cooled Refrigerant Condensers | NECB Table 5.2.12.2. CNÉB Tableau 5.2.12.2. |
AHRI | ANSI/AHRI 551/591 (SI/2018) | Performance Rating of Water-chilling and Heat Pump Water-heating Packages Using the Vapor Compression Cycle | NECB Table 5.2.12.1.L NECB Table 5.2.12.1.M CNÉB Tableau 5.2.12.1.-L CNÉB Tableau 5.2.12.1.-M |
AHRI | ANSI/AHRI 921 (SI/2015) | Performance Rating of DX-Dedicated Outdoor Air System Units | NECB Table 5.2.12.1.J CNÉB Tableau 5.2.12.1.-J |
AHRI | CAN/ANSI/AHRI 1330-2015 | Performance Rating for Radiant Output of Gas Fired Infrared Heaters | NECB Table 5.2.12.1.P |
AHRI | CAN/ANSI/AHRI 1330-2015 | Détermination des Caractéristiques de Performance Relatives à la Puissance Rayonnée des Appareils de Chauffage à Infrarouges au Gaz | CNÉB Tableau 5.2.12.1.-P |
AHRI | 1060 (I-P/2013) | Performance Rating of Air-to-Air Exchangers for Energy Recovery Ventilation Equipment | NBC 9.36.3.8.(4) CNB 9.36.3.8. 4) |
AHRI | 1061 (SI/2013) | Performance Rating of Air-to-Air Exchangers for Energy Recovery Ventilation Equipment | NECB 5.2.10.1.(5) NECB A-5.2.10.1.(4) CNÉB 5.2.10.1. 5) CNÉB A-5.2.10.1. 4) |
AHRI | 1160 (I-P/2014) | Performance Rating of Heat Pump Pool Heaters (with Addendum 1) | NECB Table 6.2.2.1. CNÉB Tableau 6.2.2.1. |
AHRI | 1230-2014 | Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split Air-Conditioning and Heat Pump Equipment (with Addendum 1) | NECB Table 5.2.12.1.I CNÉB Tableau 5.2.12.1.-I |
AHRI | 1361 (SI/2017) | Performance Rating of Computer and Data Processing Room Air Conditioners | NECB Table 5.2.12.1.H CNÉB Tableau 5.2.12.1.-H |
AISI | North American Standard for Cold-Formed Steel Nonstructural Framing |
NBC 9.24.1.2.(1) CNB 9.24.1.2. 1) |
|
AMCA | ANSI/AMCA 500-D-12 | Methods of Testing Dampers for Rating | NECB 5.2.4.2.(2) CNÉB 5.2.4.2. 2) |
AMCA | ANSI/AMCA 500-L-12 | Methods of Testing Louvers for Rating | NECB 5.2.4.2.(2) CNÉB 5.2.4.2. 2) |
ANSI | A135.6-2012 | Engineered Wood Siding | NBC 9.27.9.1.(1) NBC Table 5.9.1.1. CNB 9.27.9.1. 1) CNB Tableau 5.9.1.1. |
ANSI | A208.1-2009 | Particleboard | NBC 9.23.15.2.(3) NBC 9.29.9.1.(1) NBC 9.30.2.2.(1) NBC D-3.1.1. CNB 9.23.15.2. 3) CNB 9.29.9.1. 1) CNB 9.30.2.2. 1) CNB D-3.1.1. |
ANSI/CSA | ANSI Z21.10.3-2017/CSA 4.3-2017 | Gas-fired water heaters, volume III, storage water heaters with input ratings above 75,000 Btu per hour, circulating and instantaneous | NBC Table 9.36.4.2. CNB Tableau 9.36.4.2. NECB Table 6.2.2.1. CNÉB Tableau 6.2.2.1. |
ANSI/CSA | ANSI Z21.22-2015/CSA 4.4-2015 | Relief Valves For Hot Water Supply Systems | NPC 2.2.10.11.(1) CNP 2.2.10.11. 1) |
ANSI/CSA | ANSI Z21.47-2016/CSA 2.3-2016 | Gas-fired central furnaces | NBC Table 9.36.3.10. CNB Tableau 9.36.3.10. NECB Table 5.2.12.1.O CNÉB Tableau 5.2.12.1.-O |
ANSI/CSA | ANSI Z21.50-2016/CSA 2.22-2016 | Vented decorative gas appliances | NBC Table 9.36.3.10. CNB Tableau 9.36.3.10. |
ANSI/CSA | ANSI Z21.56-2017/CSA 4.7-2017 | Gas-fired pool heaters | NBC Table 9.36.4.2. CNB Tableau 9.36.4.2. NECB Table 6.2.2.1. CNÉB Tableau 6.2.2.1. |
ANSI/CSA | ANSI Z83.8-2016/CSA 2.6-2016 | Gas unit heaters, gas packaged heaters, gas utility heaters and gas-fired duct furnaces | NBC Table 9.36.3.10. CNB Tableau 9.36.3.10. NECB Table 5.2.12.1.O CNÉB Tableau 5.2.12.1.-O |
APA | ANSI/APA PRG 320-2018 | Standard for Performance-Rated Cross-Laminated Timber | NBC 3.1.6.3.(3) CNB 3.1.6.3. 3) |
API | RP 1604 (1996) | Closure of Underground Petroleum Storage Tanks | NFC A-4.3.16.1.(1) CNPI A-4.3.16.1. 1) |
API | RP 2003 (2008) | Protection Against Ignitions Arising Out of Static, Lightning, and Stray Currents | NFC A-4.7.4.5. CNPI A-4.7.4.5. |
API | RP 2009 (2002) | Safe Welding, Cutting and Hot Work Practices in the Petroleum and Petrochemical Industries | NFC A-5.2.3.4.(1)(b) CNPI A-5.2.3.4. 1)b) |
API | RP 2200 (2010) | Repairing Crude Oil, Liquefied Petroleum Gas, and Product Pipelines | NFC A-4.5.10.7.(6) CNPI A-4.5.10.7. 6) |
API | RP 2201 (2003) | Safe Hot Tapping Practices in the Petroleum and Petrochemical Industries | NFC A-4.5.10.7.(6) NFC A-5.2.3.4.(1)(b) CNPI A-4.5.10.7. 6) CNPI A-5.2.3.4. 1)b) |
API | RP 2207 (2007) | Preparing Tank Bottoms for Hot Work | NFC A-5.2.3.4.(1)(b) CNPI A-5.2.3.4. 1)b) |
API | SPEC 12B (2008) | Specification for Bolted Tanks for Storage of Production Liquids | NFC 4.3.1.2.(1) NFC A-4.3.1.2.(2)(b) CNPI 4.3.1.2. 1) CNPI A-4.3.1.2. 2)b) |
API | SPEC 12D (2008) | Specification for Field Welded Tanks for Storage of Production Liquids | NFC 4.3.1.2.(1) NFC A-4.3.1.2.(2)(b) CNPI 4.3.1.2. 1) CNPI A-4.3.1.2. 2)b) |
API | SPEC 12F (2008) | Specification for Shop Welded Tanks for Storage of Production Liquids | NFC 4.3.1.2.(1) NFC A-4.3.1.2.(2)(b) CNPI 4.3.1.2. 1) CNPI A-4.3.1.2. 2)b) |
API | SPEC 5L (2012) | Line Pipe | NFC 4.5.2.1.(4) CNPI 4.5.2.1. 4) |
API | STD 1104 (2013) | Welding of Pipelines and Related Facilities | NFC 4.5.5.2.(1) NFC A-4.5.10.7.(6) CNPI 4.5.5.2. 1) CNPI A-4.5.10.7. 6) |
API | STD 2000 (2009) | Venting Atmospheric and Low-Pressure Storage Tanks | NFC 4.3.1.2.(2) NFC 4.3.4.1.(1) NFC A-4.3.13.10.(1) CNPI 4.3.1.2. 2) CNPI 4.3.4.1. 1) CNPI A-4.3.13.10. 1) |
API | STD 2015 (2001) | Requirements for Safe Entry and Cleaning of Petroleum Storage Tanks, Planning and Managing Tank Entry From Decommissioning Through Recommissioning | NFC A-5.2.3.4.(1)(b) CNPI A-5.2.3.4. 1)b) |
API | STD 620 (2013) | Design and Construction of Large, Welded, Low-Pressure Storage Tanks | NFC 4.3.1.3.(1) CNPI 4.3.1.3. 1) |
API | STD 650 (2013) | Welded Tanks for Oil Storage | NFC 4.3.1.2.(1) CNPI 4.3.1.2. 1) |
API | STD 653 (2009) | Tank Inspection, Repair, Alteration, and Reconstruction | NFC 4.3.1.10.(2) NFC Table 4.4.1.2.B CNPI 4.3.1.10. 2) CNPI Tableau 4.4.1.2.B |
ARPM | IP-2-2014 | Hose Handbook | NFC A-4.8.8.1.(1)(a) CNPI A-4.8.8.1. 1)a) |
ASABE | ANSI/ASABE AD11684:1995 | Tractors, machinery for agricultural and forestry, powered lawn and garden equipment — Safety signs and hazard pictorials — General principles | NFC A-2.14.2. CNPI A-2.14.2. |
ASCE | ASCE/SEI (49-12) | Wind Tunnel Testing for Buildings and Other Structures | NBC 4.1.7.14.(1) CNB 4.1.7.14. 1) |
ASCE | ASCE/SEI (7-10) | Minimum Design Loads for Buildings and Other Structures | NBC A-4.1.8.18.(14) and (15) NBC A-9.4.2.1. and 9.4.2.2. CNB A-4.1.8.18. 14) et 15) CNB A-9.4.2.1. et 9.4.2.2. |
ASCE | ASCE/SEI (8-02) | Specification for the Design of Cold-Formed Stainless Steel Structural Members | NBC A-4.3.4.2.(1) CNB A-4.3.4.2. 1) |
ASHRAE | ANSI/ASHRAE 111-2008 | Testing, Adjusting, and Balancing of Building HVAC Systems | NECB A-5.2.5.2.(1) CNÉB A-5.2.5.2. 1) |
ASHRAE | ANSI/ASHRAE 140- |
NECB 8.4.2.2.(4) CNÉB 8.4.2.2. 4) |
|
ASHRAE | ANSI/ASHRAE 140-2011 | Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs | NBC 9.36.5.4.(8) CNB 9.36.5.4. 8) |
ASHRAE | ANSI/ASHRAE 188-2015 | Legionellosis: Risk Management for Building Water Systems | NBC A-6.2.1.1. CNB A-6.2.1.1. |
ASHRAE | ANSI/ASHRAE 55-2013 | Thermal Environmental Conditions for Human Occupancy | NECB A-5.2.8.3.(1) CNÉB A-5.2.8.3. 1) |
ASHRAE | ANSI/ASHRAE 62.1-2016 | Ventilation for Acceptable Indoor Air Quality | NBC 6.3.1.1.(2) NBC 6.3.1.1.(3) NBC 6.3.2.2.(1) CNB 6.3.1.1. 2) CNB 6.3.1.1. 3) CNB 6.3.2.2. 1) NECB A-5.2.3.4.(1) CNÉB A-5.2.3.4. 1) |
ASHRAE | ANSI/ASHRAE 62-2001 | Ventilation for Acceptable Indoor Air Quality (except Addendum n) | NBC A-9.25.5.2. |
ASHRAE | ANSI/ASHRAE 62-2001 | Ventilation for Acceptable Indoor Air Quality (sauf l'addenda n) | CNB A-9.25.5.2. |
ASHRAE | ANSI/ASHRAE 84-2013 | Method of Testing Air-to-Air Heat/Energy Exchangers | NECB 5.2.10.1.(5) CNÉB 5.2.10.1. 5) |
ASHRAE | Guideline 12-2000 | Minimizing the Risk of Legionellosis Associated with Building Water Systems | NBC 6.2.1.1.(1) NBC 6.3.2.15.(9) NBC 6.3.2.16.(1) CNB 6.2.1.1. 1) CNB 6.3.2.15. 9) CNB 6.3.2.16. 1) |
ASHRAE | RP-1365-2011 | Thermal Performance of Building Envelope Details for Mid- and High-Rise Buildings | NECB A-3.1.1.5.(5)(a) CNÉB A-3.1.1.5. 5)a) |
ASHRAE | 1997 | ASHRAE Handbook – Fundamentals | NBC A-9.32.3.11. CNB A-9.32.3.11. |
ASHRAE | 2011 | ASHRAE Handbook – HVAC Applications | NBC A-2.4.2.1.(1) CNB A-2.4.2.1. 1) NPC A-2.6.3.1.(2) CNP A-2.6.3.1. 2) NECB A-6.2.4.1.(1) CNÉB A-6.2.4.1. 1) |
ASHRAE | 2013 | ASHRAE Handbook – Fundamentals | NBC A-9.36.2.4.(1) NBC Table A-9.36.2.4.(1)D CNB A-9.36.2.4. 1) CNB Tableau A-9.36.2.4. 1)D NPC A-2.6.3.1.(2) CNP A-2.6.3.1. 2) NECB 3.1.1.5.(4) NECB 3.1.1.5.(5) NECB A-8.4.4.4.(1) CNÉB 3.1.1.5. 4) CNÉB 3.1.1.5. 5) CNÉB A-8.4.4.4. 1) |
ASHRAE/IES | ANSI/ASHRAE/IES 90.1-2013 | Energy Standard for Buildings Except Low-Rise Residential Buildings | NECB A-5.2.3.4.(2) NECB A-Table 3.2.2.2. CNÉB A-5.2.3.4. 2) CNÉB A-Tableau 3.2.2.2. |
ASHRAE/IES | 90.1-2013 | User's Manual | NECB A-5.2.10.1.(4) NECB A-5.2.10.4.(5) NECB A-6.2.3.1.(1) CNÉB A-5.2.10.1. 4) CNÉB A-5.2.10.4. 5) CNÉB A-6.2.3.1. 1) |
ASME | BPVC- |
Boiler and Pressure Vessel Code | NFC 4.3.1.3.(1) NFC 4.5.9.5.(2) NFC 4.5.9.6.(1) CNPI 4.3.1.3. 1) CNPI 4.5.9.5. 2) CNPI 4.5.9.6. 1) |
ASME | B16.12-2009 | Cast Iron Threaded Drainage Fittings | NPC 2.2.6.3.(1) CNP 2.2.6.3. 1) |
ASME | B16.15-2018 | Cast Copper Alloy Threaded Fittings: Classes 125 and 250 | NPC 2.2.7.3.(1) NPC A-2.2.5. to 2.2.8. CNP 2.2.7.3. 1) CNP A-2.2.5. à 2.2.8. |
ASME | B16.18-2018 | Cast Copper Alloy Solder-Joint Pressure Fittings | NPC 2.2.7.6.(1) NPC 2.2.7.6.(2) NPC A-2.2.5. to 2.2.8. CNP 2.2.7.6. 1) CNP 2.2.7.6. 2) CNP A-2.2.5. à 2.2.8. |
ASME | B16.22-2018 | Wrought Copper and Copper Alloy Solder-Joint Pressure Fittings | NPC 2.2.7.6.(1) NPC A-2.2.5. to 2.2.8. CNP 2.2.7.6. 1) CNP A-2.2.5. à 2.2.8. |
ASME | B16.23- |
Cast Copper Alloy Solder Joint Drainage Fittings: DWV | NPC 2.2.7.5.(1) NPC A-2.2.5. to 2.2.8. CNP 2.2.7.5. 1) CNP A-2.2.5. à 2.2.8. |
ASME | B16.24- |
Cast Copper Alloy Pipe Flanges, Flanged Fittings, and Valves: Classes 150, 300, 600, 900, 1500, and 2500 | NPC 2.2.7.2.(1) CNP 2.2.7.2. 1) |
ASME | B16.26-2018 | Cast Copper Alloy Fittings for Flared Copper Tubes | NPC 2.2.7.7.(1) NPC 2.2.7.7.(2) CNP 2.2.7.7. 1) CNP 2.2.7.7. 2) |
ASME | B16.29- |
Wrought Copper and Wrought Copper Alloy Solder-Joint Drainage Fittings – DWV | NPC 2.2.7.5.(1) NPC A-2.2.5. to 2.2.8. CNP 2.2.7.5. 1) CNP A-2.2.5. à 2.2.8. |
ASME | B16.3-2016 | Malleable Iron Threaded Fittings: Classes 150 and 300 | NPC 2.2.6.6.(1) NPC A-2.2.5. to 2.2.8. CNP 2.2.6.6. 1) CNP A-2.2.5. à 2.2.8. |
ASME | B16.4-2016 | Gray Iron Threaded Fittings: Classes 125 and 250 | NPC 2.2.6.5.(1) NPC A-2.2.5. to 2.2.8. CNP 2.2.6.5. 1) CNP A-2.2.5. à 2.2.8. |
ASME | B16.5-2017 | Pipe Flanges and Flanged Fittings: NPS ½ through NPS 24 Metric/Inch Standard | NFC 4.5.5.3.(1) CNPI 4.5.5.3. 1) NPC 2.2.6.12.(1) CNP 2.2.6.12. 1) |
ASME | B16.9-2018 | Factory-Made Wrought Buttwelding Fittings | NPC 2.2.6.11.(1) NPC 2.2.6.14.(1) CNP 2.2.6.11. 1) CNP 2.2.6.14. 1) |
ASME | B18.6.1-1981 | Wood Screws (Inch Series) | NBC 9.23.3.1.(3) NBC A-9.23.3.1.(3) NBC Table 5.9.1.1. CNB 9.23.3.1. 3) CNB A-9.23.3.1. 3) CNB Tableau 5.9.1.1. |
ASME | B31.3- |
Process Piping | NFC 4.5.2.1.(5) CNPI 4.5.2.1. 5) |
ASME | B31.9-2017 | Building Services Piping | NPC 2.3.2.8.(1) CNP 2.3.2.8. 1) |
ASME | B36. |
Welded and Seamless Wrought Stainless Steel Pipe | NPC 2.2.6.10.(1) CNP 2.2.6.10. 1) |
ASME/CSA | ASME A112.18.1-2018/CSA B125.1-18 | Plumbing Supply Fittings | NPC 2.2.10.6.(1) NPC 2.2.10.7.(1) CNP 2.2.10.6. 1) CNP 2.2.10.7. 1) NECB 6.2.6.1.(1) NECB 6.2.6.2.(1) CNÉB 6.2.6.1. 1) CNÉB 6.2.6.2. 1) |
ASME/CSA | ASME A112.18.2-2015/CSA B125.2-15 | Plumbing Waste Fittings | NPC 2.2.10.6.(6) NPC 2.2.3.3.(1) CNP 2.2.10.6. 6) CNP 2.2.3.3. 1) |
ASME/CSA | ASME A112.18.6-2017/CSA B125.6-17 | Flexible water connectors | NPC 2.2.10.18.(1) CNP 2.2.10.18. 1) |
ASME/CSA | ASME A112.19.1- |
Enamelled |
NPC 2.2.2.2.(1) CNP 2.2.2.2. 1) |
ASME/CSA | ASME A112.19.2-2018/CSA B45.1-18 | Ceramic Plumbing Fixtures | NPC 2.2.2.2.(1) CNP 2.2.2.2. 1) |
ASME/CSA | ASME A112.19.3- |
Stainless |
NPC 2.2.2.2.(1) CNP 2.2.2.2. 1) |
ASME/CSA | ASME A112.19.7-2012/CSA B45.10-12 | Hydromassage Bathtub Systems | NPC 2.2.2.2.(1) CNP 2.2.2.2. 1) |
ASME/CSA | ASME A112.3.4-2018/CSA B45.9-18 | Macerating Toilet Systems and Waste-Pumping Systems for Plumbing Fixtures | NPC 2.2.2.2.(1) CNP 2.2.2.2. 1) |
ASME/CSA | ASME A112.4.14- |
Manually |
NPC 2.2.10.6.(7) CNP 2.2.10.6. 7) |
ASME/CSA | ASME A112.4.2- |
Personal hygiene devices for water closets | NPC 2.2.2.2.(1) CNP 2.2.2.2. 1) |
ASME/CSA | ASME A17.1- |
Safety Code for Elevators and Escalators | NBC 3.2.6.7.(2) NBC 3.5.2.1.(1) NBC 3.5.2.1.(2) NBC 3.5.2.1.(3) NBC 3.5.4.1.(2) NBC 3.5.4.2.(1) NBC A-3.5.2.1.(1) NBC Table 4.1.5.11. NBC Table 4.1.8.18. NFC 7.2.2.1.(2) |
ASME/CSA | ASME A17.1- |
Safety Code |
CNB 3.2.6.7. 2) CNB 3.5.2.1. 1) CNB 3.5.2.1. 2) CNB 3.5.2.1. 3) CNB 3.5.4.1. 2) CNB 3.5.4.2. 1) CNB A-3.5.2.1. 1) CNB Tableau 4.1.5.11. CNB Tableau 4.1.8.18. CNPI 7.2.2.1. 2) |
ASPE | 2010 | Plumbing Engineering Design Handbook, Volume 2 | NPC A-2.6.3.1.(2) CNP A-2.6.3.1. 2) |
ASPE | Plumbing Engineering Design Handbook |
NPC A-2.4.4.3.(1) CNP A-2.4.4.3. 1) |
|
ASPE/ANSI | 63-2013 | Rainwater Catchment Systems | NPC A-2.7.2.4.(1) CNP A-2.7.2.4. 1) |
ASSE | ANSI/ASSE 1010-2004 | Water Hammer Arresters | NPC 2.2.10.15.(1) CNP 2.2.10.15. 1) |
ASSE | 1051-2009 | Individual and Branch Type Air Admittance Valves for Sanitary Drainage Systems | NPC 2.2.10.16.(1) CNP 2.2.10.16. 1) |
ASSE/CSA | ASSE 1002- |
Anti-siphon fill valves for water closet tanks | NPC 2.2.10.10.(2) CNP 2.2.10.10. 2) |
ASSE/CSA | ASSE 1016-2017/ASME A112.1016-2017/CSA B125.16-17 | Performance Requirements for Automatic Compensating Valves for Individual Showers and Tub/Shower Combinations | NPC 2.2.10.7.(1) NPC A-2.2.10.6.(3) CNP 2.2.10.7. 1) CNP A-2.2.10.6. 3) |
ASSE/CSA | ASSE 1037- |
Performance requirements for pressurized flushing devices for plumbing fixtures | NPC 2.2.10.8.(1) CNP 2.2.10.8. 1) |
ASSE/CSA | ASSE 1070- |
Performance requirements for water temperature limiting devices | NPC 2.2.10.7.(2) CNP 2.2.10.7. 2) |
ASTM | A1008/A1008M-18 | Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardenable | NBC 4.2.3.8.(1) CNB 4.2.3.8. 1) |
ASTM | A1011/A1011M-18a | Standard Specification for Steel, Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, and Ultra-High Strength | NBC 4.2.3.8.(1) CNB 4.2.3.8. 1) |
ASTM | A123/A123M-17 | Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products | NBC Table 5.9.1.1. NBC Table 9.20.16.1. CNB Tableau 5.9.1.1. CNB Tableau 9.20.16.1. |
ASTM | A153/A153M-16a | Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware | NBC 9.23.2.4.(2) NBC Table 5.9.1.1. NBC Table 9.20.16.1. CNB 9.23.2.4. 2) CNB Tableau 5.9.1.1. CNB Tableau 9.20.16.1. |
ASTM | A182/A182M-19 | Standard Specification for Forged or Rolled Alloy and Stainless Steel Pipe Flanges, Forged Fittings, and Valves and Parts for High-Temperature Service | NPC 2.2.6.12.(1) NPC 2.2.6.13.(1) CNP 2.2.6.12. 1) CNP 2.2.6.13. 1) |
ASTM | A193/A193M-17 | Standard Specification for Alloy-Steel and Stainless Steel Bolting for High Temperature or High Pressure Service and Other Special Purpose Applications | NFC 4.5.5.4.(1) CNPI 4.5.5.4. 1) |
ASTM | A252-10 | Standard Specification for Welded and Seamless Steel Pipe Piles | NBC 4.2.3.8.(1) CNB 4.2.3.8. 1) |
ASTM | A269/A269M-15a | Standard Specification for Seamless and Welded Austenitic Stainless Steel Tubing for General Service | NPC 2.2.6.14.(1) NPC A-2.2.5. to 2.2.8. CNP 2.2.6.14. 1) CNP A-2.2.5. à 2.2.8. |
ASTM | A283/A283M-18 | Standard Specification for Low and Intermediate Tensile Strength Carbon Steel Plates | NBC 4.2.3.8.(1) CNB 4.2.3.8. 1) |
ASTM | A312/A312M-18a | Standard Specification for Seamless, Welded, and Heavily Cold Worked Austenitic Stainless Steel Pipes | NPC 2.2.6.10.(1) NPC A-2.2.5. to 2.2.8. CNP 2.2.6.10. 1) CNP A-2.2.5. à 2.2.8. |
ASTM | A351/A351M-18 | Standard Specification for Castings, Austenitic, for Pressure-Containing Parts | NPC 2.2.6.13.(1) CNP 2.2.6.13. 1) |
ASTM | A390-06 | Standard Specification for Zinc-Coated (Galvanized) Steel Poultry Fence Fabric (Hexagonal and Straight Line) | NBC Table 9.10.3.1.-B CNB Tableau 9.10.3.1.-B |
ASTM | A403/A403M- |
Standard Specification for Wrought Austenitic Stainless Steel Piping Fittings | NPC 2.2.6.11.(1) CNP 2.2.6.11. 1) |
ASTM | A518/A518M-99 | Standard Specification for Corrosion-Resistant High-Silicon Iron Castings | NPC 2.2.8.1.(1) CNP 2.2.8.1. 1) |
ASTM | A53/A53M- |
Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless | NFC 4.5.2.1.(4) CNPI 4.5.2.1. 4) NPC 2.2.6.7.(4) NPC A-2.2.5. to 2.2.8. CNP 2.2.6.7. 4) CNP A-2.2.5. à 2.2.8. |
ASTM | A653/A653M- |
Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process | NBC 9.23.2.4.(1) NBC 9.3.3.2.(1) NBC Table 5.9.1.1. CNB 9.23.2.4. 1) CNB 9.3.3.2. 1) CNB Tableau 5.9.1.1. |
ASTM | A792/A792M- |
Standard Specification for Steel Sheet, 55% Aluminum-Zinc Alloy-Coated by the Hot-Dip Process | NBC 9.3.3.2.(1) CNB 9.3.3.2. 1) |
ASTM | B306-13 | Standard Specification for Copper Drainage Tube (DWV) | NPC 2.2.7.4.(1) NPC A-2.2.5. to 2.2.8. CNP 2.2.7.4. 1) CNP A-2.2.5. à 2.2.8. |
ASTM | B32-08 | Standard Specification for Solder Metal | NPC 2.2.9.2.(1) CNP 2.2.9.2. 1) |
ASTM | B42-15a | Standard Specification for Seamless Copper Pipe, Standard Sizes | NPC 2.2.7.1.(1) NPC A-2.2.5. to 2.2.8. CNP 2.2.7.1. 1) CNP A-2.2.5. à 2.2.8. |
ASTM | B43-15 | Standard Specification for Seamless Red Brass Pipe, Standard Sizes | NPC 2.2.7.1.(2) NPC A-2.2.5. to 2.2.8. CNP 2.2.7.1. 2) CNP A-2.2.5. à 2.2.8. |
ASTM | B813-16 | Standard Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube | NPC 2.2.9.2.(3) CNP 2.2.9.2. 3) |
ASTM | B828-16 | Standard Specification for Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings | NPC 2.3.2.4.(1) CNP 2.3.2.4. 1) |
ASTM | B88- |
Standard Specification for Seamless Copper Water Tube | NPC 2.2.7.4.(1) NPC A-2.2.5. to 2.2.8. CNP 2.2.7.4. 1) CNP A-2.2.5. à 2.2.8. |
ASTM | C1002-07 | Standard Specification for Steel Self-Piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs | NBC 9.24.1.4.(1) NBC 9.29.5.7.(1) NBC Table 5.9.1.1. CNB 9.24.1.4. 1) CNB 9.29.5.7. 1) CNB Tableau 5.9.1.1. |
ASTM | C1053-00 | Standard Specification for Borosilicate Glass Pipe and Fittings for Drain, Waste, and Vent (DWV) Applications | NPC 2.2.8.1.(1) CNP 2.2.8.1. 1) |
ASTM | C1055-03 | Standard Guide for Heated System Surface Conditions that Produce Contact Burn Injuries | NBC A-6.5.1.1.(3) CNB A-6.5.1.1. 3) |
ASTM | C1177/C1177M-17 | Standard Specification for Glass Mat Gypsum Substrate for Use as Sheathing | NBC 3.1.5.14.(6) NBC 3.1.5.15.(4) NBC A-9.27.14.2.(2)(a) NBC Table 5.9.1.1. NBC Table 9.23.17.2.A CNB 3.1.5.14. 6) CNB 3.1.5.15. 4) CNB A-9.27.14.2. 2)a) CNB Tableau 5.9.1.1. CNB Tableau 9.23.17.2.A |
ASTM | C1178/C1178M-18 | Standard Specification for Coated Glass Mat Water-Resistant Gypsum Backing Panel | NBC 3.1.5.14.(6) NBC 3.1.5.15.(4) NBC 9.29.5.2.(1) NBC Table 5.9.1.1. CNB 3.1.5.14. 6) CNB 3.1.5.15. 4) CNB 9.29.5.2. 1) CNB Tableau 5.9.1.1. |
ASTM | C1184-18e1 | Standard Specification for Structural Silicone Sealants | NBC 9.27.4.2.(2) NBC Table 5.9.1.1. CNB 9.27.4.2. 2) CNB Tableau 5.9.1.1. |
ASTM | C1193-16 | Standard Specification for Use of Joint Sealants | NBC A-9.27.4.2.(1) NBC A-Table 5.9.1.1. CNB A-9.27.4.2. 1) CNB A-Tableau 5.9.1.1. |
ASTM | C126-13 | Ceramic Glazed Structural Clay Facing Tile, Facing Brick, and Solid Masonry Units | NBC 9.20.2.1.(1) NBC Table 5.9.1.1. CNB 9.20.2.1. 1) CNB Tableau 5.9.1.1. |
ASTM | C1280-13 | Standard Specification for Application of Exterior Gypsum Panel Products for Use as Sheathing | NBC Table 5.9.1.1. CNB Tableau 5.9.1.1. |
ASTM | C1299-03 | Standard Guide for Use in Selection of Liquid-Applied Sealants | NBC A-9.27.4.2.(1) CNB A-9.27.4.2. 1) |
ASTM | C1311-14 | Standard Specification for Solvent Release Sealants | NBC 9.27.4.2.(2) NBC Table 5.9.1.1. CNB 9.27.4.2. 2) CNB Tableau 5.9.1.1. |
ASTM | C1330-18 | Standard Specification for Cylindrical Sealant Backing for Use with Cold Liquid-Applied Sealants | NBC 9.27.4.2.(3) NBC Table 5.9.1.1. CNB 9.27.4.2. 3) CNB Tableau 5.9.1.1. |
ASTM | C1363-11 | Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus | NBC 9.36.2.2.(4) NBC A-5.9.4.1.(1) CNB 9.36.2.2. 4) CNB A-5.9.4.1. 1) NECB 3.1.1.5.(4) NECB 3.1.1.5.(5) CNÉB 3.1.1.5. 4) CNÉB 3.1.1.5. 5) |
ASTM | C1396/C1396M-17 | Standard Specification for Gypsum Board | NBC 3.1.5.14.(6) NBC 3.1.5.15.(4) NBC 3.1.6.15.(1) NBC 3.1.6.6.(2) NBC 9.29.5.2.(1) NBC D-1.5.1. NBC D-3.1.1. NBC Table 5.9.1.1. NBC Table 9.23.17.2.A NBC Table 9.29.5.3. CNB 3.1.5.14. 6) CNB 3.1.5.15. 4) CNB 3.1.6.15. 1) CNB 3.1.6.6. 2) CNB 9.29.5.2. 1) CNB D-1.5.1. CNB D-3.1.1. CNB Tableau 5.9.1.1. CNB Tableau 9.23.17.2.A CNB Tableau 9.29.5.3. |
ASTM | C1472-16 | Standard Guide for Calculating Movement and Other Effects When Establishing Sealant Joint Width | NBC A-9.27.4.2.(1) NBC A-Table 5.9.1.1. CNB A-9.27.4.2. 1) CNB A-Tableau 5.9.1.1. |
ASTM | C1658/C1658M-18 | Standard Specification for Glass Mat Gypsum Panels | NBC 3.1.5.14.(6) NBC Table 5.9.1.1. CNB 3.1.5.14. 6) CNB Tableau 5.9.1.1. |
ASTM | C177-19 | Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus | NBC 9.36.2.2.(1) CNB 9.36.2.2. 1) NECB 3.1.1.5.(1) CNÉB 3.1.1.5. 1) |
ASTM | C212-17 | Standard Specification for Structural Clay Facing Tile | NBC 9.20.2.1.(1) NBC Table 5.9.1.1. CNB 9.20.2.1. 1) CNB Tableau 5.9.1.1. |
ASTM | C260/C260M-10a | Standard Specification for Air-Entraining Admixtures for Concrete | NBC 9.3.1.8.(1) CNB 9.3.1.8. 1) |
ASTM | C27-98 | Standard Classification of Fireclay and High-Alumina Refractory Brick | NBC 9.21.3.4.(1) CNB 9.21.3.4. 1) |
ASTM | C330/C330M-17 | Standard Specification for Lightweight Aggregates for Structural Concrete | NBC D-1.4.3. CNB D-1.4.3. |
ASTM | C335/C335M-17 | Standard Test Method for Steady-State Heat Transfer Properties of Pipe Insulation | NECB 5.2.5.3.(6) NECB 6.2.3.1.(4) CNÉB 5.2.5.3. 6) CNÉB 6.2.3.1. 4) |
ASTM | C4-04 | Standard Specification for Clay Drain Tile and Perforated Clay Drain Tile | NBC 9.14.3.1.(1) NBC Table 5.9.1.1. CNB 9.14.3.1. 1) CNB Tableau 5.9.1.1. |
ASTM | C411-19 | Standard Specification for Hot-Surface Performance of High-Temperature Thermal Insulation | NBC 3.6.5.4.(4) NBC 3.6.5.5.(1) NBC 9.33.6.4.(4) NBC 9.33.8.2.(2) CNB 3.6.5.4. 4) CNB 3.6.5.5. 1) CNB 9.33.6.4. 4) CNB 9.33.8.2. 2) |
ASTM | C412M-15 | Standard Specification for Concrete Drain Tile | NBC 9.14.3.1.(1) NBC Table 5.9.1.1. CNB 9.14.3.1. 1) CNB Tableau 5.9.1.1. |
ASTM | C444M-17 | Standard Specification for Perforated Concrete Pipe | NBC 9.14.3.1.(1) NBC Table 5.9.1.1. CNB 9.14.3.1. 1) CNB Tableau 5.9.1.1. |
ASTM | C494/C494M- |
Standard Specification for Chemical Admixtures for Concrete | NBC 9.3.1.8.(1) CNB 9.3.1.8. 1) |
ASTM | C516-08e1 | Standard Specification for Vermiculite Loose Fill Thermal Insulation | NBC A-9.25.2.4.(5) CNB A-9.25.2.4. 5) |
ASTM | C518-17 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus | NBC 9.36.2.2.(1) CNB 9.36.2.2. 1) NECB 3.1.1.5.(1) CNÉB 3.1.1.5. 1) |
ASTM | C553-13 | Standard Specification for Mineral Fiber Blanket Thermal Insulation for Commercial and Industrial Applications | NBC Table 5.9.1.1. CNB Tableau 5.9.1.1. |
ASTM | C612-14 | Standard Specification for Mineral Fiber Block and Board Thermal Insulation | NBC Table 5.9.1.1. CNB Tableau 5.9.1.1. |
ASTM | C700-18 | Standard Specification for Vitrified Clay Pipe, Extra Strength, Standard Strength, and Perforated | NBC 9.14.3.1.(1) NBC Table 5.9.1.1. CNB 9.14.3.1. 1) CNB Tableau 5.9.1.1. |
ASTM | C726-17 | Standard Specification for Mineral Wool Roof Insulation Board | NBC 9.25.2.2.(1) NBC Table 5.9.1.1. CNB 9.25.2.2. 1) CNB Tableau 5.9.1.1. |
ASTM | C73-17 | Standard Specification for Calcium Silicate Brick (Sand-Lime Brick) | NBC 9.20.2.1.(1) NBC Table 5.9.1.1. CNB 9.20.2.1. 1) CNB Tableau 5.9.1.1. |
ASTM | C754-18 | Standard Specification for Installation of Steel Framing Members to Receive Screw-Attached Gypsum Panel Products | NBC Table A-9.11.1.4.A NBC Table A-9.11.1.4.B NBC Table A-9.11.1.4.C NBC Table A-9.11.1.4.D CNB Tableau A-9.11.1.4.A CNB Tableau A-9.11.1.4.B CNB Tableau A-9.11.1.4.C CNB Tableau A-9.11.1.4.D |
ASTM | C834-17 | Standard Specification for Latex Sealants | NBC 9.27.4.2.(2) NBC Table 5.9.1.1. CNB 9.27.4.2. 2) CNB Tableau 5.9.1.1. |
ASTM | C840-18b | Standard Specification for Application and Finishing of Gypsum Board | NBC 3.1.6.6.(2) NBC 9.29.5.1.(3) NBC A-9.29.5.1.(3) NBC D-2.3.9. NBC Table 5.9.1.1. CNB 3.1.6.6. 2) CNB 9.29.5.1. 3) CNB A-9.29.5.1. 3) CNB D-2.3.9. CNB Tableau 5.9.1.1. |
ASTM | C920-18 | Standard Specification for Elastomeric Joint Sealants | NBC 9.27.4.2.(2) NBC Table 5.9.1.1. CNB 9.27.4.2. 2) CNB Tableau 5.9.1.1. |
ASTM | C954-18 | Standard Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs from 0.033 in. (0.84 mm) to 0.112 in. (2.84 mm) in Thickness | NBC 9.24.1.4.(1) CNB 9.24.1.4. 1) |
ASTM | C991-16 | Standard Specification for Flexible Fibrous Glass Insulation for Metal Buildings | NBC Table 5.9.1.1. CNB Tableau 5.9.1.1. |
ASTM | D1037-12 | Standard Test Methods for Evaluating Properties of Wood-Base Fiber and Particle Panel Materials | NBC A-9.23.15.2.(4) CNB A-9.23.15.2. 4) |
ASTM | D1143/D1143M-07 | Standard Test Methods for Deep Foundations Under Static Axial Compressive Load | NBC A-4.2.7.2.(2) CNB A-4.2.7.2. 2) |
ASTM | D1227/D1227M-13 | Standard Specification for Emulsified Asphalt Used as a Protective Coating for Roofing | NBC 9.13.2.2.(2) NBC 9.13.3.2.(2) NBC Table 5.9.1.1. CNB 9.13.2.2. 2) CNB 9.13.3.2. 2) CNB Tableau 5.9.1.1. |
ASTM | D1761-12 | Standard Test Methods for Mechanical Fasteners in Wood and Wood-Based Materials | NBC A-9.27.5.4.(2) CNB A-9.27.5.4. 2) |
ASTM | D2178/D2178M-13a | Standard Specification for Asphalt Glass Felt Used in Roofing and Waterproofing | NBC Table 5.9.1.1. CNB Tableau 5.9.1.1. |
ASTM | D2466-17 | Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40 | NPC 2.2.5.7.(2) NPC A-2.2.5. to 2.2.8. CNP 2.2.5.7. 2) CNP A-2.2.5. à 2.2.8. |
ASTM | D2467-15 | Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80 | NPC 2.2.5.7.(2) NPC A-2.2.5. to 2.2.8. CNP 2.2.5.7. 2) CNP A-2.2.5. à 2.2.8. |
ASTM | D2898-10 | Standard Practice for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing | NBC 3.1.4.8.(3) NBC 3.1.5.24.(1) NBC 3.1.5.5.(3) NBC 3.1.6.9.(6) NBC 3.2.3.7.(4) NBC 9.10.14.5.(3) NBC 9.10.15.5.(3) NBC D-6.1.1. CNB 3.1.4.8. 3) CNB 3.1.5.24. 1) CNB 3.1.5.5. 3) CNB 3.1.6.9. 6) CNB 3.2.3.7. 4) CNB 9.10.14.5. 3) CNB 9.10.15.5. 3) CNB D-6.1.1. |
ASTM | D3019/D3019M-17 | Standard Specification for Lap Cement Used with Asphalt Roll Roofing, Non-Fibered, and Fibered | NBC 9.13.3.2.(2) NBC Table 5.9.1.1. NBC Table 9.26.2.1.B CNB 9.13.3.2. 2) CNB Tableau 5.9.1.1. CNB Tableau 9.26.2.1.B |
ASTM | D3138-04 | Standard Specification for Solvent Cements for Transition Joints Between Acrylonitrile-Butadiene-Styrene (ABS) and Poly(Vinyl Chloride) (PVC) Non-Pressure Piping Components | NPC A-2.2.5.9. to 2.2.5.11. CNP A-2.2.5.9. à 2.2.5.11. |
ASTM | D323-15a | Standard Test Method for Vapor Pressure of Petroleum Products (Reid Method) | NBC 1.4.1.2.(1) of Division A CNB 1.4.1.2. 1) de la division A NFC 1.4.1.2.(1) of Division A CNPI 1.4.1.2. 1) de la division A |
ASTM | D3261-16 | Standard Specification for Butt Heat Fusion Polyethylene (PE) Plastic Fittings for Polyethylene (PE) Plastic Pipe and Tubing | NPC 2.2.5.4.(3) CNP 2.2.5.4. 3) |
ASTM | D3278-96 | Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus | NFC 4.1.3.1.(4) NFC A-4.1.3.1. CNPI 4.1.3.1. 4) CNPI A-4.1.3.1. |
ASTM | D3679-17 | Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Siding | NBC 9.27.12.1.(1) CNB 9.27.12.1. 1) |
ASTM | D3828-16a | Standard Test Methods for Flash Point by Small Scale Closed Cup Tester | NFC 4.1.3.1.(3) CNPI 4.1.3.1. 3) |
ASTM | D4359-90 | Standard Test Method for Determining Whether a Material Is a Liquid or a Solid | NFC A-4.1.3.1. CNPI A-4.1.3.1. |
ASTM | D4477-16 | Standard Specification for Rigid (Unplasticized) Poly(Vinyl Chloride) (PVC) Soffit | NBC 9.27.12.1.(3) CNB 9.27.12.1. 3) |
ASTM | D4479/D4479M-07e1 | Standard Specification for Asphalt Roof Coatings – Asbestos-Free | NBC 9.13.2.2.(2) NBC 9.13.3.2.(2) NBC Table 5.9.1.1. NBC Table 9.26.2.1.B CNB 9.13.2.2. 2) CNB 9.13.3.2. 2) CNB Tableau 5.9.1.1. CNB Tableau 9.26.2.1.B |
ASTM | D4637/D4637M-15 | Standard Specification for EPDM Sheet Used In Single-Ply Roof Membrane | NBC 9.13.3.2.(2) NBC Table 5.9.1.1. NBC Table 9.26.2.1.B CNB 9.13.3.2. 2) CNB Tableau 5.9.1.1. CNB Tableau 9.26.2.1.B |
ASTM | D4811/D4811M-16 | Standard Specification for Nonvulcanized (Uncured) Rubber Sheet Used as Roof Flashing | NBC 9.13.3.2.(2) NBC Table 5.9.1.1. NBC Table 9.26.2.1.B CNB 9.13.3.2. 2) CNB Tableau 5.9.1.1. CNB Tableau 9.26.2.1.B |
ASTM | D5/D5M-19 | Standard Test Method for Penetration of Bituminous Materials | NFC A-4.1.3.1. CNPI A-4.1.3.1. |
ASTM | D5456-19 | Standard Specification for Evaluation of Structural Composite Lumber Products | NBC 3.1.11.7.(5) CNB 3.1.11.7. 5) |
ASTM | D56 |
Standard Test Method for Flash Point by Tag Closed Cup Tester | NFC 4.1.3.1.(1) CNPI 4.1.3.1. 1) |
ASTM | D6878/D6878M-11a | Standard Specification for Thermoplastic Polyolefin Based Sheet Roofing | NBC 9.13.3.2.(2) NBC Table 5.9.1.1. NBC Table 9.26.2.1.B CNB 9.13.3.2. 2) CNB Tableau 5.9.1.1. CNB Tableau 9.26.2.1.B |
ASTM | D7254-17 | Standard Specification for Polypropylene (PP) Siding | NBC 9.27.13.1.(1) CNB 9.27.13.1. 1) |
ASTM | D7793-17 | Standard Specification for Insulated Vinyl Siding | NBC 9.27.12.1.(2) CNB 9.27.12.1. 2) |
ASTM | D8052/D8052M- |
Standard Test Method for Quantification of Air Leakage in Low-Sloped Membrane Roof Assemblies | NBC A-5.4.1.2.(1) CNB A-5.4.1.2. 1) |
ASTM | D92-18 | Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester | NFC A-4.1.2.2. CNPI A-4.1.2.2. |
ASTM | D93-18 | Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester | NFC 4.1.3.1.(2) CNPI 4.1.3.1. 2) |
ASTM | E1007-19 | Standard Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures | NBC A-9.11. CNB A-9.11. |
ASTM | E1105-15 | Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference | NBC A-5.9.2.3.(1) NBC A-5.9.3.5.(2) CNB A-5.9.2.3. 1) CNB A-5.9.3.5. 2) |
ASTM | E1186-17 | Standard Practices for Air Leakage Site Detection in Building Envelopes and Air Barrier Systems | NBC A-5.4.1.2.(2) CNB A-5.4.1.2. 2) |
ASTM | E1300-16 | Standard Practice for Determining Load Resistance of Glass in Buildings | NBC 4.3.6.1.(1) NBC 9.6.1.3.(1) CNB 4.3.6.1. 1) CNB 9.6.1.3. 1) |
ASTM | E2190-19 | Standard Specification for Insulating Glass Unit Performance and Evaluation | NBC 9.6.1.2.(1) NBC Table 5.9.1.1. CNB 9.6.1.2. 1) CNB Tableau 5.9.1.1. |
ASTM | E2307-15b | Standard Test Method for Determining Fire Resistance of Perimeter Fire Barriers Using Intermediate-Scale, Multi-storey Test Apparatus | NBC 3.1.8.3.(4) NBC 9.10.9.2.(4) NBC A-3.1.8.3.(2) CNB 3.1.8.3. 4) CNB 9.10.9.2. 4) CNB A-3.1.8.3. 2) |
ASTM | E2357-18 | Standard Test Method for Determining Air Leakage Rate of Air Barrier Assemblies | NBC 9.36.2.9.(1) NBC A-5.4.1.1.(3) NBC A-9.36.2.9.(1) CNB 9.36.2.9. 1) CNB A-5.4.1.1. 3) CNB A-9.36.2.9. 1) |
ASTM | E283-04 | Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen | NBC 5.9.3.4.(2) NBC A-5.9.3.4.(2) CNB 5.9.3.4. 2) CNB A-5.9.3.4. 2) NECB 3.2.4.3.(3) NECB 3.2.4.3.(6) NECB 3.2.4.3.(7) NECB 3.2.4.3.(8) NECB 3.2.4.3.(9) CNÉB 3.2.4.3. 3) CNÉB 3.2.4.3. 6) CNÉB 3.2.4.3. 7) CNÉB 3.2.4.3. 8) CNÉB 3.2.4.3. 9) |
ASTM | E3158-18 | Standard Test Method for Measuring the Air Leakage Rate of a Large or Multizone Building | NECB 3.2.4.2.(1) CNÉB 3.2.4.2. 1) |
ASTM | E330/E330M-14 | Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference | NBC A-5.9.3.2.(1) CNB A-5.9.3.2. 1) |
ASTM | E331-00 | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference | NBC 5.9.3.5.(2) NBC A-5.9.3.5.(2) CNB 5.9.3.5. 2) CNB A-5.9.3.5. 2) |
ASTM | E336-11 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | NBC 5.8.1.2.(2) NBC 5.8.1.4.(7) NBC 9.11.1.2.(2) NBC A-9.11. CNB 5.8.1.2. 2) CNB 5.8.1.4. 7) CNB 9.11.1.2. 2) CNB A-9.11. |
ASTM | E413-16 | Classification for Rating Sound Insulation | NBC 5.8.1.2.(1) NBC 5.8.1.2.(2) NBC 5.8.1.4.(7) NBC 5.8.1.5.(3) NBC 9.11.1.2.(1) NBC 9.11.1.2.(2) NBC A-1.4.1.2.(1) of Division A CNB 5.8.1.2. 1) CNB 5.8.1.2. 2) CNB 5.8.1.4. 7) CNB 5.8.1.5. 3) CNB 9.11.1.2. 1) CNB 9.11.1.2. 2) CNB A-1.4.1.2. 1) de la division A |
ASTM | E492- |
Standard Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-Ceiling Assemblies Using the Tapping Machine | NBC A-9.11. CNB A-9.11. |
ASTM | E547-00 | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference | NBC 5.9.3.5.(2) NBC A-5.9.3.5.(2) CNB 5.9.3.5. 2) CNB A-5.9.3.5. 2) |
ASTM | E597-95 | Practice for Determining a Single Number Rating of Airborne Sound Insulation for Use in Multi-Unit Building Specifications | NBC A-9.11. CNB A-9.11. |
ASTM | E736/E736M-17 | Standard Test Method for Cohesion/Adhesion of Sprayed Fire-Resistive Materials Applied to Structural Members | NBC Table 9.10.3.1.-B CNB Tableau 9.10.3.1.-B |
ASTM | E779-10 | Standard Test Method for Determining Air Leakage Rate by Fan Pressurization | NECB 8.4.2.9.(2) CNÉB 8.4.2.9. 2) |
ASTM | E783-02 | Standard Test Method for Field Measurement of Air Leakage Through Installed Exterior Windows and Doors | NBC A-5.4.1.2.(2) NBC A-5.9.2.3.(1) NBC A-5.9.3.4.(2) CNB A-5.4.1.2. 2) CNB A-5.9.2.3. 1) CNB A-5.9.3.4. 2) |
ASTM | E90-09 | Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements | NBC 5.8.1.2.(1) NBC 5.8.1.4.(1) NBC 9.11.1.2.(1) CNB 5.8.1.2. 1) CNB 5.8.1.4. 1) CNB 9.11.1.2. 1) |
ASTM | E96/E96M-16 | Standard Test Methods for Water Vapor Transmission of Materials | NBC 5.5.1.2.(3) NBC 9.13.2.2.(2) NBC 9.25.4.2.(1) NBC 9.25.4.2.(2) NBC 9.25.5.1.(1) NBC 9.30.1.2.(1) CNB 5.5.1.2. 3) CNB 9.13.2.2. 2) CNB 9.25.4.2. 1) CNB 9.25.4.2. 2) CNB 9.25.5.1. 1) CNB 9.30.1.2. 1) |
ASTM | F1667-18a | Standard Specification for Driven Fasteners: Nails, Spikes, and Staples | NBC 9.23.3.1.(1) NBC 9.26.2.3.(1) NBC 9.29.5.6.(1) CNB 9.23.3.1. 1) CNB 9.26.2.3. 1) CNB 9.29.5.6. 1) |
ASTM | F2090-17 | Standard Specification for Window Fall Prevention Devices With Emergency Escape (Egress) Release Mechanisms | NBC A-9.8.8.1.(4) CNB A-9.8.8.1. 4) |
ASTM | F3128-19 | Standard Specification for Poly(Vinyl Chloride) (PVC) Schedule 40 Drain, Waste, and Vent Pipe with a Cellular Core | NPC 2.2.5.16.(1) NPC A-2.2.5. to 2.2.8. CNP 2.2.5.16. 1) CNP A-2.2.5. à 2.2.8. |
ASTM | F476-14 | Standard Test Methods for Security of Swinging Door Assemblies | NBC 9.7.5.2.(2) NBC A-9.7.5.2.(2) CNB 9.7.5.2. 2) CNB A-9.7.5.2. 2) |
ASTM | F628-12e2 | Standard Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe With a Cellular Core | NPC 2.2.5.11.(1) NPC 2.2.5.9.(1) NPC A-2.2.5. to 2.2.8. CNP 2.2.5.11. 1) CNP 2.2.5.9. 1) CNP A-2.2.5. à 2.2.8. |
ASTM | F714-13 | Standard Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on Outside Diameter | NPC 2.2.5.5.(1) NPC A-2.2.5. to 2.2.8. CNP 2.2.5.5. 1) CNP A-2.2.5. à 2.2.8. |
ASTM | G115-10 | Standard Guide for Measuring and Reporting Friction Coefficients | NBC 4.1.8.18.(18) CNB 4.1.8.18. 18) |
AWS | ANSI/AWS A5.8M/A5.8: |
Specification for Filler Metals for Brazing and Braze Welding | NPC 2.2.9.2.(4) CNP 2.2.9.2. 4) |
AWWA | ANSI/AWWA C104/A21.4-13 | Cement-Mortar Lining for Ductile-Iron Pipe and Fittings | NPC 2.2.6.4.(2) CNP 2.2.6.4. 2) |
AWWA | ANSI/AWWA C110/A21.10-12 | Ductile-Iron and Gray-Iron Fittings | NPC 2.2.6.4.(3) CNP 2.2.6.4. 3) |
AWWA | ANSI/AWWA C111/A21.11-12 | Rubber-Gasket Joints for Ductile-Iron Pressure Pipe and Fittings | NPC 2.2.6.4.(4) CNP 2.2.6.4. 4) |
AWWA | ANSI/AWWA C151/A21.51-09 | Ductile-Iron Pipe, Centrifugally Cast | NPC 2.2.6.4.(1) NPC A-2.2.5. to 2.2.8. CNP 2.2.6.4. 1) CNP A-2.2.5. à 2.2.8. |
AWWA | ANSI/AWWA C228-08 | Stainless-Steel Pipe Flanges for Water Service – Sizes 2 in. through 72 in. (50 mm through 1,800 mm) | NPC 2.2.6.12.(1) CNP 2.2.6.12. 1) |
AWWA | M14-2004 | Recommended Practice for Backflow Prevention and Cross-Connection Control | NPC A-2.6.2.4.(2) CNP A-2.6.2.4. 2) |
BC Hydro | 2014 | Building Envelope Thermal Bridging Guide | NECB A-3.1.1.5.(5)(a) CNÉB A-3.1.1.5. 5)a) |
BNQ | BNQ 3624-115/2016 | Polyethylene (PE) Pipe and Fittings for Soil and Foundation Drainage | NBC 9.14.3.1.(1) NBC Table 5.9.1.1. |
BNQ | BNQ 3624-115/2016 | Tuyaux et raccords en polyéthylène (PE) pour le drainage des sols et des fondations | CNB 9.14.3.1. 1) CNB Tableau 5.9.1.1. |
CCCBPI | CNRC 30620 | Code national du bâtiment – Canada 1990 | CNPI A-2.1.2.1. 1) |
CCCBPI | CNRC 30630 | Supplément du Code national du bâtiment du Canada 1990 | CNB D-7.2. CNB D-7.3. |
CCCBPI | CNRC 35952 | Lignes directrices pour l'application aux bâtiments existants de la partie 3 du Code national du bâtiment du Canada | CNB A-1.1.1.1. 1) de la division A |
CCCBPI | CNRC 38730F | Code modèle national de l'énergie pour les habitations – Canada 1997 | CNB A-9.36.3.10. 1) CNB A-9.36.4.2. 1) |
CCCBPI | CNRC 38732F | Code national de construction des bâtiments agricoles – Canada 1995 | CNB 1.1.1.1. 3) de la division A CNB A-5.1.2.1. 1) |
CCCBPI | CNRC 40383F | Guide de l'utilisateur – CNB 1995, Protection contre l'incendie, sécurité des occupants et accessibilité (Partie 3) | CNB A-1.1.1.1. 1) de la division A CNPI 7.1.1.2. 2) CNPI 7.2.3.1. 1) CNPI 7.2.3.3. 1) CNPI 7.3.10.1. 1) CNPI 7.3.11.1. 1) CNPI 7.3.12.1. 1) CNPI 7.3.13.1. 1) CNPI 7.3.14.1. 1) CNPI 7.3.15.1. 1) CNPI 7.3.2.1. 1) CNPI 7.3.3.1. 1) CNPI 7.3.4.1. 1) CNPI 7.3.5.1. 1) CNPI 7.3.6.1. 1) CNPI 7.3.7.1. 1) CNPI 7.3.8.1. 1) CNPI 7.3.9.1. 1) |
CCCBPI | CNRC 43963F | Guide de l'utilisateur – CNB 1995, Application de la partie 9 aux bâtiments existants | CNB A-1.1.1.1. 1) de la division A |
CCCBPI | CNRC 47666F | Code national du bâtiment – Canada 2005 | CNPI A-2.1.3.1. 1) |
CCCBPI | CNRC 56190F | Code national du bâtiment – Canada 2015 | CNB A-4.1.8.4. 3) CNB C |
CCBFC | NRCC 30619 | National Building Code of Canada 1990 | NFC A-2.1.2.1.(1) |
CCBFC | NRCC 30629 | Supplement to the National Building Code of Canada 1990 | NBC D-7.2. NBC D-7.3. |
CCBFC | NRCC 35951 | Guidelines for Application of Part 3 of the National Building Code of Canada to Existing Buildings | NBC A-1.1.1.1.(1) of Division A |
CCBFC | NRCC 38730 | Model National Energy Code of Canada for Houses 1997 | NBC A-9.36.3.10.(1) NBC A-9.36.4.2.(2) |
CCBFC | NRCC 38732 | National Farm Building Code of Canada 1995 | NBC 1.1.1.1.(3) of Division A NBC A-5.1.2.1.(1) |
CCBFC | NRCC 40383 | User's Guide – NBC 1995, Fire Protection, Occupant Safety and Accessibility (Part 3) | NBC A-1.1.1.1.(1) of Division A NFC 7.1.1.2.(2) NFC 7.2.3.1.(1) NFC 7.2.3.3.(1) NFC 7.3.10.1.(1) NFC 7.3.11.1.(1) NFC 7.3.12.1.(1) NFC 7.3.13.1.(1) NFC 7.3.14.1.(1) NFC 7.3.15.1.(1) NFC 7.3.2.1.(1) NFC 7.3.3.1.(1) NFC 7.3.4.1.(1) NFC 7.3.5.1.(1) NFC 7.3.6.1.(1) NFC 7.3.7.1.(1) NFC 7.3.8.1.(1) NFC 7.3.9.1.(1) |
CCBFC | NRCC 43963 | User's Guide – NBC 1995, Application of Part 9 to Existing Buildings | NBC A-1.1.1.1.(1) of Division A |
CCBFC | NRCC 47666 | National Building Code of Canada 2005 | NFC A-2.1.3.1.(1) |
CCBFC | NRCC 56190 | National Building Code of Canada 2015 | NBC A-4.1.8.4.(3) NBC C |
CCBFC | NRCC-CONST-56435E | National Building Code of Canada 2020 | NFC 1.3.3.2.(1) of Division A NFC 1.4.1.2.(1) of Division A NFC 2.1.2.1.(1) NFC 2.1.3.1.(1) NFC 2.1.3.2.(1) NFC 2.1.3.3.(1) NFC 2.1.3.4.(1) NFC 2.1.3.7.(1) NFC 2.10.1.1.(1) NFC 2.11.1.1.(1) NFC 2.13.2.1.(1) NFC 2.14.3.1.(1) NFC 2.14.3.2.(1) NFC 2.14.3.2.(2) NFC 2.2.1.1.(1) NFC 2.2.1.1.(2) NFC 2.2.1.1.(3) NFC 2.2.2.1.(1) NFC 2.2.2.1.(2) NFC 2.2.2.4.(2) NFC 2.2.3.1.(1) NFC 2.3.1.1.(1) NFC 2.3.1.2.(1) of Division C NFC 2.3.1.4.(1) NFC 2.4.1.2.(1) NFC 2.5.1.1.(1) NFC 2.6.1.1.(1) NFC 2.6.1.5.(1) NFC 2.6.1.9.(1) NFC 2.6.2.1.(1) NFC 2.7.1.1.(1) NFC 2.7.1.2.(1) NFC 2.7.1.4.(2) NFC 2.7.3.1.(1) NFC 2.8.1.1.(1) NFC 2.8.2.12.(2) NFC 2.8.2.2.(1) NFC 2.8.3.1.(1) NFC 2.8.3.2.(1) NFC 2.9.1.1.(1) NFC 2.9.3.6.(1) NFC 3.1.4.1.(1) NFC 3.2.4.2.(1) NFC 3.2.6.2.(1) NFC 3.2.7.12.(3) NFC 3.2.7.5.(6) NFC 3.2.7.5.(7) NFC 3.2.7.8.(1) NFC 3.2.8.2.(1) NFC 3.2.8.3.(1) NFC 3.2.9.2.(1) NFC 3.2.9.2.(2) NFC 3.2.9.2.(3) NFC 3.2.9.2.(4) NFC 3.2.9.2.(5) NFC 3.3.2.5.(1) NFC 4.1.7.1.(1) NFC 4.2.11.3.(1) NFC 4.2.12.1.(1) NFC 4.2.4.3.(2) NFC 4.2.7.5.(2) NFC 4.2.9.5.(1) NFC 4.3.2.4.(2) NFC 4.3.3.2.(1) NFC 4.5.6.10.(2) NFC 4.5.8.2.(3) NFC 4.6.3.3.(2) NFC 4.6.3.3.(3) NFC 4.9.3.2.(1) NFC 5.1.3.1.(1) NFC 5.3.3.4.(1) NFC 5.5.2.2.(1) NFC 5.5.4.1.(1) NFC 5.5.4.2.(1) NFC 5.5.4.3.(1) NFC 5.5.4.4.(1) NFC 5.6.1.20.(1) NFC 5.6.1.6.(1) NFC 5.6.1.6.(2) NFC 5.6.1.8.(2) NFC 5.6.3.1.(1) NFC 5.6.3.4.(2) NFC 5.6.3.5.(1) NFC 5.6.3.7.(1) NFC 5.6.3.7.(3) NFC 5.6.3.8. NFC 5.6.4.1.(1) NFC 5.6.4.3.(1) NFC 5.6.4.3.(3) NFC 7.1.1.1.(1) NFC 7.1.1.2.(1) NFC 7.1.1.2.(2) NFC 7.1.1.4.(2) NFC A-1.1.1.1.(1) of Division A NFC A-1.4.1.2.(1) of Division A NFC A-2.1.3.1.(1) NFC A-2.1.3.4.(1) NFC A-2.2.1.1.(1) of Division A NFC A-2.7.1.3.(1) NFC A-2.7.1.4.(2) NFC A-2.7.3.1.(1) NFC A-2.8.1.2.(2) NFC A-2.9.3.5.(1) NFC A-3.2.1.1.(1) of Division A NFC A-3.2.2.3.(5) NFC A-3.2.7.12.(3) NFC A-3.2.7.9.(1) NFC A-3.2.9.2.(5) NFC A-4.1.7.1.(1) NFC A-4.2.7.5.(2) NFC A-5.6.1.2.(1) NFC A-5.6.1.4.(4) NFC A-5.6.1.6. NFC A-5.6.1.8. NFC A-6.1.1.2.(1) NPC 1.1.1.1.(3) of Division A NPC 1.4.1.2.(1) of Division A NPC 2.1.3.1.(1) NPC 2.1.4.1.(1) NPC 2.2.5.11.(2) NPC 2.2.5.11.(3) NPC 2.2.6.7.(3) NPC 2.4.10.4.(1) NPC 2.4.3.1.(1) NPC A-2.2.1.1.(1) of Division A NPC A-2.2.5. to 2.2.8. NPC A-2.4.10. NPC A-2.4.10.4.(1) NPC A-3.2.1.1.(1) of Division A NECB 1.1.1.1.(1) of Division A NECB 1.1.1.3.(1) of Division A NECB 1.1.1.3.(2) of Division A NECB 1.4.1.2.(1) of Division A NECB 3.1.1.5.(1) NECB 5.2.1.1.(1) NECB 5.2.2.1.(1) NECB 5.2.2.8.(2) NECB 5.2.5.1.(1) NECB A-3.2.1.1.(1) of Division A NECB A-3.2.3.1.(3) NECB A-5.2.10.4.(1) NECB A-5.2.10.4.(5) NECB A-5.2.2.8.(2) NECB A-5.2.8.4.(1) |
CCCBPI | NRCC-CONST-56435F | Code national du bâtiment – Canada 2020 | CNPI 1.3.3.2. 1) de la division A CNPI 1.4.1.2. 1) de la division A CNPI 2.1.2.1. 1) CNPI 2.1.3.1. 1) CNPI 2.1.3.2. 1) CNPI 2.1.3.3. 1) CNPI 2.1.3.4. 1) CNPI 2.1.3.7. 1) CNPI 2.10.1.1. 1) CNPI 2.11.1.1. 1) CNPI 2.13.2.1. 1) CNPI 2.14.3.1. 1) CNPI 2.14.3.2. 1) CNPI 2.14.3.2. 2) CNPI 2.2.1.1. 1) CNPI 2.2.1.1. 2) CNPI 2.2.1.1. 3) CNPI 2.2.2.1. 1) CNPI 2.2.2.1. 2) CNPI 2.2.2.4. 2) CNPI 2.2.3.1. 1) CNPI 2.3.1.1. 1) CNPI 2.3.1.2. 1) de la division C CNPI 2.3.1.4. 1) CNPI 2.4.1.2. 1) CNPI 2.5.1.1. 1) CNPI 2.6.1.1. 1) CNPI 2.6.1.5. 1) CNPI 2.6.1.9. 1) CNPI 2.6.2.1. 1) CNPI 2.7.1.1. 1) CNPI 2.7.1.2. 1) CNPI 2.7.1.4. 2) CNPI 2.7.3.1. 1) CNPI 2.8.1.1. 1) CNPI 2.8.2.12. 2) CNPI 2.8.2.2. 1) CNPI 2.8.3.1. 1) CNPI 2.8.3.2. 1) CNPI 2.9.1.1. 1) CNPI 2.9.3.6. 1) CNPI 3.1.4.1. 1) CNPI 3.2.4.2. 1) CNPI 3.2.6.2. 1) CNPI 3.2.7.12. 3) CNPI 3.2.7.5. 6) CNPI 3.2.7.5. 7) CNPI 3.2.7.8. 1) CNPI 3.2.8.2. 1) CNPI 3.2.8.3. 1) CNPI 3.2.9.2. 1) CNPI 3.2.9.2. 2) CNPI 3.2.9.2. 3) CNPI 3.2.9.2. 4) CNPI 3.2.9.2. 5) CNPI 3.3.2.5. 1) CNPI 4.1.7.1. 1) CNPI 4.2.11.3. 1) CNPI 4.2.12.1. 1) CNPI 4.2.4.3. 2) CNPI 4.2.7.5. 2) CNPI 4.2.9.5. 1) CNPI 4.3.2.4. 2) CNPI 4.3.3.2. 1) CNPI 4.5.6.10. 2) CNPI 4.5.8.2. 3) CNPI 4.6.3.3. 2) CNPI 4.6.3.3. 3) CNPI 4.9.3.2. 1) CNPI 5.1.3.1. 1) CNPI 5.3.3.4. 1) CNPI 5.5.2.2. 1) CNPI 5.5.4.1. 1) CNPI 5.5.4.2. 1) CNPI 5.5.4.3. 1) CNPI 5.5.4.4. 1) CNPI 5.6.1.20. 1) CNPI 5.6.1.6. 1) CNPI 5.6.1.6. 2) CNPI 5.6.1.8. 2) CNPI 5.6.3.1. 1) CNPI 5.6.3.4. 2) CNPI 5.6.3.5. 1) CNPI 5.6.3.7. 1) CNPI 5.6.3.7. 3) CNPI 5.6.3.8. CNPI 5.6.4.1. 1) CNPI 5.6.4.2. 1) CNPI 5.6.4.2. 3) CNPI 7.1.1.1. 1) CNPI 7.1.1.2. 1) CNPI 7.1.1.2. 2) CNPI 7.1.1.4. 2) CNPI A-1.1.1.1. 1) de la division A CNPI A-1.4.1.2. 1) de la division A CNPI A-2.1.3.1. 1) CNPI A-2.1.3.4. 1) CNPI A-2.2.1.1. 1) de la division A CNPI A-2.7.1.3. 1) CNPI A-2.7.1.4. 2) CNPI A-2.7.3.1. 1) CNPI A-2.8.1.2. 2) CNPI A-2.9.3.5. 1) CNPI A-3.2.1.1. 1) de la division A CNPI A-3.2.2.3. 5) CNPI A-3.2.7.12. 3) CNPI A-3.2.7.9. 1) CNPI A-3.2.9.2. 5) CNPI A-4.1.7.1. 1) CNPI A-4.2.7.5. 2) CNPI A-5.6.1.2. 1) CNPI A-5.6.1.4. 4) CNPI A-5.6.1.6. CNPI A-5.6.1.8. CNPI A-6.1.1.2. 1) CNP 1.1.1.1. 3) de la division A CNP 1.4.1.2. 1) de la division A CNP 2.1.3.1. 1) CNP 2.1.4.1. 1) CNP 2.2.5.11. 2) CNP 2.2.5.11. 3) CNP 2.2.6.7. 3) CNP 2.4.10.4. 1) CNP 2.4.3.1. 1) CNP A-2.2.1.1. 1) de la division A CNP A-2.2.5. à 2.2.8. CNP A-2.4.10. CNP A-2.4.10.4. 1) CNP A-3.2.1.1. 1) de la division A CNÉB 1.1.1.1. 1) de la division A CNÉB 1.1.1.3. 1) de la division A CNÉB 1.1.1.3. 2) de la division A CNÉB 1.4.1.2. 1) de la division A CNÉB 3.1.1.5. 1) CNÉB 5.2.1.1. 1) CNÉB 5.2.2.1. 1) CNÉB 5.2.2.8. 2) CNÉB 5.2.5.1. 1) CNÉB A-3.2.1.1. 1) de la division A CNÉB A-3.2.3.1. 3) CNÉB A-5.2.10.4. 1) CNÉB A-5.2.10.4. 5) CNÉB A-5.2.2.8. 2) CNÉB A-5.2.8.4. 1) |
CCBFC | NRCC-CONST-56436E | National Plumbing Code of Canada 2020 | NBC 2.1.1.2.(4) of Division A NBC 5.6.2.2.(2) NBC 6.3.2.15.(10) NBC 6.3.2.15.(8) NBC 6.3.2.16.(6) NBC 7.1.2.1.(1) NBC 9.31.6.2.(1) NBC 9.36.3.11.(2) NBC 9.36.4.3.(2) NBC A-2.2.1.1.(1) of Division A NBC A-3.2.1.1.(1) of Division A NBC A-4.1.6.4.(3) NBC A-9.36.5.8.(5) NBC C NFC A-2.2.1.1.(1) of Division A NFC A-3.2.1.1.(1) of Division A NFC A-4.1.6.2.(2) NECB 6.2.1.1.(1) NECB A-3.2.1.1.(1) of Division A NECB A-5.2.10.4.(1) NECB A-6.2.6.1.(1) NECB A-8.4.4.20.(6) NECB A-8.4.4.20.(7) |
CCCBPI | NRCC-CONST-56436F | Code national de la plomberie – Canada 2020 | CNB 2.1.1.2. 4) de la division A CNB 5.6.2.2. 2) CNB 6.3.2.15. 10) CNB 6.3.2.15. 8) CNB 6.3.2.16. 6) CNB 7.1.2.1. 1) CNB 9.31.6.2. 1) CNB 9.36.3.11. 2) CNB 9.36.4.3. 2) CNB A-2.2.1.1. 1) de la division A CNB A-3.2.1.1. 1) de la division A CNB A-4.1.6.4. 3) CNB A-9.36.5.8. 5) CNB C CNPI A-2.2.1.1. 1) de la division A CNPI A-3.2.1.1. 1) de la division A CNPI A-4.1.6.2. 2) CNÉB 6.2.1.1. 1) CNÉB A-3.2.1.1. 1) de la division A CNÉB A-5.2.10.4. 1) CNÉB A-6.2.6.1. 1) CNÉB A-8.4.4.20. 7) CNÉB A-8.4.4.20. 6) |
CCBFC | NRCC-CONST-56437E | National Fire Code of Canada 2020 | NBC 1.1.4.1.(1) NBC 1.4.1.2.(1) of Division A NBC 2.1.1.2.(4) of Division A NBC 2.2.4.3.(1) NBC 2.2.6.11.(1) NBC 2.2.8.1.(1) NBC 2.2.8.1.(4) NBC 2.2.8.7.(1) NBC 2.4.2.3.(4) NBC 3.1.13.1.(1) NBC 3.2.3.21.(1) NBC 3.2.5.16.(1) NBC 3.3.1.10.(1) NBC 3.3.1.2.(1) NBC 3.3.2.16.(1) NBC 3.3.2.3.(1) NBC 3.3.4.3.(4) NBC 3.3.5.2.(1) NBC 3.3.6.1.(1) NBC 3.3.6.3.(1) NBC 3.3.6.3.(2) NBC 3.3.6.4.(1) NBC 3.3.6.4.(2) NBC 3.3.6.6.(1) NBC 3.7.3.1.(1) NBC 6.3.4.2.(3) NBC 6.3.4.3.(1) NBC 6.3.4.4.(1) NBC 6.9.1.2.(1) NBC 8.1.1.1.(3) NBC 8.1.1.3.(1) NBC 9.10.20.4.(1) NBC 9.10.21.8.(1) NBC A-1.1.1.1.(1) of Division A NBC A-2.2.1.1.(1) of Division A NBC A-2.2.8.4.(1) NBC A-3.1.2.3.(1) NBC A-3.2.1.1.(1) of Division A NBC A-3.2.4.6.(2) NBC A-3.2.6. NBC A-3.2.7.8.(3) NBC A-3.3. NBC A-3.3.1.7.(1) NBC A-3.3.3.1.(1) NBC A-3.3.6.1.(1) NBC A-3.9.3.1.(1) NBC A-9.10.2.2. NPC 2.5.5.2. NPC A-2.2.1.1.(1) of Division A NPC A-3.2.1.1.(1) of Division A NECB 1.4.1.2.(1) of Division A NECB A-3.2.1.1.(1) of Division A |
CCCBPI | NRCC-CONST-56437F | Code national de prévention des incendies – Canada 2020 | CNB 1.1.4.1. 1) CNB 1.4.1.2. 1) de la division A CNB 2.1.1.2. 4) de la division A CNB 2.2.4.3. 1) CNB 2.2.6.11. 1) CNB 2.2.8.1. 1) CNB 2.2.8.1. 4) CNB 2.2.8.7. 1) CNB 2.4.2.3. 4) CNB 3.1.13.1. 1) CNB 3.2.3.21. 1) CNB 3.2.5.16. 1) CNB 3.3.1.10. 1) CNB 3.3.1.2. 1) CNB 3.3.2.16. 1) CNB 3.3.2.3. 1) CNB 3.3.4.3. 4) CNB 3.3.5.2. 1) CNB 3.3.6.1. 1) CNB 3.3.6.3. 1) CNB 3.3.6.3. 2) CNB 3.3.6.4. 1) CNB 3.3.6.4. 2) CNB 3.3.6.6. 1) CNB 3.7.3.1. 1) CNB 6.3.4.2. 3) CNB 6.3.4.3. 1) CNB 6.3.4.4. 1) CNB 6.9.1.2. 1) CNB 8.1.1.1. 3) CNB 8.1.1.3. 1) CNB 9.10.20.4. 1) CNB 9.10.21.8. 1) CNB A-1.1.1.1. 1) de la division A CNB A-2.2.1.1. 1) de la division A CNB A-2.2.8.4. 1) CNB A-3.1.2.3. 1) CNB A-3.2.1.1. 1) de la division A CNB A-3.2.4.6. 2) CNB A-3.2.6. CNB A-3.2.7.8. 3) CNB A-3.3. CNB A-3.3.1.7. 1) CNB A-3.3.3.1. 1) CNB A-3.3.6.1. 1) CNB A-3.9.3.1. 1) CNB A-9.10.2.2. CNP 2.5.5.2. CNP A-2.2.1.1. 1) de la division A CNP A-3.2.1.1. 1) de la division A CNÉB 1.4.1.2. 1) de la division A CNÉB A-3.2.1.1. 1) de la division A |
CCBFC | NRCC-CONST-56438E | National Energy Code of Canada for Buildings 2020 | NBC 9.36.1.3.(1) NBC 9.36.1.3.(5) NBC 9.36.3.1.(2) NBC 9.36.4.1.(2) NBC 9.36.8.10.(2) NBC 9.36.8.9.(2) NBC A-2.1.1.2.(6) of Division A NBC A-2.2.1.1.(1) of Division A NBC A-2.2.8.1.(1) of Division C NBC A-3.2.1.1.(1) of Division A NBC A-5.4.1. NBC A-9.36.1.3. NBC A-9.36.2.4.(1) NBC A-9.36.3.10.(1) NBC A-9.36.4.2.(2) NBC A-9.36.5.2. NBC Table 9.36.3.10. NFC A-2.2.1.1.(1) of Division A NFC A-3.2.1.1.(1) of Division A NPC A-2.2.1.1.(1) of Division A NPC A-3.2.1.1.(1) of Division A |
CCCBPI | NRCC-CONST-56438F | Code national de l'énergie pour les bâtiments – Canada 2020 | CNB 9.36.1.3. 1) CNB 9.36.1.3. 5) CNB 9.36.3.1. 2) CNB 9.36.4.1. 2) CNB 9.36.8.10. 2) CNB 9.36.8.9. 2) CNB A-2.1.1.2. 6) de la division A CNB A-2.2.1.1. 1) de la division A CNB A-2.2.8.1. 1) de la division C CNB A-3.2.1.1. 1) de la division A CNB A-5.4.1. CNB A-9.36.1.3. CNB A-9.36.2.4. 1) CNB A-9.36.3.10. 1) CNB A-9.36.4.2. 1) CNB A-9.36.5.2. CNB Tableau 9.36.3.10. CNPI A-2.2.1.1. 1) de la division A CNPI A-3.2.1.1. 1) de la division A CNP A-2.2.1.1. 1) de la division A CNP A-3.2.1.1. 1) de la division A |
CCBFC | NRCC-CONST-56529E | Structural Commentaries (User's Guide – NBC 2020: Part 4 of Division B) | NBC A-1.1.1.1.(1) of Division A NBC A-2.3.1.1.(1) NBC A-2.3.4. NBC A-2.3.4.1.(1)(b) NBC A-4.1.1.3.(1) NBC A-4.1.1.3.(2) NBC A-4.1.2.1. NBC A-4.1.2.1.(1) NBC A-4.1.3. NBC A-4.1.3.2.(2) NBC A-4.1.3.2.(4) NBC A-4.1.3.2.(5) NBC A-4.1.3.3.(2) NBC A-4.1.3.4.(1) NBC A-4.1.3.5.(1) NBC A-4.1.3.5.(3) NBC A-4.1.3.6.(1) NBC A-4.1.3.6.(2) NBC A-4.1.3.6.(3) NBC A-4.1.3.6.(4) NBC A-4.1.5.17. NBC A-4.1.5.5. NBC A-4.1.5.8. NBC A-4.1.6.1.(1) NBC A-4.1.6.16. NBC A-4.1.6.2. NBC A-4.1.6.3.(2) NBC A-4.1.6.4.(1) NBC A-4.1.7.13. NBC A-4.1.7.2.(2) NBC A-4.1.7.3.(10) NBC A-4.1.7.3.(5)(c) NBC A-4.1.7.7.(2) NBC A-4.1.7.9.(1) NBC A-4.1.8.10.(10)(a) NBC A-4.1.8.10.(5) and (6) NBC A-4.1.8.10.(7) NBC A-4.1.8.10.(9) NBC A-4.1.8.11.(3) NBC A-4.1.8.12.(1)(a) NBC A-4.1.8.12.(1)(b) NBC A-4.1.8.12.(3) NBC A-4.1.8.12.(4)(a) NBC A-4.1.8.13.(4) NBC A-4.1.8.15.(1) NBC A-4.1.8.15.(3) NBC A-4.1.8.15.(4) NBC A-4.1.8.15.(5) NBC A-4.1.8.15.(6) NBC A-4.1.8.15.(7) NBC A-4.1.8.15.(8) NBC A-4.1.8.16.(1) NBC A-4.1.8.16.(10) NBC A-4.1.8.16.(4) NBC A-4.1.8.16.(6)(a) NBC A-4.1.8.16.(7) NBC A-4.1.8.16.(8)(a) NBC A-4.1.8.17.(1) NBC A-4.1.8.18. NBC A-4.1.8.18.(13) and 4.4.3.1.(1) NBC A-4.1.8.18.(14) and (15) NBC A-4.1.8.18.(16) NBC A-4.1.8.18.(7)(e) NBC A-4.1.8.19.(3)(a) NBC A-4.1.8.19.(4) and 4.1.8.21.(5) NBC A-4.1.8.2.(1) NBC A-4.1.8.21.(4)(a) NBC A-4.1.8.3.(4) NBC A-4.1.8.3.(6) NBC A-4.1.8.3.(7)(b) and (c) NBC A-4.1.8.3.(8) NBC A-4.1.8.4.(2) and (3) NBC A-4.1.8.4.(3) NBC A-4.1.8.7.(1) NBC A-4.1.8.9.(4) NBC A-4.1.8.9.(5) NBC A-4.2.4.1.(3) NBC A-4.2.4.1.(5) NBC A-4.2.5.1.(1) NBC A-4.2.6.1.(1) NBC A-4.2.7.2.(1) NBC A-4.3.6.1.(1) NBC A-4.4.2.1.(1) NBC A-5.1.4.2. NBC A-5.2.2.2.(4) NBC A-Table 4.1.2.1. NBC A-Table 4.1.3.4. NBC A-Table 4.1.8.5.-A NBC A-Table 4.1.8.6. NBC Table C-3 |
CCCBPI | NRCC-CONST-56529F | Commentaires sur le calcul des structures (Guide de l'utilisateur – CNB 2020 : Partie 4 de la division B) | CNB A-1.1.1.1. 1) de la division A CNB A-2.3.1.1. 1) CNB A-2.3.4. CNB A-2.3.4.1. 1)b) CNB A-4.1.1.3. 1) CNB A-4.1.1.3. 2) CNB A-4.1.2.1. CNB A-4.1.2.1. 1) CNB A-4.1.3. CNB A-4.1.3.2. 2) CNB A-4.1.3.2. 4) CNB A-4.1.3.2. 5) CNB A-4.1.3.3. 2) CNB A-4.1.3.4. 1) CNB A-4.1.3.5. 1) CNB A-4.1.3.5. 3) CNB A-4.1.3.6. 2) CNB A-4.1.3.6. 1) CNB A-4.1.3.6. 3) CNB A-4.1.3.6. 4) CNB A-4.1.5.17. CNB A-4.1.5.5. CNB A-4.1.5.8. CNB A-4.1.6.1. 1) CNB A-4.1.6.16. CNB A-4.1.6.2. CNB A-4.1.6.3. 2) CNB A-4.1.6.4. 1) CNB A-4.1.7.13. CNB A-4.1.7.2. CNB A-4.1.7.3. 10) CNB A-4.1.7.3. 5)c) CNB A-4.1.7.7. 2) CNB A-4.1.7.9. 1) CNB A-4.1.8.10. 10)a) CNB A-4.1.8.10. 5) et 6) CNB A-4.1.8.10. 7) CNB A-4.1.8.10. 9) CNB A-4.1.8.11. 3) CNB A-4.1.8.12. 1)a) CNB A-4.1.8.12. 1)b) CNB A-4.1.8.12. 3) CNB A-4.1.8.12. 4)a) CNB A-4.1.8.13. 4) CNB A-4.1.8.15. 3) CNB A-4.1.8.15. 1) CNB A-4.1.8.15. 4) CNB A-4.1.8.15. 5) CNB A-4.1.8.15. 6) CNB A-4.1.8.15. 7) CNB A-4.1.8.15. 8) CNB A-4.1.8.16. 1) CNB A-4.1.8.16. 4) CNB A-4.1.8.16. 10) CNB A-4.1.8.16. 6)a) CNB A-4.1.8.16. 7) CNB A-4.1.8.16. 8)a) CNB A-4.1.8.17. 1) CNB A-4.1.8.18. CNB A-4.1.8.18. 14) et 15) CNB A-4.1.8.18. 16) CNB A-4.1.8.18. 13) et 4.4.3.1. 1) CNB A-4.1.8.18. 7)e) CNB A-4.1.8.19. 3)a) CNB A-4.1.8.19. 4) et 4.1.8.21. 5) CNB A-4.1.8.2. 1) CNB A-4.1.8.21. 4)a) CNB A-4.1.8.3. 4) CNB A-4.1.8.3. 6) CNB A-4.1.8.3. 7)b) et c) CNB A-4.1.8.3. 8) CNB A-4.1.8.4. 2) et 3) CNB A-4.1.8.4. 3) CNB A-4.1.8.7. 1) CNB A-4.1.8.9. 4) CNB A-4.1.8.9. 5) CNB A-4.2.4.1. 3) CNB A-4.2.4.1. 5) CNB A-4.2.5.1. 1) CNB A-4.2.6.1. 1) CNB A-4.2.7.2. 1) CNB A-4.3.6.1. 1) CNB A-4.4.2.1. 1) CNB A-5.1.4.2. CNB A-5.2.2.2. 4) CNB A-Tableau 4.1.2.1. CNB A-Tableau 4.1.3.4. CNB A-Tableau 4.1.8.5.-A CNB A-Tableau 4.1.8.6. CNB Tableau C-3 |
CCME | PN 1326 (2003) | Environmental Code of Practice for Aboveground and Underground Storage Tank Systems Containing Petroleum and Allied Petroleum Products | NFC A-4.3.16.1.(1) NFC A-4.4.2.1.(3) |
CCME | PN 1327 (2003) | Code de recommandations techniques pour la protection de l'environnement applicable aux systèmes de stockage hors sol et souterrains de produits pétroliers et de produits apparentés | CNPI A-4.3.16.1. 1) CNPI A-4.4.2.1. 3) |
CFA | 1990 | Using the Canadian Fuels Colour-Symbol System to Mark Equipment and Vehicles For Product Identification | NFC 4.3.1.7.(1) NFC 4.5.4.1.(3) NFC 4.5.7.6.(1) |
ACC | 1990 | Système d'encodage par couleurs pour identifier les produits pétroliers contenus dans le matériel ou les véhicules | CNPI 4.3.1.7. 1) CNPI 4.5.4.1. 3) CNPI 4.5.7.6. 1) |
CGA | P-1 (2008) | Standard for Safe Handling of Compressed Gases in Containers | NFC A-3.1.1.4.(1)(a) CNPI A-3.1.1.4. 1)a) |
CGSB | CAN/CGSB-10.3-92 | Air Setting Refractory Mortar | NBC 9.21.3.4.(2) NBC 9.21.3.9.(1) NBC 9.22.2.2.(2) |
ONGC | CAN/CGSB-10.3-92 | Mortier réfractaire durcissant à l'air | CNB 9.21.3.4. 2) CNB 9.21.3.9. 1) CNB 9.22.2.2. 2) |
CGSB | CAN/CGSB-11.3-M87 | Hardboard | NBC 9.29.7.1.(1) NBC 9.30.2.2.(1) NBC Table 5.9.1.1. |
ONGC | CAN/CGSB-11.3-M87 | Panneaux de fibres durs | CNB 9.29.7.1. 1) CNB 9.30.2.2. 1) CNB Tableau 5.9.1.1. |
CGSB | CAN/CGSB-12.10-M76 | Glass, Light and Heat Reflecting | NBC 9.6.1.2.(1) |
ONGC | CAN/CGSB-12.10-M76 | Verre réflecteur de lumière et de chaleur | CNB 9.6.1.2. 1) |
CGSB | CAN/CGSB-12.11-M90 | Wired Safety Glass | NBC 3.3.1.20.(3) NBC 3.4.6.15.(1) NBC 3.4.6.15.(3) NBC 9.6.1.2.(1) NBC 9.6.1.4.(1) NBC 9.8.8.7.(1) |
ONGC | CAN/CGSB-12.11-M90 | Verre de sécurité armé | CNB 3.3.1.20. 3) CNB 3.4.6.15. 1) CNB 3.4.6.15. 3) CNB 9.6.1.2. 1) CNB 9.6.1.4. 1) CNB 9.8.8.7. 1) |
CGSB | CAN/CGSB-12.1-2017 | Safety Glazing | NBC 3.3.1.20.(3) NBC 3.3.2.17.(1) NBC 3.3.2.17.(2) NBC 3.4.6.15.(1) NBC 3.4.6.15.(3) NBC 3.7.2.4.(1) NBC 9.6.1.2.(1) NBC 9.6.1.4.(1) NBC 9.6.1.4.(6) NBC 9.8.8.7.(1) NBC Table 5.9.1.1. |
ONGC | CAN/CGSB-12.1-2017 | Vitrage de sécurité | CNB 3.3.1.20. 3) CNB 3.3.2.17. 1) CNB 3.3.2.17. 2) CNB 3.4.6.15. 1) CNB 3.4.6.15. 3) CNB 3.7.2.4. 1) CNB 9.6.1.2. 1) CNB 9.6.1.4. 1) CNB 9.6.1.4. 6) CNB 9.8.8.7. 1) CNB Tableau 5.9.1.1. |
CGSB | CAN/CGSB-12.2-M91 | Flat, Clear Sheet Glass | NBC 9.6.1.2.(1) NBC Table 5.9.1.1. |
ONGC | CAN/CGSB-12.2-M91 | Verre à vitres plat et clair | CNB 9.6.1.2. 1) CNB Tableau 5.9.1.1. |
CGSB | CAN/CGSB-12.20-M89 | Structural Design of Glass for Buildings | NBC 4.3.6.1.(1) NBC 9.6.1.3.(1) NBC A-9.6.1.3.(2) |
ONGC | CAN/CGSB-12.20-M89 | Règles de calcul du verre à vitre pour le bâtiment | CNB 4.3.6.1. 1) CNB 9.6.1.3. 1) CNB A-9.6.1.3. 2) |
CGSB | CAN/CGSB-12.3-M91 | Flat, Clear Float Glass | NBC 9.6.1.2.(1) NBC Table 5.9.1.1. |
ONGC | CAN/CGSB-12.3-M91 | Verre flotté, plat et clair | CNB 9.6.1.2. 1) CNB Tableau 5.9.1.1. |
CGSB | CAN/CGSB-12.4-M91 | Heat Absorbing Glass | NBC 9.6.1.2.(1) NBC Table 5.9.1.1. |
ONGC | CAN/CGSB-12.4-M91 | Verre athermane | CNB 9.6.1.2. 1) CNB Tableau 5.9.1.1. |
CGSB | CAN/CGSB-12.8-97 | Insulating glass units | NBC 9.6.1.2.(1) NBC Table 5.9.1.1. |
ONGC | CAN/CGSB-12.8-97 | Vitrages isolants | CNB 9.6.1.2. 1) CNB Tableau 5.9.1.1. |
CGSB | CAN/CGSB-12.9-M91 | Spandrel glass | NBC 9.6.1.2.(1) NBC Table 5.9.1.1. |
ONGC | CAN/CGSB-12.9-M91 | Verre de tympan | CNB 9.6.1.2. 1) CNB Tableau 5.9.1.1. |
CGSB | CAN/CGSB-149.10- |
Determination of the airtightness of building envelopes by the fan depressurization method | NBC 9.36.6.3.(1) NBC 9.36.6.3.(2) |
ONGC | CAN/CGSB-149.10- |
Détermination de l'étanchéité à l'air des enveloppes de bâtiment par la méthode de dépressurisation au moyen d'un ventilateur |
CNB 9.36.6.3. 1) CNB 9.36.6.3. 2) |
CGSB | CAN/CGSB-1.501-M89 | Method for Permeance of Coated Wallboard | NBC 5.5.1.2.(2) NBC 9.25.4.2.(7) |
ONGC | CAN/CGSB-1.501-M89 | Méthode de détermination de la perméance des panneaux muraux revêtus | CNB 5.5.1.2. 2) CNB 9.25.4.2. 7) |
CGSB | CAN/CGSB-19.22-M89 | Mildew-Resistant Sealing Compound for Tubs and Tiles | NBC 9.29.10.5.(1) |
ONGC | CAN/CGSB-19.22-M89 | Mastic d'étanchéité, résistant à la moisissure, pour baignoires et carreaux | CNB 9.29.10.5. 1) |
CGSB | CAN/CGSB-37.50-M89 | Hot-Applied, Rubberized Asphalt for Roofing and Waterproofing | NBC 9.13.3.2.(2) NBC Table 5.9.1.1. NBC Table 9.26.2.1.B |
ONGC | CAN/CGSB-37.50-M89 | Bitume caoutchouté, appliqué à chaud, pour le revêtement des toitures et l'imperméabilisation à l'eau | CNB 9.13.3.2. 2) CNB Tableau 5.9.1.1. CNB Tableau 9.26.2.1.B |
CGSB | CAN/CGSB-37.51-M90 | Application for Hot-Applied Rubberized Asphalt for Roofing and Waterproofing | NBC 9.26.15.1.(1) |
ONGC | CAN/CGSB-37.51-M90 | Application à chaud du bitume caoutchouté pour le revêtement des toitures et pour l'imperméabilisation à l'eau | CNB 9.26.15.1. 1) |
CGSB | CAN/CGSB-37.54-95 | Polyvinyl Chloride Roofing and Waterproofing Membrane | NBC 9.13.3.2.(2) NBC Table 5.9.1.1. NBC Table 9.26.2.1.B |
ONGC | CAN/CGSB-37.54-95 | Membrane de poly(chlorure de vinyle) pour le revêtement de toitures et l'imperméabilisation à l'eau | CNB 9.13.3.2. 2) CNB Tableau 5.9.1.1. CNB Tableau 9.26.2.1.B |
CGSB | CAN/CGSB-37.58-M86 | Membrane, Elastomeric, Cold-Applied Liquid, for Non-Exposed Use in Roofing and Waterproofing | NBC 9.13.3.2.(2) NBC Table 5.9.1.1. NBC Table 9.26.2.1.B |
ONGC | CAN/CGSB-37.58-M86 | Membrane d'élastomère obtenue par liquide appliqué à froid, pour l'utilisation protégée dans le revêtement des toitures et l'imperméabilisation | CNB 9.13.3.2. 2) CNB Tableau 5.9.1.1. CNB Tableau 9.26.2.1.B |
CGSB | CAN/CGSB-41.24-95 | Rigid Vinyl Siding, Soffits and Fascia | NBC Table 5.9.1.1. |
ONGC | CAN/CGSB-41.24-95 | Bardages, soffites et bordures de toit en vinyle rigide | CNB Tableau 5.9.1.1. |
CGSB | CAN/CGSB-4.129-93 | Carpet for Commercial Use | NBC D-3.1.1. |
ONGC | CAN/CGSB-4.129-93 | Tapis pour utilisation commerciale | CNB D-3.1.1. |
CGSB | CAN/CGSB-51.25-M87 | Thermal Insulation, Phenolic, Faced | NBC 9.25.2.2.(1) NBC Table 9.23.17.2.A |
ONGC | CAN/CGSB-51.25-M87 | Isolant thermique phénolique, avec revêtement | CNB 9.25.2.2. 1) CNB Tableau 9.23.17.2.A |
CGSB | CAN/CGSB-51.32-M77 | Sheathing, Membrane, Breather Type | NBC 9.20.13.9.(1) NBC 9.27.3.2.(1) NBC Table 5.9.1.1. NBC Table 9.26.2.1.A |
ONGC | CAN/CGSB-51.32-M77 | Membrane de revêtement, perméable à la vapeur d'eau | CNB 9.20.13.9. 1) CNB 9.27.3.2. 1) CNB Tableau 5.9.1.1. CNB Tableau 9.26.2.1.A |
CGSB | CAN/CGSB-51.33-M89 | Vapour Barrier Sheet, Excluding Polyethylene, for Use in Building Construction | NBC 9.25.4.2.(5) NBC A-9.25.4.2.(6) NBC Table 5.9.1.1. |
ONGC | CAN/CGSB-51.33-M89 | Pare-vapeur en feuille, sauf en polyéthylène, pour bâtiments | CNB 9.25.4.2. 5) CNB A-9.25.4.2. 6) CNB Tableau 5.9.1.1. |
CGSB | CAN/CGSB-51.34-M86 | Vapour Barrier, Polyethylene Sheet for Use in Building Construction | NBC 9.13.2.2.(2) NBC 9.18.6.2.(1) NBC 9.25.3.2.(2) NBC 9.25.3.6.(1) NBC 9.25.4.2.(4) NBC Table 5.9.1.1. |
ONGC | CAN/CGSB-51.34-M86 | Pare-vapeur en feuille de polyéthylène pour bâtiments | CNB 9.13.2.2. 2) CNB 9.18.6.2. 1) CNB 9.25.3.2. 2) CNB 9.25.3.6. 1) CNB 9.25.4.2. 4) CNB Tableau 5.9.1.1. |
CGSB | CAN/CGSB-51.71-2005 | Depressurization Test | NBC 9.32.3.8.(7) |
ONGC | CAN/CGSB-51.71-2005 | Essai de dépressurisation | CNB 9.32.3.8. 7) |
CGSB | CAN/CGSB-71.26-M88 | Adhesive for Field-Gluing Plywood to Lumber Framing for Floor Systems | NBC A-9.23.4.2.(2) NBC Table A-9.23.4.2.(2)C |
ONGC | CAN/CGSB-71.26-M88 | Adhésif pour coller sur le chantier des contreplaqués à l'ossature en bois de construction des planchers | CNB A-9.23.4.2. 2) CNB Tableau A-9.23.4.2. 2)C |
CGSB | CAN/CGSB-7.2-94 | Adjustable Steel Columns | NBC 9.17.3.4.(1) NBC A-9.17.3.4. |
ONGC | CAN/CGSB-7.2-94 | Poteaux d'acier réglables | CNB 9.17.3.4. 1) CNB A-9.17.3.4. |
CGSB | CAN/CGSB-82.6-M86 | Doors, Mirrored Glass, Sliding or Folding, Wardrobe | NBC 9.6.1.2.(2) NBC A-9.6.1.2.(2) |
ONGC | CAN/CGSB-82.6-M86 | Portes-miroirs coulissantes ou pliantes pour placards | CNB 9.6.1.2. 2) CNB A-9.6.1.2. 2) |
CGSB | CAN/CGSB-92.2-M90 | Trowel or Spray Applied Acoustical Material | NBC D-2.3.4. |
ONGC | CAN/CGSB-92.2-M90 | Matières acoustiques appliquées à la truelle ou au vaporisateur | CNB D-2.3.4. |
CGSB | CAN/CGSB-93.1-M85 | Sheet, Aluminum Alloy, Prefinished, Residential | NBC 9.27.11.1.(3) NBC A-9.27.11.1.(2) and (3) NBC Table 5.9.1.1. |
ONGC | CAN/CGSB-93.1-M85 | Tôle d'alliage d'aluminium préfinie, pour bâtiments résidentiels | CNB 9.27.11.1. 3) CNB A-9.27.11.1. 2) et 3) CNB Tableau 5.9.1.1. |
CGSB | CAN/CGSB-93.2-M91 | Prefinished Aluminum Siding, Soffits, and Fascia, for Residential Use | NBC 3.2.3.6.(5) NBC 9.10.14.5.(12) NBC 9.10.14.5.(8) NBC 9.10.15.5.(11) NBC 9.10.15.5.(7) NBC 9.27.11.1.(2) NBC A-9.27.11.1.(2) and (3) NBC Table 5.9.1.1. |
ONGC | CAN/CGSB-93.2-M91 | Bardage, soffites et bordures de toit en aluminium préfini pour bâtiments résidentiels | CNB 3.2.3.6. 5) CNB 9.10.14.5. 12) CNB 9.10.14.5. 8) CNB 9.10.15.5. 11) CNB 9.10.15.5. 7) CNB 9.27.11.1. 2) CNB A-9.27.11.1. 2) et 3) CNB Tableau 5.9.1.1. |
ONGC | CAN2-4.162-FM80 (anciennement CAN/CGSB-4.162-M80) | Textiles utilisés dans les hôpitaux – Exigences de résistance à l'inflammabilité | CNPI 2.3.2.3. 1) |
CGSB | CAN2-4.162-M80 (formerly CAN/CGSB-4.162-M80) | Hospital Textiles – Flammability Performance Requirements | NFC 2.3.2.3.(1) |
CGSB | 37-GP-55M-1979 | Application of Sheet Applied Flexible Polyvinyl Chloride Roofing Membrane | NBC 9.26.16.1.(1) |
ONGC | 37-GP-55M-1979 | Application de la membrane en feuilles souples de poly(chlorure de vinyle) pour le revêtement des toitures | CNB 9.26.16.1. 1) |
CGSB | 37-GP-56M-1985 | Membrane, Modified, Bituminous, Prefabricated, and Reinforced for Roofing | NBC 9.13.3.2.(2) NBC Table 9.26.2.1.B |
ONGC | 37-GP-56M-1985 | Membrane bitumineuse modifiée, préfabriquée et renforcée, pour le revêtement des toitures | CNB 9.13.3.2. 2) CNB Tableau 9.26.2.1.B |
CGSB | 37-GP-9Ma-1983 | Primer, Asphalt, Unfilled, for Asphalt Roofing, Dampproofing and Waterproofing | NBC 9.13.3.2.(2) NBC Table 5.9.1.1. NBC Table 9.26.2.1.A |
ONGC | 37-GP-9Ma-1983 | Bitume non fillerisé pour couche de base des revêtements de toitures et pour l'imperméabilisation à l'humidité et à l'eau | CNB 9.13.3.2. 2) CNB Tableau 5.9.1.1. CNB Tableau 9.26.2.1.A |
CGSB | 4-GP-36M-1978 | Carpet Underlay, Fiber Type | NBC D-3.1.1. |
ONGC | 4-GP-36M-1978 | Thibaude, type fibre | CNB D-3.1.1. |
CGSB | 51-GP-27M-1979 | Thermal Insulation, Polystyrene, Loose Fill | NBC 9.25.2.2.(1) |
ONGC | 51-GP-27M-1979 | Isolant thermique, polystyrène, à bourrage lâche | CNB 9.25.2.2. 1) |
CISC | 2018 | Crane-Supporting Steel Structures: Design Guide (Third Edition) | NBC A-4.1.3.2.(2) CNB A-4.1.3.2. 2) |
CMHC | 1988 | Air Permeance of Building Materials | NBC Table A-9.25.5.1.(1) |
SCHL | 1988 | Perméance des matériaux de construction à l'air | CNB Tableau A-9.25.5.1. 1) |
CMHC | 1993 | Testing of Fresh Air Mixing Devices | NBC A-9.32.3.4. |
SCHL | 1993 | Essais de mélangeurs d'air frais | CNB A-9.32.3.4. |
CCSN | L.C. 1997, ch. 9 | Loi sur la sûreté et la réglementation nucléaires | CNPI 3.1.1.2. 1) |
CNSC | S.C. 1997, c. 9 | Nuclear Safety and Control Act | NFC 3.1.1.2.(1) |
CSA | AAMA/WDMA/CSA 101/I.S.2/A440 |
North American Fenestration Standard/Specification for windows, doors, and skylights | NBC 5.9.2.2.(1) NBC 9.36.2.9.(3) NBC 9.7.4.1.(1) NBC 9.7.4.2.(1) NBC 9.7.5.1.(1) NBC 9.7.5.3.(1) NBC A-5.3.1.2. NBC A-5.9.2.3.(1) NBC A-5.9.3.1.(1) NBC A-9.7.4.2.(1) NBC Table 9.7.3.3. NECB 3.2.4.3.(4) NECB 3.2.4.3.(5) |
CSA | AAMA/WDMA/CSA 101/I.S.2/A440 |
Norme nord-américaine sur les fenêtres/Spécification relative aux fenêtres, aux portes et aux lanterneaux | CNB 5.9.2.2. 1) CNB 9.36.2.9. 3) CNB 9.7.4.1. 1) CNB 9.7.4.2. 1) CNB 9.7.5.1. 1) CNB 9.7.5.3. 1) CNB A-5.3.1.2. CNB A-5.9.2.3. 1) CNB A-5.9.3.1. 1) CNB A-9.7.4.2. 1) CNB Tableau 9.7.3.3. CNÉB 3.2.4.3. 4) CNÉB 3.2.4.3. 5) |
CSA | CSA/ANSI |
Code for digester gas, landfill gas, and biogas generation and utilization | NBC 2.2.8.1.(3) |
CSA | CSA/ANSI |
Code |
CNB 2.2.8.1. 3) |
CSA | A123.17-05 | Asphalt Glass Felt Used in Roofing and Waterproofing | NBC 9.13.3.2.(2) NBC Table 5.9.1.1. NBC Table 9.26.2.1.B CNB 9.13.3.2. 2) CNB Tableau 5.9.1.1. CNB Tableau 9.26.2.1.B |
CSA | A123.22-08 | Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection | NBC Table 9.26.2.1.B CNB Tableau 9.26.2.1.B |
CSA | A123.23-15 | Product specification for polymer-modified bitumen sheet, prefabricated and reinforced | NBC Table 5.9.1.1. NBC Table 9.26.2.1.B |
CSA | A123.23-15 | Spécification de produit pour les feuilles en bitume modifié par polymère, préfabriquées et armées | CNB Tableau 5.9.1.1. CNB Tableau 9.26.2.1.B |
CSA | A123.3-05 | Asphalt Saturated Organic Roofing Felt | NBC Table 5.9.1.1. NBC Table 9.26.2.1.B |
CSA | A123.3-05 | Feutre organique à toiture imprégné à coeur de bitume | CNB Tableau 5.9.1.1. CNB Tableau 9.26.2.1.B |
CSA | A123.51-14 | Asphalt shingle application on roof slopes 1:6 and steeper | NBC 9.26.1.3.(1) NBC Table 5.9.1.1. |
CSA | A123.51-14 | Pose de bardeaux d'asphalte sur des pentes de toit de 1:6 et plus | CNB 9.26.1.3. 1) CNB Tableau 5.9.1.1. |
CSA | A123.5:16 | Asphalt shingles made from glass felt and surfaced with mineral granules | NBC Table 5.9.1.1. NBC Table 9.26.2.1.B |
CSA | A123.5:16 | Bardeaux d'asphalte en feutre de fibres de verre et à surfaçage minéral | CNB Tableau 5.9.1.1. CNB Tableau 9.26.2.1.B |
CSA | A165.1-14 | Concrete block masonry units | NBC 9.15.2.2.(1) NBC 9.17.5.1.(1) NBC 9.20.2.1.(1) NBC 9.20.2.6.(1) NBC D-2.1.1. NBC Table 5.9.1.1. NBC Table A-9.11.1.4.A NBC Table A-9.11.1.4.C |
CSA | A165.1-14 | Éléments de maçonnerie en bloc de béton | CNB 9.15.2.2. 1) CNB 9.17.5.1. 1) CNB 9.20.2.1. 1) CNB 9.20.2.6. 1) CNB D-2.1.1. CNB Tableau 5.9.1.1. CNB Tableau A-9.11.1.4.A CNB Tableau A-9.11.1.4.C |
CSA | A165.2-14 | Concrete Brick Masonry Units | NBC 9.20.2.1.(1) NBC Table 5.9.1.1. |
CSA | A165.2-14 | Briques en béton | CNB 9.20.2.1. 1) CNB Tableau 5.9.1.1. |
CSA | A165.3-14 | Prefaced concrete masonry units | NBC 9.20.2.1.(1) NBC Table 5.9.1.1. |
CSA | A165.3-14 | Éléments de maçonnerie en béton glacés | CNB 9.20.2.1. 1) CNB Tableau 5.9.1.1. |
CSA | A23.1: |
Concrete materials and methods of concrete construction | NBC 2.3.2.5.(5) NBC 4.2.3.6.(1) NBC 4.2.3.9.(1) NBC 9.3.1.1.(1) NBC 9.3.1.1.(4) NBC 9.3.1.3.(1) NBC 9.3.1.4.(1) NBC Table 5.9.1.1. |
CSA | A23.1: |
CNB 2.3.2.5. 5) CNB 4.2.3.6. 1) CNB 4.2.3.9. 1) CNB 9.3.1.1. 1) CNB 9.3.1.1. 4) CNB 9.3.1.3. 1) CNB 9.3.1.4. 1) CNB Tableau 5.9.1.1. |
|
CSA | A23.1: |
Concrete materials and methods of concrete construction/Test methods and standard practices for concrete | NBC D-1.4.3. |
CSA | A23.1: |
CNB D-1.4.3. | |
CSA | A23.3: |
Design of concrete structures | NBC 4.1.8.18.(7) NBC 4.3.3.1.(1) NBC A-4.1.3.2.(4) NBC A-4.1.8.16.(1) NBC A-4.1.8.16.(4) NBC A-4.3.3.1.(1) NBC D-2.1.5. NBC D-2.6.6. NBC D-2.8.2. NBC Table 4.1.8.9. |
CSA | A23.3: |
CNB 4.1.8.18. 7) CNB 4.3.3.1. 1) CNB A-4.1.3.2. 4) CNB A-4.1.8.16. 1) CNB A-4.1.8.16. 4) CNB A-4.3.3.1. 1) CNB D-2.1.5. CNB D-2.6.6. CNB D-2.8.2. CNB Tableau 4.1.8.9. |
|
CSA | A23.4-16 | Precast concrete – Materials and construction | NBC A-4.3.3.1.(1) |
CSA | A23.4-16 | Béton préfabriqué – Constituants et exécution des travaux | CNB A-4.3.3.1. 1) |
CSA | A257.1:19 | Non-reinforced circular concrete culvert, storm drain, sewer pipe, and fittings | NPC 2.2.5.2.(1) NPC A-2.2.5. to 2.2.8. CNP 2.2.5.2. 1) CNP A-2.2.5. à 2.2.8. |
CSA | A257.2:19 | Reinforced circular concrete culvert, storm drain, sewer pipe, and fittings | NPC 2.2.5.2.(1) NPC A-2.2.5. to 2.2.8. CNP 2.2.5.2. 1) CNP A-2.2.5. à 2.2.8. |
CSA | A257.3:19 | Joints for circular concrete sewer and culvert pipe, manhole sections, and fittings using rubber gaskets | NPC 2.2.5.2.(2) CNP 2.2.5.2. 2) |
CSA | A257.4:19 | Precast reinforced circular concrete manhole sections, catch basins, and fittings | NPC 2.2.5.2.(5) CNP 2.2.5.2. 5) |
CSA | A277-16 | Procedure for certification of prefabricated buildings, modules, and panels | NBC A-1.1.1.1.(2) of Division A |
CSA | A277-16 | Mode opératoire visant la certification des bâtiments, des modules et des panneaux préfabriqués | CNB A-1.1.1.1. 2) de la division A |
CSA | A3001 |
Cementitious Materials for Use in Concrete | NBC 9.28.2.1.(1) NBC 9.3.1.2.(1) NBC Table 5.9.1.1. |
CSA | A3001 |
CNB 9.28.2.1. 1) CNB 9.3.1.2. 1) CNB Tableau 5.9.1.1. |
|
CSA | A440S1:19 | Canadian Supplement to AAMA/WDMA/CSA 101/I.S.2/A440-17, North American Fenestration Standard/Specification for windows, doors, and skylights | NBC 5.9.2.2.(1) NBC 5.9.3.5.(3) NBC 9.36.2.9.(3) NBC 9.7.4.2.(1) NBC A-5.9.2.2. NBC A-5.9.3.5.(3) NBC A-9.7.4.2.(1) |
CSA | A440S1:19 | Supplément canadien à AAMA/WDMA/CSA 101/I.S.2/A440-17, Norme nord-américaine sur les fenêtres/Spécification relative aux fenêtres, aux portes et aux lanterneaux | CNB 5.9.2.2. 1) CNB 5.9.3.5. 3) CNB 9.36.2.9. 3) CNB 9.7.4.2. 1) CNB A-5.9.2.2. CNB A-5.9.3.5. 3) CNB A-9.7.4.2. 1) |
CSA | A440.2:19 | Fenestration energy performance | NBC A-5.3.1.2. NBC A-5.9.3.3.(1) NBC A-9.7.4.2.(1) NBC Table 9.36.8.6. |
CSA | A440.2:19 | Rendement énergétique des systèmes de fenêtrage | CNB A-5.3.1.2. CNB A-5.9.3.3. 1) CNB A-9.7.4.2. 1) CNB Tableau 9.36.8.6. |
CSA | A440.2: |
Fenestration energy performance/User |
NBC 9.36.2.2.(3) NBC A-Table 9.36.2.7.-A NBC Table 9.7.3.3. NECB 3.1.1.5.(3) NECB A-3.1.1.6.(1) |
CSA | A440.2: |
Rendement énergétique des systèmes de fenêtrage/Guide d'utilisation de CSA A440.2: |
CNB 9.36.2.2. 3) CNB A-Tableau 9.36.2.7.-A CNB Tableau 9.7.3.3. CNÉB 3.1.1.5. 3) CNÉB A-3.1.1.6. 1) |
CSA | A440.3:19 | User guide to CSA A440.2:19, Fenestration energy performance | NBC A-5.3.1.2. |
CSA | A440.3:19 | Guide d'utilisation de CSA A440.2:19, Rendement énergétique des systèmes de fenêtrage | CNB A-5.3.1.2. |
CSA | A440.4:19 | Window, door, and skylight installation | NBC 9.7.6.1.(1) NBC A-5.9.2.3.(1) NBC A-9.7.4.2.(1) |
CSA | A440.4:19 | Installation des fenêtres, des portes et des lanterneaux | CNB 9.7.6.1. 1) CNB A-5.9.2.3. 1) CNB A-9.7.4.2. 1) |
CSA | A60.1-M1976 | Vitrified Clay Pipe | NPC 2.2.5.3.(1) NPC A-2.2.5. to 2.2.8. |
CSA | A60.1-M1976 | Tuyaux en grès vitrifié | CNP 2.2.5.3. 1) CNP A-2.2.5. à 2.2.8. |
CSA | A60.3-M1976 | Vitrified Clay Pipe Joints | NPC 2.2.5.3.(2) |
CSA | A60.3-M1976 | Joints des tuyaux en grès vitrifié | CNP 2.2.5.3. 2) |
CSA | A660-10 | Certification of manufacturers of steel building systems | NBC 4.3.4.3.(1) |
CSA | A660-10 | Certification des fabricants de systèmes de bâtiment en acier | CNB 4.3.4.3. 1) |
CSA | A82.22-M1977 | Gypsum Plasters | NBC D-3.1.1. CNB D-3.1.1. |
CSA | A82.30-M1980 | Interior Furring, Lathing and Gypsum Plastering | NBC 9.29.4.1.(1) NBC D-1.7.2. NBC D-2.3.9. NBC D-2.5.1. CNB 9.29.4.1. 1) CNB D-1.7.2. CNB D-2.3.9. CNB D-2.5.1. |
CSA | A82.31-M1980 | Gypsum Board Application | NBC 3.2.3.6.(5) NBC 9.10.12.4.(3) NBC 9.10.14.5.(12) NBC 9.10.14.5.(8) NBC 9.10.15.5.(11) NBC 9.10.15.5.(7) NBC 9.10.9.2.(5) NBC 9.29.5.1.(2) NBC Table 9.10.3.1.-A |
CSA | A82.31-M1980 | Pose des plaques de plâtre | CNB 3.2.3.6. 5) CNB 9.10.12.4. 3) CNB 9.10.14.5. 12) CNB 9.10.14.5. 8) CNB 9.10.15.5. 11) CNB 9.10.15.5. 7) CNB 9.10.9.2. 5) CNB 9.29.5.1. 2) CNB Tableau 9.10.3.1.-A |
CSA | B108 |
NFC 4.6.1.1.(2) | |
CSA | COLLECTION B108 |
Contient CSA B108.1:23, Code d'installation |
CNPI 4.6.1.1. 2) |
CSA | B111-1974 | Wire Nails, Spikes and Staples | NBC 9.23.3.1.(1) NBC 9.26.2.3.(1) NBC 9.29.5.6.(1) NBC A-Table 9.23.3.5.-B CNB 9.23.3.1. 1) CNB 9.26.2.3. 1) CNB 9.29.5.6. 1) CNB A-Tableau 9.23.3.5.-B |
CSA | B125.3 |
Plumbing fittings | NPC 2.2.10.6.(1) NPC 2.2.10.7.(2) NPC 2.2.10.7.(3) NPC A-2.6.1.11.(1) CNP 2.2.10.6. 1) CNP 2.2.10.7. 2) CNP 2.2.10.7. 3) CNP A-2.6.1.11. 1) |
CSA | B137.10 |
Crosslinked polyethylene/aluminum/crosslinked polyethylene (PEX-AL-PEX) composite pressure-pipe systems | NPC 2.2.5.12.(4) NPC 2.2.5.13.(1) NPC A-2.2.5. to 2.2.8. NPC A-2.2.5.13.(1) CNP 2.2.5.12. 4) CNP 2.2.5.13. 1) CNP A-2.2.5. à 2.2.8. CNP A-2.2.5.13. 1) |
CSA | B137.11 |
Polypropylene (PP-R and PP-RCT) pipe and fittings for pressure applications | NPC 2.2.5.14.(1) NPC A-2.2.5. to 2.2.8. NPC A-2.2.5.14.(1) CNP 2.2.5.14. 1) CNP A-2.2.5. à 2.2.8. CNP A-2.2.5.14. 1) |
CSA | B137.1 |
Polyethylene (PE) pipe, tubing, and fittings for cold-water pressure services | NPC 2.2.5.4.(1) NPC A-2.2.5. to 2.2.8. CNP 2.2.5.4. 1) CNP A-2.2.5. à 2.2.8. |
CSA | B137.18 |
Polyethylene of raised temperature resistance (PE-RT) tubing systems for pressure applications | NPC 2.2.5.15.(1) NPC A-2.2.5. to 2.2.8. NPC A-2.2.5.15.(1) CNP 2.2.5.15. 1) CNP A-2.2.5. à 2.2.8. CNP A-2.2.5.15. 1) |
CSA | B137.2 |
Polyvinylchloride (PVC) injection-moulded gasketed fittings for pressure applications | NPC 2.2.5.7.(3) NPC A-2.2.5. to 2.2.8. CNP 2.2.5.7. 3) CNP A-2.2.5. à 2.2.8. |
CSA | B137.3 |
Rigid polyvinylchloride (PVC) pipe and fittings for pressure applications | NPC 2.2.5.7.(1) NPC A-2.2.5. to 2.2.8. CNP 2.2.5.7. 1) CNP A-2.2.5. à 2.2.8. |
CSA | B137.5 |
Crosslinked polyethylene (PEX) tubing systems for pressure applications | NPC 2.2.5.6.(1) NPC A-2.2.5. to 2.2.8. NPC A-2.2.5.6.(1) CNP 2.2.5.6. 1) CNP A-2.2.5. à 2.2.8. CNP A-2.2.5.6. 1) |
CSA | B137.6 |
Chlorinated polyvinylchloride (CPVC) pipe, tubing, and fittings for hot- and cold-water distribution systems | NPC 2.2.5.8.(1) NPC A-2.2.5. to 2.2.8. NPC A-2.2.5.9. to 2.2.5.11. CNP 2.2.5.8. 1) CNP A-2.2.5. à 2.2.8. CNP A-2.2.5.9. à 2.2.5.11. |
CSA | B137.9 |
Polyethylene/aluminum/polyethylene (PE-AL-PE) composite pressure-pipe systems | NPC 2.2.5.12.(1) NPC A-2.2.5. to 2.2.8. NPC A-2.2.5.12.(1) CNP 2.2.5.12. 1) CNP A-2.2.5. à 2.2.8. CNP A-2.2.5.12. 1) |
CSA | B139 Series: |
Installation code for oil-burning equipment | NBC 6.2.1.5.(1) NBC 9.31.6.2.(2) NBC 9.33.5.2.(1) NFC 4.1.1.1.(3) NFC 4.3.13.6.(1) NFC 5.6.1.10.(1) NFC A-4.1.1.1.(3)(b) NFC A-4.3.13.4.(1)(b) |
CSA | B139 Série: |
Code d'installation des appareils de combustion au mazout | CNB 6.2.1.5. 1) CNB 9.31.6.2. 2) CNB 9.33.5.2. 1) CNPI 4.1.1.1. 3) CNPI 4.3.13.6. 1) CNPI 5.6.1.10. 1) CNPI A-4.1.1.1. 3)b) CNPI A-4.3.13.4. 1)b) |
CSA | B140.12 |
Oil- |
NBC Table 9.36.4.2. NECB Table 6.2.2.1. |
CSA | B140.12 |
CNB Tableau 9.36.4.2. CNÉB Tableau 6.2.2.1. |
|
CSA | B140.4: |
Oil- |
NBC Table 9.36.3.10. NECB Table 5.2.12.1.O |
CSA | B140.4: |
Générateurs d'air chaud alimentés au mazout | CNB Tableau 9.36.3.10. CNÉB Tableau 5.2.12.1.-O |
CSA | B149.1-15 | Natural gas and propane installation code | NBC 2.4.2.2.(2) NBC 6.2.1.5.(1) NBC 9.10.22.1.(1) NBC 9.31.6.2.(2) NBC 9.33.5.2.(1) NBC A-9.10.22. NFC 3.1.1.4.(2) NFC 3.1.1.4.(3) NFC 4.6.1.1.(2) NFC 5.6.1.10.(1) |
CSA | B149.1-15 | Code d'installation du gaz naturel et du propane | CNB 2.4.2.2. 2) CNB 6.2.1.5. 1) CNB 9.10.22.1. 1) CNB 9.31.6.2. 2) CNB 9.33.5.2. 1) CNB A-9.10.22. CNPI 3.1.1.4. 2) CNPI 3.1.1.4. 3) CNPI 4.6.1.1. 2) CNPI 5.6.1.10. 1) |
CSA | B149.2-15 | Propane storage and handling code | NFC 3.1.1.4.(2) NFC 3.2.8.2.(3) NFC 4.6.1.1.(2) |
CSA | B149.2-15 | Code sur le stockage et la manipulation du propane | CNPI 3.1.1.4. 2) CNPI 3.2.8.2. 3) CNPI 4.6.1.1. 2) |
CSA | B158.1-1976 | Cast Brass Solder Joint Drainage, Waste and Vent Fittings | NPC 2.2.10.1.(1) |
CSA | B158.1-1976 | Raccords d'évacuation, d'égout et de ventilation à joint soudé en laiton de fonte | CNP 2.2.10.1. 1) |
CSA | B181.1 |
Acrylonitrile-butadiene-styrene (ABS) drain, waste, and vent pipe and pipe fittings | NPC 2.2.5.10.(1) NPC 2.2.5.11.(1) NPC 2.2.5.9.(1) NPC 2.4.6.4.(5) NPC A-2.2.5. to 2.2.8. NPC A-2.2.5.9. to 2.2.5.11. |
CSA | B181.1 |
Acrylonitrile-butadiene-styrene (ABS) drain, waste, and vent pipe and pipe fittings | CNP 2.2.5.10. 1) CNP 2.2.5.11. 1) CNP 2.2.5.9. 1) CNP 2.4.6.4. 5) CNP A-2.2.5. à 2.2.8. CNP A-2.2.5.9. à 2.2.5.11. |
CSA | B181.2 |
Polyvinylchloride (PVC) and chlorinated polyvinylchloride (CPVC) drain, waste, and vent pipe and pipe fittings | NPC 2.2.5.10.(1) NPC 2.2.5.11.(1) NPC 2.2.5.16.(1) NPC 2.2.5.16.(2) NPC 2.2.5.9.(1) NPC 2.4.6.4.(5) NPC A-2.2.5. to 2.2.8. NPC A-2.2.5.9. to 2.2.5.11. |
CSA | B181.2 |
Polyvinylchloride (PVC) and chlorinated polyvinylchloride (CPVC) drain, waste, and vent pipe and pipe fittings | CNP 2.2.5.10. 1) CNP 2.2.5.11. 1) CNP 2.2.5.16. 1) CNP 2.2.5.16. 2) CNP 2.2.5.9. 1) CNP 2.4.6.4. 5) CNP A-2.2.5. à 2.2.8. CNP A-2.2.5.9. à 2.2.5.11. |
CSA | B181.3 |
Polyolefin and polyvinylidene fluoride (PVDF) laboratory drainage systems | NPC 2.2.8.1.(1) NPC A-2.2.5. to 2.2.8. |
CSA | B181.3 |
Polyolefin and polyvinylidene fluoride (PVDF) laboratory drainage systems | CNP 2.2.8.1. 1) CNP A-2.2.5. à 2.2.8. |
CSA | B182.1 |
Plastic drain and sewer pipe and pipe fittings | NBC 9.14.3.1.(1) NBC Table 5.9.1.1. NPC 2.2.5.9.(1) NPC 2.4.6.4.(5) NPC A-2.2.5. to 2.2.8. |
CSA | B182.1 |
Plastic drain and sewer pipe and pipe fittings | CNB 9.14.3.1. 1) CNB Tableau 5.9.1.1. CNP 2.2.5.9. 1) CNP 2.4.6.4. 5) CNP A-2.2.5. à 2.2.8. |
CSA | B182.2 |
PSM type polyvinylchloride (PVC) sewer pipe and fittings | NPC 2.2.5.9.(1) NPC A-2.2.5. to 2.2.8. |
CSA | B182.2 |
PSM type polyvinylchloride (PVC) sewer pipe and fittings | CNP 2.2.5.9. 1) CNP A-2.2.5. à 2.2.8. |
CSA | B182.4 |
Profile polyvinylchloride (PVC) sewer pipe and fittings | NPC 2.2.5.9.(1) NPC A-2.2.5. to 2.2.8. |
CSA | B182.4 |
Profile polyvinylchloride (PVC) sewer pipe and fittings | CNP 2.2.5.9. 1) CNP A-2.2.5. à 2.2.8. |
CSA | B182.6 |
Profile polyethylene (PE) sewer pipe and fittings for leak-proof sewer applications | NPC 2.2.5.9.(1) NPC A-2.2.5. to 2.2.8. |
CSA | B182.6 |
Profile polyethylene (PE) sewer pipe and fittings for leak-proof sewer applications | CNP 2.2.5.9. 1) CNP A-2.2.5. à 2.2.8. |
CSA | B182.8 |
Profile polyethylene (PE) storm sewer and drainage pipe and fittings | NPC 2.2.5.9.(1) |
CSA | B182.8 |
Profile polyethylene (PE) storm sewer and drainage pipe and fittings | CNP 2.2.5.9. 1) |
CSA | B214-16 | Installation code for hydronic heating systems | NBC 6.2.1.1.(1) NBC 9.33.4.2.(1) NBC A-9.36.3.4.(1) |
CSA | B214-16 | Code d'installation des systèmes de chauffage hydronique | CNB 6.2.1.1. 1) CNB 9.33.4.2. 1) CNB A-9.36.3.4. 1) |
CSA | B242-05 | Groove- and Shoulder-Type Mechanical Pipe Couplings | NPC 2.2.10.4.(1) |
CSA | B242-05 | Raccords mécaniques pour tuyaux à rainure et à épaulement | CNP 2.2.10.4. 1) |
CSA | B272-93 | Prefabricated Self-Sealing Roof Vent Flashings | NPC 2.2.10.14.(2) |
CSA | B272-93 | Solins d'évent de toit étanches préfabriqués | CNP 2.2.10.14. 2) |
CSA | B306-M1977 | Portable Fuel Tanks for Marine Use | NFC 4.2.3.1.(1) |
CSA | B306-M1977 | Réservoirs de carburant portatifs pour bateaux | CNPI 4.2.3.1. 1) |
CSA | B346-M1980 | Power-Operated Dispensing Devices for Flammable Liquids | NFC 4.6.3.1.(1) CNPI 4.6.3.1. 1) |
CSA | B355:19 | Platform lifts and stair lifts for barrier-free access | NBC 3.8.3.7.(1) |
CSA | B355:19 | Plates-formes et appareils élévateurs d'escalier pour un accès sans obstacles | CNB 3.8.3.7. 1) |
CSA | B365-17 | Installation code for solid-fuel-burning appliances and equipment | NBC 6.2.1.5.(1) NBC 9.22.10.2.(1) NBC 9.31.6.2.(2) NBC 9.33.5.3.(1) NBC A-9.33.1.1.(2) NBC A-9.33.5.3. |
CSA | B365-17 | Code d'installation des appareils à combustibles solides et du matériel connexe | CNB 6.2.1.5. 1) CNB 9.22.10.2. 1) CNB 9.31.6.2. 2) CNB 9.33.5.3. 1) CNB A-9.33.1.1. 2) CNB A-9.33.5.3. |
CSA | B376-M1980 | Portable Containers for Gasoline and Other Petroleum Fuels | NFC 4.2.3.1.(1) |
CSA | B376-M1980 | Réservoirs portatifs pour l'essence et autres combustibles de pétrole | CNPI 4.2.3.1. 1) |
CSA | B415.1-10 | Performance Testing of Solid-Fuel-Burning Heating Appliances | NBC Table 9.36.3.10. NECB Table 5.2.12.1.P |
CSA | B415.1-10 | Essais de rendement des appareils de chauffage à combustibles solides | CNB Tableau 9.36.3.10. CNÉB Tableau 5.2.12.1.-P |
CSA | B481.0-12 | Material, design, and construction requirements for grease interceptors | NPC 2.2.3.2.(3) |
CSA | B481.0-12 | Exigences relatives aux matériaux, à la conception et à la construction des séparateurs de graisses | CNP 2.2.3.2. 3) |
CSA | B481.3-12 | Sizing, selection, location, and installation of grease interceptors | NPC 2.2.3.2.(3) |
CSA | B481.3-12 | Choix de la taille, du modèle et de l'emplacement des séparateurs de graisses, et leur installation | CNP 2.2.3.2. 3) |
CSA | B481.4-12 | Maintenance of grease interceptors | NPC A-2.2.3.2.(3) |
CSA | B481.4-12 | Entretien des séparateurs de graisses | CNP A-2.2.3.2. 3) |
CSA | B51: |
Boiler, pressure vessel, and pressure piping code | NBC 6.2.1.5.(1) NBC 9.31.6.2.(2) NBC 9.33.5.2.(1) NFC 4.3.1.3.(2) |
CSA | B51: |
CNB 6.2.1.5. 1) CNB 9.31.6.2. 2) CNB 9.33.5.2. 1) CNPI 4.3.1.3. 2) |
|
CSA | B52: |
Mechanical refrigeration code | NBC 6.2.1.5.(1) NBC 9.33.5.2.(1) |
CSA | B52: |
Code sur la réfrigération mécanique | CNB 6.2.1.5. 1) CNB 9.33.5.2. 1) |
CSA | B55.1:15 | Test method for measuring efficiency and pressure loss of drain water heat recovery units | NBC 9.36.5.12.(2) |
CSA | B55.1:15 | Méthode d'essai pour la mesure de l'efficacité et de la perte de charge des récupérateurs de chaleur des eaux grises | CNB 9.36.5.12. 2) |
CSA | B602-16 | Mechanical couplings for drain, waste, and vent pipe and sewer pipe | NPC 2.2.10.4.(2) |
CSA | B602-16 | Joints mécaniques pour tuyaux d'évacuation, de ventilation et d'égout | CNP 2.2.10.4. 2) |
CSA | B620 |
Highway tanks and TC portable tanks for the transportation of dangerous goods | NFC 4.2.3.1.(1) |
CSA | B620 |
Citernes routières et citernes amovibles TC pour le transport des marchandises dangereuses | CNPI 4.2.3.1. 1) |
CSA | B64.0-11 | Definitions, general requirements, and test methods for vacuum breakers and backflow preventers | NPC 2.2.10.10.(1) |
CSA | B64.0-11 | Définitions, exigences générales et méthodes d'essai relatives aux casse-vide et aux dispositifs antirefoulement | CNP 2.2.10.10. 1) |
CSA | CSA B64.10 |
Selection and installation of backflow preventers/Maintenance and field testing of backflow preventers | NPC 2.6.2.1.(3) |
CSA | CSA B64.10 |
Sélection et installation des dispositifs antirefoulement/Entretien et mise à l'essai à pied d'oeuvre des dispositifs antirefoulement | CNP 2.6.2.1. 3) |
CSA | B64.1.1-11 | Atmospheric vacuum breakers (AVB) | NPC 2.2.10.10.(1) |
CSA | B64.1.1-11 | Casse-vide atmosphériques (C-VA) | CNP 2.2.10.10. 1) |
CSA | B64.1.2-11 | Pressure vacuum breakers (PVB) | NPC 2.2.10.10.(1) |
CSA | B64.1.2-11 | Casse-vide à pression (C-VP) | CNP 2.2.10.10. 1) |
CSA | B64.1.3-11 | Spill-resistant pressure vacuum breakers (SRPVB) | NPC 2.2.10.10.(1) |
CSA | B64.1.3-11 | Casse-vide à pression antidéversement (C-VPAD) | CNP 2.2.10.10. 1) |
CSA | B64.2-11 | Hose connection vacuum breakers (HCVB) | NPC 2.2.10.10.(1) |
CSA | B64.2-11 | Casse-vide à raccordement de flexible (C-VRF) | CNP 2.2.10.10. 1) |
CSA | B64.2.1-11 | Hose connection vacuum breakers (HCVB) with manual draining feature | NPC 2.2.10.10.(1) |
CSA | B64.2.1-11 | Casse-vide à raccordement de flexible (C-VRF) à vidange manuelle | CNP 2.2.10.10. 1) |
CSA | B64.2.2-11 | Hose connection vacuum breakers (HCVB) with automatic draining feature | NPC 2.2.10.10.(1) |
CSA | B64.2.2-11 | Casse-vide à raccordement de flexible (C-VRF) à vidange automatique | CNP 2.2.10.10. 1) |
CSA | B64.3-11 | Dual check valve backflow preventers with atmospheric port (DCAP) | NPC 2.2.10.10.(1) |
CSA | B64.3-11 | Dispositifs antirefoulement à deux clapets de retenue à orifice de décharge (DArOD) | CNP 2.2.10.10. 1) |
CSA | B64.4-11 | Reduced pressure principle (RP) backflow preventers | NPC 2.2.10.10.(1) NPC 2.6.2.4.(2) |
CSA | B64.4-11 | Dispositif antirefoulement à pression réduite (DArPR) | CNP 2.2.10.10. 1) CNP 2.6.2.4. 2) |
CSA | B64.4.1-11 | Reduced pressure principle backflow preventers for fire protection systems (RPF) | NPC 2.2.10.10.(1) NPC 2.6.2.4.(2) NPC 2.6.2.4.(4) NPC A-2.6.2.4.(2) |
CSA | B64.4.1-11 | Dispositifs antirefoulement à pression réduite pour les systèmes de protection incendie (DArPRI) | CNP 2.2.10.10. 1) CNP 2.6.2.4. 2) CNP 2.6.2.4. 4) CNP A-2.6.2.4. 2) |
CSA | B64.5-11 | Double check valve (DCVA) backflow preventers | NPC 2.2.10.10.(1) NPC 2.6.2.4.(2) |
CSA | B64.5-11 | Dispositifs antirefoulement à deux clapets de retenue et robinets (DAr2CR) | CNP 2.2.10.10. 1) CNP 2.6.2.4. 2) |
CSA | B64.5.1-11 | Double check valve backflow preventers for fire protection systems (DCVAF) | NPC 2.2.10.10.(1) NPC 2.6.2.4.(2) NPC A-2.6.2.4.(2) |
CSA | B64.5.1-11 | Dispositifs antirefoulement à deux clapets de retenue et robinets pour les systèmes de protection incendie (DAr2CRI) | CNP 2.2.10.10. 1) CNP 2.6.2.4. 2) CNP A-2.6.2.4. 2) |
CSA | B64.6-11 | Dual check valve (DuC) backflow preventers | NPC 2.2.10.10.(1) NPC 2.6.2.4.(2) |
CSA | B64.6-11 | Dispositifs antirefoulement à deux clapets de retenue (DAr2C) | CNP 2.2.10.10. 1) CNP 2.6.2.4. 2) |
CSA | B64.6.1-11 | Dual check valve backflow preventers for fire protection systems (DuCF) | NPC 2.2.10.10.(1) NPC 2.6.2.4.(2) NPC A-2.6.2.4.(2) |
CSA | B64.6.1-11 | Dispositifs antirefoulement à deux clapets de retenue pour les systèmes de protection incendie (DAr2CI) | CNP 2.2.10.10. 1) CNP 2.6.2.4. 2) CNP A-2.6.2.4. 2) |
CSA | B64.7-11 | Laboratory faucet vacuum breakers (LFVB) | NPC 2.2.10.10.(1) |
CSA | B64.7-11 | Casse-vide pour robinet de laboratoire (C-VRL) | CNP 2.2.10.10. 1) |
CSA | B64.8-11 | Dual check valve backflow preventers with intermediate vent (DuCV) | NPC 2.2.10.10.(1) |
CSA | B64.8-11 | Dispositif antirefoulement à deux clapets de retenue à ventilation intermédiaire (DAr2CV) | CNP 2.2.10.10. 1) |
CSA | B64.9-11 | Single check valve backflow preventers for fire protection systems (SCVAF) | NPC 2.2.10.10.(1) NPC 2.6.2.4.(2) NPC A-2.6.2.4.(2) |
CSA | B64.9-11 | Dispositif antirefoulement à un clapet de retenue pour les systèmes de protection incendie (DAr1CI) | CNP 2.2.10.10. 1) CNP 2.6.2.4. 2) CNP A-2.6.2.4. 2) |
CSA | B651-18 | Accessible design for the built environment | NBC 3.3.1.19.(1) NBC 3.8.3.1.(1) NBC 3.8.3.3.(1) NBC 3.8.3.9.(1) NBC 3.8.3.9.(2) NBC A-3.8.3.1.(1) NBC Table 3.8.3.1. |
CSA | B651-18 | Conception accessible pour l'environnement bâti | CNB 3.3.1.19. 1) CNB 3.8.3.1. 1) CNB 3.8.3.3. 1) CNB 3.8.3.9. 1) CNB 3.8.3.9. 2) CNB A-3.8.3.1. 1) CNB Tableau 3.8.3.1. |
CSA | B70.1 |
Frames and |
NPC 2.2.6.2.(1) |
CSA | B70.1 |
CNP 2.2.6.2. 1) | |
CSA | B70-12 | Cast iron soil pipe, fittings, and means of joining | NPC 2.2.6.1.(1) NPC 2.4.6.4.(5) NPC A-2.2.5. to 2.2.8. |
CSA | B70-12 | Tuyaux et raccords d'évacuation d'eaux usées en fonte et méthodes de raccordement | CNP 2.2.6.1. 1) CNP 2.4.6.4. 5) CNP A-2.2.5. à 2.2.8. |
CSA | CAN/CSA A82.27-M91 | Gypsum Board | NBC 3.1.5.14.(6) NBC 3.1.5.15.(4) NBC 3.1.6.15.(1) NBC 3.1.6.6.(2) NBC D-1.5.1. NBC D-3.1.1. |
CSA | CAN/CSA A82.27-M91 | Plaques de plâtre | CNB 3.1.5.14. 6) CNB 3.1.5.15. 4) CNB 3.1.6.15. 1) CNB 3.1.6.6. 2) CNB D-1.5.1. CNB D-3.1.1. |
CSA | CAN/CSA-A123.16:04 | Asphalt-coated glass-base sheets | NBC Table 5.9.1.1. NBC Table 9.26.2.1.B |
CSA | CAN/CSA-A123.16:04 | Membranes d'étanchéité bitumées et à base de fibres de verre | CNB Tableau 5.9.1.1. CNB Tableau 9.26.2.1.B |
CSA | CAN/CSA-A123.2-03 | Asphalt-Coated Roofing Sheets | NBC 9.13.3.2.(2) NBC Table 5.9.1.1. NBC Table 9.26.2.1.B |
CSA | CAN/CSA-A123.2-03 | Feutre à toiture revêtu de bitume | CNB 9.13.3.2. 2) CNB Tableau 5.9.1.1. CNB Tableau 9.26.2.1.B |
CSA | CAN/CSA-A123.21:14 | Standard test method for the dynamic wind uplift resistance of membrane-roofing systems | NBC 5.2.2.2.(4) NBC A-5.2.2.2.(4) |
CSA | CAN/CSA-A123.21:14 | Méthode d'essai normalisée de la résistance dynamique à l'arrachement sous l'action du vent des systèmes de couverture à membrane | CNB 5.2.2.2. 4) CNB A-5.2.2.2. 4) |
CSA | CAN/CSA-A123.4-04 | Asphalt for Constructing Built-Up Roof Coverings and Waterproofing Systems | NBC 9.13.2.2.(2) NBC 9.13.3.2.(2) NBC Table 5.9.1.1. NBC Table 9.26.2.1.B |
CSA | CAN/CSA-A123.4-04 | Bitume utilisé pour l'imperméabilisation de revêtements multicouches pour toitures | CNB 9.13.2.2. 2) CNB 9.13.3.2. 2) CNB Tableau 5.9.1.1. CNB Tableau 9.26.2.1.B |
CSA | CAN/CSA-A179-14 | Mortar and Grout for Unit Masonry | NBC 9.15.2.2.(3) NBC 9.20.3.1.(1) NBC Table 5.9.1.1. |
CSA | CAN/CSA-A179-14 | Mortier et coulis pour la maçonnerie en éléments | CNB 9.15.2.2. 3) CNB 9.20.3.1. 1) CNB Tableau 5.9.1.1. |
CSA | CAN/CSA-A220 Series-06 | Concrete Roof Tiles | NBC 9.26.17.1.(1) NBC Table 5.9.1.1. NBC Table 9.26.2.1.B |
CSA | CAN/CSA-A324-M88 | Clay Flue Liners | NBC 9.21.3.3.(1) |
CSA | CAN/CSA-A324-M88 | Boisseaux en argile pour conduits de fumée | CNB 9.21.3.3. 1) |
CSA | CAN/CSA-A370:14 | Connectors for masonry | NBC A-9.21.4.5.(2) |
CSA | CAN/CSA-A370:14 | Connecteurs pour la maçonnerie | CNB A-9.21.4.5. 2) |
CSA | CAN/CSA-A371-14 | Masonry Construction for Buildings | NBC 9.15.2.2.(3) NBC 9.20.15.2.(1) NBC 9.20.3.2.(7) NBC Table 5.9.1.1. |
CSA | CAN/CSA-A371-14 | Maçonnerie des bâtiments | CNB 9.15.2.2. 3) CNB 9.20.15.2. 1) CNB 9.20.3.2. 7) CNB Tableau 5.9.1.1. |
CSA | CAN/CSA-A405-M87 | Design and Construction of Masonry Chimneys and Fireplaces | NBC 9.21.3.5.(1) NBC 9.22.1.4.(1) NBC 9.22.5.2.(2) |
CSA | CAN/CSA-A405-M87 | Conception et construction des foyers et cheminées en maçonnerie | CNB 9.21.3.5. 1) CNB 9.22.1.4. 1) CNB 9.22.5.2. 2) |
CSA | CAN/CSA-A82:14 | Fired masonry brick made from clay or shale | NBC 9.20.2.1.(1) NBC D-2.6.1. NBC Table 5.9.1.1. |
CSA | CAN/CSA-A82:14 | Brique de maçonnerie cuite en argile ou en schiste | CNB 9.20.2.1. 1) CNB D-2.6.1. CNB Tableau 5.9.1.1. |
CSA | CAN/CSA-A82.27-M91 | Plaques de plâtre | CNB 3.1.5.14. 6) CNB 3.1.5.15. 4) CNB 3.1.6.15. 1) CNB 3.1.6.6. 2) CNB D-1.5.1. CNB D-3.1.1. |
CSA | CAN/CSA-B126.0-13 | General requirements and methods of testing for water cisterns | NPC 2.7.2.4.(6) |
CSA | CAN/CSA-B126.0-13 | Exigences générales et méthodes d'essai des réservoirs d'eau | CNP 2.7.2.4. 6) |
CSA | CAN/CSA-B126.1-13 | Installation of water cisterns | NPC 2.7.2.4.(6) |
CSA | CAN/CSA-B126.1-13 | Installation des réservoirs d'eau | CNP 2.7.2.4. 6) |
CSA | CAN/CSA-B127.3-18 | Fibrocement drain, waste, and vent pipe and pipe fittings | NPC 2.2.5.1.(1) NPC A-2.2.5. to 2.2.8. |
CSA | CAN/CSA-B127.3-18 | Fibrocement drain, waste, and vent pipe and pipe fittings | CNP 2.2.5.1. 1) CNP A-2.2.5. à 2.2.8. |
CSA | CAN/CSA-B128.1-06 | Design and Installation of Non-Potable Water Systems | NPC 2.7.1.2.(1) NPC A-2.7.1.1.(1) |
CSA | CAN/CSA-B128.1-06 | Conception et installation des réseaux d'eau non potable | CNP 2.7.1.2. 1) CNP A-2.7.1.1. 1) |
CSA | CAN/CSA-B211-00 | Energy Efficiency of Oil-Fired Storage Tank Water Heaters | NBC Table 9.36.4.2. NECB Table 6.2.2.1. |
CSA | CAN/CSA-B211-00 | Rendement énergétique des chauffe-eau au mazout à accumulation | CNB Tableau 9.36.4.2. CNÉB Tableau 6.2.2.1. |
CSA | Water pressure reducing valves for |
NPC 2.2.10.12.(1) | |
CSA | CNP 2.2.10.12. 1) | ||
CSA | CAN/CSA-B45 Series-02 | Plumbing Fixtures | NPC 2.2.2.2.(1) |
CSA | CAN/CSA-B483.1-07 | Drinking Water Treatment Systems | NPC 2.2.10.17.(1) |
CSA | CAN/CSA-B483.1-07 | Systèmes de traitement de l'eau potable | CNP 2.2.10.17. 1) |
CSA | CAN/CSA-B72-M87 | Installation Code for Lightning Protection Systems | NBC 3.6.1.3.(1) |
CSA | CAN/CSA-B72-M87 | Code d'installation des paratonnerres | CNB 3.6.1.3. 1) |
CSA | CAN/CSA-B72-M87 | Code d'installation des paratonnerres | CNB 3.6.1.3. 1) |
CSA | CAN/CSA-C13256-1-01 | Water-Source Heat Pumps - Testing and Rating for Performance - Part 1: Water-to-Air and Brine-to-Air Heat Pumps (Adopted ISO 13256-1:1998, first edition, 1998-08-15, with Canadian Deviations) | NBC Table 9.36.3.10. NECB Table 5.2.12.1.E |
CSA | CAN/CSA-C13256-1-01 | Pompes à chaleur à eau - Essais et détermination des caractéristiques de performance - Partie 1 : Pompes à chaleur eau-air et eau glycolée-air (norme ISO 13256-1 : 1998 adoptée, première édition, 1998-08-15, avec exigences propres au Canada) | CNB Tableau 9.36.3.10. CNÉB Tableau 5.2.12.1.-E |
CSA | CAN/CSA-C13256-2-01 | Water-Source Heat Pumps - Testing and Rating for Performance - Part 2: Water-to-Water and Brine-to-Water Heat Pumps (Adopted ISO 13256-2:1998, first edition, 1998-08-15, with Canadian Deviations) | NBC Table 9.36.3.10. NECB Table 5.2.12.1.E |
CSA | CAN/CSA-C13256-2-01 | Pompes à chaleur à eau - Essais et détermination des caractéristiques de performance - Partie 2 : Pompes à chaleur eau-eau et eau glycolée-eau (norme ISO 13256-2 : 1998 adoptée, première édition, 1998-08-15, avec exigences propres au Canada) | CNB Tableau 9.36.3.10. CNÉB Tableau 5.2.12.1.-E |
CSA | CAN/CSA-C191- |
Performance of |
NBC Table 9.36.4.2. NECB Table 6.2.2.1. |
CSA | CAN/CSA-C191- |
Fonctionnement des chauffe-eau électriques à accumulation pour usage domestique | CNB Tableau 9.36.4.2. CNÉB Tableau 6.2.2.1. |
CSA | CAN/CSA-C22.2 N° 262-04 | Canalisations pour câbles à fibres optiques et câbles de télécommunications | CNB 3.1.5.23. 1) |
CSA | CAN/CSA-C22.2 N° 61010-1-12 | Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire - Partie 1 : Exigences générales (norme trinationale avec UL 61010-1 et ANSI/ISA-61010-1 (82.02.01) | CNPI A-5.5.3.4. 1) |
CSA | CAN/CSA-C22.2 No. 150-M89 | Microwave Ovens | NBC A-9.10.22. |
CSA | CAN/CSA-C22.2 No. 150-M89 | Fours à micro-ondes | CNB A-9.10.22. |
CSA | CAN/CSA-C22.2 No. 262-04 | Optical Fiber Cable and Communication Cable Raceway Systems | NBC 3.1.5.23.(1) |
CSA | CAN/CSA-C22.2 No. 61010-1-12 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements (Tri-national standard, with UL 61010-1 and ANSI/ISA-61010-1 (82.02.01) | NFC A-5.5.3.4.(1) |
CSA | CAN/CSA-C260-M90 | Rating the Performance of Residential Mechanical Ventilating Equipment | NBC 9.32.3.10.(1) NBC 9.32.3.10.(2) NBC Table 9.32.3.10.B |
CSA | CAN/CSA-C260-M90 | Évaluation du rendement du matériel de ventilation mécanique pour habitations | CNB 9.32.3.10. 1) CNB 9.32.3.10. 2) CNB Tableau 9.32.3.10.B |
CSA | CAN/CSA-C439- |
NBC 9.32.3.10.(4) NBC 9.32.3.10.(5) NBC 9.36.3.8.(4) NBC 9.36.3.9.(3) NBC A-9.36.3.9.(3) NECB 5.2.10.1.(5) NECB 5.2.10.4.(2) NECB A-5.2.10.4.(2) NECB Table 5.2.10.4. |
|
CSA | CAN/CSA-C439- |
CNB 9.32.3.10. 4) CNB 9.32.3.10. 5) CNB 9.36.3.8. 4) CNB 9.36.3.9. 3) CNB A-9.36.3.9. 3) CNÉB 5.2.10.1. 5) CNÉB 5.2.10.4. 2) CNÉB A-5.2.10.4. 2) CNÉB Tableau 5.2.10.4. |
|
CSA | CAN/CSA-C448 Series-13 | Design and installation of earth energy systems | NBC 9.33.5.2.(1) CNB 9.33.5.2. 1) |
CSA | CAN/CSA-C654-14 | Fluorescent lamp ballast efficacy measurements | NECB 4.2.1.2.(1) NECB 4.2.1.2.(2) |
CSA | CAN/CSA-C654-14 | Mesures de rendement des ballasts de lampe fluorescente | CNÉB 4.2.1.2. 1) CNÉB 4.2.1.2. 2) |
CSA | CAN/CSA-C743-09 | Performance standard for rating packaged water chillers | NECB Table 5.2.12.1.K NECB Table 5.2.12.1.L |
CSA | CAN/CSA-C743-09 | Évaluation des performances des refroidisseurs d'eau monoblocs | CNÉB Tableau 5.2.12.1.-K CNÉB Tableau 5.2.12.1.-L |
CSA | CAN/CSA-C745-03 | Energy Efficiency of Electric Storage Tank Water Heaters and Heat Pump Water Heaters | NBC Table 9.36.4.2. NBC Table 9.36.8.10. NECB Table 6.2.2.1. |
CSA | CAN/CSA-C745-03 | Rendement énergétique des chauffe-eau électriques à accumulation et des chauffe-eau à pompe à chaleur | CNB Tableau 9.36.4.2. CNB Tableau 9.36.8.10. CNÉB Tableau 6.2.2.1. |
CSA | CAN/CSA-C746 |
NBC Table 9.36.3.10. NECB Table 5.2.12.1.A NECB Table 5.2.12.1.B NECB Table 5.2.12.1.C NECB Table 5.2.12.1.D |
|
CSA | CAN/CSA-C746 |
Évaluation des performances énergétiques des climatiseurs et des thermopompes de grande puissance et |
CNB Tableau 9.36.3.10. CNÉB Tableau 5.2.12.1.-A CNÉB Tableau 5.2.12.1.-B CNÉB Tableau 5.2.12.1.-C CNÉB Tableau 5.2.12.1.-D |
CSA | CAN/CSA-C749-07 | Performance of Dehumidifiers | NBC Table 9.36.3.10. |
CSA | CAN/CSA-C749-07 | Performances des déshumidificateurs | CNB Tableau 9.36.3.10. |
CSA | Minimum efficiency values for liquid-filled distribution transformers | NECB 7.2.3.1.(1) | |
CSA | Valeurs minimales de rendement pour les transformateurs de distribution à isolant liquide | CNÉB 7.2.3.1. 1) | |
CSA | CAN/CSA-C802.2-18 | Test method and minimum efficiency values for dry-type transformers | NECB 7.2.3.1.(1) |
CSA | CAN/CSA-C802.2:18 | Méthode d'essai et valeurs minimales de rendement pour les transformateurs à sec | CNÉB 7.2.3.1. 1) |
CSA | CAN/CSA-C828-13 | Performance requirements for thermostats used with individual room electric space heating devices | NBC 9.36.3.6.(3) NECB 5.2.8.6.(4) |
CSA | CAN/CSA-C828-13 | Exigences relatives aux performances des thermostats dédiés au chauffage électrique par pièce | CNB 9.36.3.6. 3) CNÉB 5.2.8.6. 4) |
CSA | CAN/CSA-C860-11 | Performance of internally lighted exit signs | NECB 4.2.1.1.(1) |
CSA | CAN/CSA-C860-11 | Performances des enseignes de sortie à éclairage interne | CNÉB 4.2.1.1. 1) |
CSA | Residential |
NBC 9.32.3.1.(1) NBC A-9.32.3.1.(1) NBC A-9.32.3.5. NBC A-9.32.3.7. NBC A-9.32.3.8. NBC A-9.33.6.13. |
|
CSA | CNB 9.32.3.1. 1) CNB A-9.32.3.1. 1) CNB A-9.32.3.5. CNB A-9.32.3.7. CNB A-9.32.3.8. CNB A-9.33.6.13. |
||
CSA | CAN/CSA-F379 SERIES-09 (excluding Supplement F379S1-11) | Packaged solar domestic hot water systems (liquid-to-liquid heat transfer) | NPC 2.2.10.13.(1) NECB 6.2.2.3.(1) |
CSA | CAN/CSA-F379 SÉRIE-09 (à l'exclusion du Supplément F379S1-11) | Chauffe-eau solaires d'usage ménager intégrés (transfert de chaleur liquide-liquide) | CNP 2.2.10.13. 1) CNÉB 6.2.2.3. 1) |
CSA | CAN/CSA-F383-08 | Installation of packaged solar domestic hot water systems | NPC 2.6.1.8.(1) |
CSA | CAN/CSA-F383-08 | Installation des chauffe-eau solaires d'usage ménager intégrés | CNP 2.6.1.8. 1) |
CSA | Corrugated steel pipe |
NBC 9.14.3.1.(1) NBC Table 5.9.1.1. NPC 2.2.6.8.(1) NPC A-2.2.5. to 2.2.8. |
|
CSA | Tuyaux en tôle ondulée et ouvrages enfouis | CNB 9.14.3.1. 1) CNB Tableau 5.9.1.1. CNP 2.2.6.8. 1) CNP A-2.2.5. à 2.2.8. |
|
CSA | CAN/CSA-O122-16 | Structural glued-laminated timber | NBC Table 9.23.12.3.-D NBC Table 9.23.4.2.-K |
CSA | CAN/CSA-O122-16 | Bois de charpente lamellé-collé | CNB Tableau 9.23.12.3.-D CNB Tableau 9.23.4.2.-K |
CSA | CAN/CSA-O132.2 Series-90 | Wood Flush Doors | NBC 9.7.4.3.(4) |
CSA | CAN/CSA-O132.2 Série-90 | Portes planes en bois | CNB 9.7.4.3. 4) |
CSA | CAN/CSA-O80 Series-15 | Wood preservation | NBC 3.1.4.5.(1) NBC 4.2.3.2.(1) NBC Table 5.9.1.1. |
CSA | CAN/CSA-O80 Série-15 | Préservation du bois | CNB 3.1.4.5. 1) CNB 4.2.3.2. 1) CNB Tableau 5.9.1.1. |
CSA | CAN/CSA-O80.0-15 | General requirements for wood preservation | NBC 4.2.3.2.(2) |
CSA | CAN/CSA-O80.0-15 | Exigences générales relatives à la préservation du bois | CNB 4.2.3.2. 2) |
CSA | CAN/CSA-O80.1-15 | Specification of treated wood | NBC 4.2.3.2.(1) NBC 9.3.2.9.(5) |
CSA | CAN/CSA-O80.1-15 | Rédaction de devis pour le bois traité | CNB 4.2.3.2. 1) CNB 9.3.2.9. 5) |
CSA | CAN/CSA-O80.2-15 | Processing and treatment | NBC 4.2.3.2.(1) |
CSA | CAN/CSA-O80.2-15 | Traitement | CNB 4.2.3.2. 1) |
CSA | CAN/CSA-O80.3-15 | Preservative formulations | NBC 4.2.3.2.(1) |
CSA | CAN/CSA-O80.3-15 | Formules relatives aux produits de préservation | CNB 4.2.3.2. 1) |
CSA | CAN/CSA-P.11-07 | Testing Method for Measuring Efficiency and Energy Consumption of Gas-Fired Unit Heaters | NBC Table 9.36.3.10. NECB Table 5.2.12.1.O |
CSA | CAN/CSA-P.11-07 | Méthode d'essai pour mesurer l'efficacité et la consommation énergétique des aérothermes à gaz | CNB Tableau 9.36.3.10. CNÉB Tableau 5.2.12.1.-O |
CSA | CAN/CSA-P.2-13 | Testing method for measuring the annual fuel utilization efficiency of residential gas-fired or oil-fired furnaces and boilers | NBC Table 9.36.3.10. NECB Table 5.2.12.1.N NECB Table 5.2.12.1.O |
CSA | CAN/CSA-P.2-13 | Méthode d'essai pour mesurer le taux d'utilisation annuel de combustible des chaudières et générateurs d'air chaud à gaz ou à mazout résidentiels | CNB Tableau 9.36.3.10. CNÉB Tableau 5.2.12.1.-N CNÉB Tableau 5.2.12.1.-O |
CSA | CAN/CSA-P.3-15 | Testing method for measuring energy consumption and determining efficiencies of gas-fired and fuel oil-fired water heaters | NBC Table 9.36.4.2. NBC Table 9.36.8.10. NECB Table 6.2.2.1. |
CSA | CAN/CSA-P.3-15 | Méthode d'essai pour mesurer la consommation d'énergie et le rendement énergétique des chauffe-eau au gaz et au mazout | CNB Tableau 9.36.4.2. CNB Tableau 9.36.8.10. CNÉB Tableau 6.2.2.1. |
CSA | Testing method for measuring |
NBC Table 9.36.3.10. NECB Table 5.2.12.1.P |
|
CSA | Méthode d'essai pour mesurer l'efficacité |
CNB Tableau 9.36.3.10. CNÉB Tableau 5.2.12.1.-P |
|
CSA | Thermal efficiencies of industrial and commercial gas-fired package furnaces | NBC Table 9.36.3.10. NECB Table 5.2.12.1.O |
|
CSA | Rendement thermique des générateurs autonomes d'air chaud à gaz |
CNB Tableau 9.36.3.10. CNÉB Tableau 5.2.12.1.-O |
|
CSA | CAN/CSA-P.9-11 | Test method for determining the performance of combined space and water heating systems (combos) | NBC 9.36.3.10.(3) NBC Table 9.36.3.10. NBC Table 9.36.4.2. NBC Table 9.36.5.15.C |
CSA | CAN/CSA-P.9-11 | Méthode d'essai pour déterminer le rendement des systèmes combinés de chauffage des locaux et de l'eau (combos) | CNB 9.36.3.10. 3) CNB Tableau 9.36.3.10. CNB Tableau 9.36.4.2. CNB Tableau 9.36.5.15.C |
CSA | CAN/CSA-Série A220-06 | Tuiles en béton pour couvertures | CNB 9.26.17.1. 1) CNB Tableau 5.9.1.1. CNB Tableau 9.26.2.1.B |
CSA | CAN/CSA-Série B45-02 | Appareils sanitaires | CNP 2.2.2.2. 1) |
CSA | CAN/CSA-S269.3-M92 | Concrete Formwork | NBC 4.1.1.3.(4) |
CSA | CAN/CSA-S269.3-M92 | Coffrages | CNB 4.1.1.3. 4) |
CSA | Antennas, towers, and antenna-supporting structures | NBC 4.1.6.15.(1) NBC 4.1.7.11.(1) CNB 4.1.6.15. 1) CNB 4.1.7.11. 1) |
|
CSA | CAN/CSA-Z317.2-15 | Special requirements for heating, ventilation, and air-conditioning (HVAC) systems in health care facilities | NBC 6.2.1.1.(1) NBC 6.3.2.15.(6) |
CSA | CAN/CSA-Z317.2-15 | Systèmes de chauffage, de ventilation et de conditionnement d'air (CVCA) dans les établissements de santé : exigences particulières | CNB 6.2.1.1. 1) CNB 6.3.2.15. 6) |
CSA | Oil and gas pipeline systems | NBC 3.2.3.22.(1) | |
CSA | Réseaux de canalisations de pétrole et de gaz | CNB 3.2.3.22. 1) | |
CSA | CAN3-A93-M82 | Natural Airflow Ventilators for Buildings | NBC 9.19.1.2.(5) NBC Table 5.9.1.1. |
CSA | CAN3-A93-M82 | Évents d'aération de bâtiments | CNB 9.19.1.2. 5) CNB Tableau 5.9.1.1. |
CSA | CSA B45.5 |
Plastic plumbing fixtures | NPC 2.2.2.2.(1) CNP 2.2.2.2. 1) |
CSA | C22.1 |
Canadian Electrical Code, Part I ( |
NBC 2.2.1.15.(1) NBC 3.3.6.2.(4) NBC 3.6.1.2.(1) NBC 3.6.2.1.(6) NBC 3.6.2.7.(1) NBC 6.2.1.5.(1) NBC 9.31.6.2.(2) NBC 9.33.5.2.(1) NBC 9.34.1.1.(1) NBC A-3.1.4.3.(1)(b)(i) NBC A-3.2.4.20.(9)(a) NBC A-3.3.6.2.(4) NBC A-9.10.22. NBC A-9.34.2. NBC A-9.35.2.2.(1) NFC 2.14.1.1.(1) NFC 4.1.4.1.(1) NFC 4.1.4.1.(2) NFC 5.1.2.1.(1) NFC 5.1.2.2.(1) NFC 5.3.1.10.(2) NFC 5.3.1.2.(2) NFC 5.3.1.2.(3) NFC 5.5.3.4.(1) NFC 5.6.1.9.(3) NFC A-4.10.3.3.(1) NFC A-5.1.2.1.(1) NFC A-5.5.3.4.(1) NECB A-7.2.1.1. |
CSA | C22.1 |
Code canadien de l'électricité, |
CNB 2.2.1.15. 1) CNB 3.3.6.2. 4) CNB 3.6.1.2. 1) CNB 3.6.2.1. 6) CNB 3.6.2.7. 1) CNB 6.2.1.5. 1) CNB 9.31.6.2. 2) CNB 9.33.5.2. 1) CNB 9.34.1.1. 1) CNB A-3.1.4.3. 1)b)i) CNB A-3.2.4.20. 9)a) CNB A-3.3.6.2. 4) CNB A-9.10.22. CNB A-9.34.2. CNB A-9.35.2.2. 1) CNPI 2.14.1.1. 1) CNPI 4.1.4.1. 1) CNPI 4.1.4.1. 2) CNPI 5.1.2.1. 1) CNPI 5.1.2.2. 1) CNPI 5.3.1.10. 2) CNPI 5.3.1.2. 2) CNPI 5.3.1.2. 3) CNPI 5.5.3.4. 1) CNPI 5.6.1.9. 3) CNPI A-4.10.3.3. 1) CNPI A-5.1.2.1. 1) CNPI A-5.5.3.4. 1) CNÉB A-7.2.1.1. |
CSA | C22.2 N° 0.3-09 | Test Methods for Electrical Wires and Cables | CNB 3.1.4.3. 1) CNB 3.1.4.3. 3) CNB 3.1.5.21. 1) CNB 3.1.5.21. 3) CNB 9.34.1.5. 1) |
CSA | C22.2 N° 113 |
CNB 9.32.3.10. 7) | |
CSA | C22.2 N° 141:15 | Emergency Lighting Equipment | CNB 3.2.7.4. 2) CNB 3.4.5.1. 3) CNB 9.9.11.3. 3) CNB 9.9.12.3. 7) |
CSA | C22.2 N° 211.0-03 | General Requirements and Methods of Testing for Nonmetallic Conduit | CNB 3.1.5.23. 1) |
CSA | C22.2 No. 0.3-09 | Test methods for electrical wires and cables | NBC 3.1.4.3.(1) NBC 3.1.4.3.(3) NBC 3.1.5.21.(1) NBC 3.1.5.21.(3) NBC 9.34.1.5.(1) |
CSA | C22.2 No. 113 |
Fans and |
NBC 9.32.3.10.(7) |
CSA | C22.2 No. 141:15 | Emergency lighting equipment | NBC 3.2.7.4.(2) NBC 3.4.5.1.(3) NBC 9.9.11.3.(3) NBC 9.9.12.3.(7) |
CSA | C22.2 No. 211.0-03 | General Requirements and Methods of Testing for Nonmetallic Conduit | NBC 3.1.5.23.(1) |
CSA | C282 |
Emergency electrical power supply for buildings | NBC 3.2.7.5.(1) NFC 6.5.1.1.(1) NFC 6.5.1.4.(1) NFC A-6.5.1.1.(2) |
CSA | C282 |
Alimentation électrique de secours des bâtiments | CNB 3.2.7.5. 1) CNPI 6.5.1.1. 1) CNPI 6.5.1.4. 1) CNPI A-6.5.1.1. 2) |
CSA | C368.1:14 | Energy performance of room air conditioners | NBC Table 9.36.3.10. NECB Table 5.2.12.1.G |
CSA | C368.1:14 | Rendement énergétique des climatiseurs individuels | CNB Tableau 9.36.3.10. CNÉB Tableau 5.2.12.1.-G |
CSA | C390 |
CNÉB 7.2.4.1. 1) | |
CSA | C390: |
Test |
NECB 7.2.4.1.(1) |
CSA | C656-14 | Performance standard for split-system and single-package air conditioners and heat pumps | NBC Table 9.36.3.10. NECB Table 5.2.12.1.A NECB Table 5.2.12.1.I |
CSA | C656-14 | Norme de rendement des climatiseurs et des thermopompes à deux blocs et monoblocs | CNB Tableau 9.36.3.10. CNÉB Tableau 5.2.12.1.-A CNÉB Tableau 5.2.12.1.-I |
CSA | C748-13 | Performance of direct-expansion (DX) ground-source heat pumps | NBC Table 9.36.3.10. CNB Tableau 9.36.3.10. NECB Table 5.2.12.1.F CNÉB Tableau 5.2.12.1.-F |
CSA | C802.3-15 | Minimum efficiency values for power transformers | NECB 7.2.3.1.(1) |
CSA | C802.3-15 | Valeurs minimales de rendement pour les transformateurs de puissance | CNÉB 7.2.3.1. 1) |
CSA | C873.4-14 | Building energy estimation methodology – Part 4 – Energy consumption for lighting | NECB 4.3.1.3.(1) NECB 4.3.1.3.(2) NECB 4.3.1.3.(3) NECB 4.3.1.3.(4) NECB 4.3.1.3.(5) CNÉB 4.3.1.3. 1) CNÉB 4.3.1.3. 2) CNÉB 4.3.1.3. 3) CNÉB 4.3.1.3. 4) CNÉB 4.3.1.3. 5) |
CSA | F280-12 | Determining the required capacity of residential space heating and cooling appliances | NBC 9.33.5.1.(1) NBC A-9.36.3.2.(1) NBC A-9.36.5.15.(5) |
CSA | F280-12 | Détermination de la puissance requise des appareils de chauffage et de refroidissement résidentiels | CNB 9.33.5.1. 1) CNB A-9.36.3.2. 1) CNB A-9.36.5.15. 5) |
CSA | G30.18-09 | Carbon steel bars for concrete reinforcement | NBC 9.3.1.1.(4) |
CSA | G30.18-09 | Barres d'acier au carbone pour l'armature du béton | CNB 9.3.1.1. 4) |
CSA | G40.21-13 | Structural quality steel | NBC 4.2.3.8.(1) NBC 9.23.4.3.(2) NBC Table 5.9.1.1. |
CSA | G40.21-13 | Acier de construction | CNB 4.2.3.8. 1) CNB 9.23.4.3. 2) CNB Tableau 5.9.1.1. |
CSA | O112.10-08 | Evaluation of Adhesives for Structural Wood Products (Limited Moisture Exposure) | NBC D-2.3.6. NBC Table 9.10.3.1.-B CNB D-2.3.6. CNB Tableau 9.10.3.1.-B |
CSA | O112.9:10 | Evaluation of adhesives for structural wood products (exterior exposure) | NBC Table 9.10.3.1.-B CNB Tableau 9.10.3.1.-B |
CSA | O118.1-08 | Western Red Cedar Shakes and Shingles | NBC 9.27.7.1.(1) NBC Table 5.9.1.1. NBC Table 9.26.2.1.B |
CSA | O118.1-08 | Bardeaux et bardeaux de fente en thuya géant | CNB 9.27.7.1. 1) CNB Tableau 5.9.1.1. CNB Tableau 9.26.2.1.B |
CSA | O118.2-08 | Eastern White Cedar Shingles | NBC 9.27.7.1.(1) NBC Table 5.9.1.1. NBC Table 9.26.2.1.B |
CSA | O118.2-08 | Bardeaux en thuya occidental | CNB 9.27.7.1. 1) CNB Tableau 5.9.1.1. CNB Tableau 9.26.2.1.B |
CSA | O121-17 | Douglas fir plywood | NBC 9.23.15.2.(1) NBC 9.23.16.2.(1) NBC 9.27.8.1.(1) NBC 9.30.2.2.(1) NBC D-3.1.1. NBC Table 5.9.1.1. NBC Table 9.23.12.3.-A NBC Table 9.23.12.3.-B NBC Table 9.23.12.3.-C NBC Table 9.23.17.2.A |
CSA | O121-17 | Contreplaqué en sapin de Douglas | CNB 9.23.15.2. 1) CNB 9.23.16.2. 1) CNB 9.27.8.1. 1) CNB 9.30.2.2. 1) CNB D-3.1.1. CNB Tableau 5.9.1.1. CNB Tableau 9.23.12.3.-A CNB Tableau 9.23.12.3.-B CNB Tableau 9.23.12.3.-C CNB Tableau 9.23.17.2.A |
CSA | O141:05 | Softwood Lumber | NBC 9.3.2.6.(1) NBC A-9.3.2.1.(1) NBC D-2.3.6. NBC D-2.4.1. NBC Table 5.9.1.1. CNB 9.3.2.6. 1) CNB A-9.3.2.1. 1) CNB D-2.3.6. CNB D-2.4.1. CNB Tableau 5.9.1.1. |
CSA | O151-17 | Canadian softwood plywood | NBC 9.23.15.2.(1) NBC 9.23.16.2.(1) NBC 9.27.8.1.(1) NBC 9.30.2.2.(1) NBC D-3.1.1. NBC Table 5.9.1.1. NBC Table 9.23.12.3.-A NBC Table 9.23.12.3.-B NBC Table 9.23.12.3.-C NBC Table 9.23.17.2.A |
CSA | O151-17 | Contreplaqué en bois de résineux canadien | CNB 9.23.15.2. 1) CNB 9.23.16.2. 1) CNB 9.27.8.1. 1) CNB 9.30.2.2. 1) CNB D-3.1.1. CNB Tableau 5.9.1.1. CNB Tableau 9.23.12.3.-A CNB Tableau 9.23.12.3.-B CNB Tableau 9.23.12.3.-C CNB Tableau 9.23.17.2.A |
CSA | O153-13 | Poplar plywood | NBC 9.23.15.2.(1) NBC 9.23.16.2.(1) NBC 9.27.8.1.(1) NBC 9.30.2.2.(1) NBC D-3.1.1. NBC Table 5.9.1.1. NBC Table 9.23.17.2.A |
CSA | O153-13 | Contreplaqué en peuplier | CNB 9.23.15.2. 1) CNB 9.23.16.2. 1) CNB 9.27.8.1. 1) CNB 9.30.2.2. 1) CNB D-3.1.1. CNB Tableau 5.9.1.1. CNB Tableau 9.23.17.2.A |
CSA | O177-06 | Qualification Code for Manufacturers of Structural Glued-Laminated Timber | NBC 4.3.1.2.(1) NBC Table 9.23.12.3.-D NBC Table 9.23.4.2.-K |
CSA | O177-06 | Règles de qualification des fabricants de bois de charpente lamellé-collé | CNB 4.3.1.2. 1) CNB Tableau 9.23.12.3.-D CNB Tableau 9.23.4.2.-K |
CSA | O325-16 | Construction sheathing | NBC 9.23.15.2.(1) NBC 9.23.15.4.(2) NBC 9.23.16.2.(1) NBC 9.23.16.3.(2) NBC 9.29.9.1.(2) NBC 9.29.9.2.(5) NBC D-3.1.1. NBC Table 5.9.1.1. NBC Table 9.23.12.3.-A NBC Table 9.23.12.3.-B NBC Table 9.23.12.3.-C NBC Table 9.23.13.6. |
CSA | O325-16 | Revêtements intermédiaires de construction | CNB 9.23.15.2. 1) CNB 9.23.15.4. 2) CNB 9.23.16.2. 1) CNB 9.23.16.3. 2) CNB 9.29.9.1. 2) CNB 9.29.9.2. 5) CNB D-3.1.1. CNB Tableau 5.9.1.1. CNB Tableau 9.23.12.3.-A CNB Tableau 9.23.12.3.-B CNB Tableau 9.23.12.3.-C CNB Tableau 9.23.13.6. |
CSA | O437.0-93 | OSB and Waferboard | NBC 9.23.15.2.(1) NBC 9.23.15.4.(2) NBC 9.23.16.2.(1) NBC 9.23.16.3.(2) NBC 9.27.10.1.(1) NBC 9.29.9.1.(2) NBC 9.30.2.2.(1) NBC A-9.23.15.4.(2) NBC D-3.1.1. NBC Table 5.9.1.1. NBC Table 9.23.12.3.-A NBC Table 9.23.12.3.-B NBC Table 9.23.12.3.-C NBC Table 9.23.17.2.A |
CSA | O437.0-93 | Panneaux de particules orientées et panneaux de grandes particules | CNB 9.23.15.2. 1) CNB 9.23.15.4. 2) CNB 9.23.16.2. 1) CNB 9.23.16.3. 2) CNB 9.27.10.1. 1) CNB 9.29.9.1. 2) CNB 9.30.2.2. 1) CNB A-9.23.15.4. 2) CNB D-3.1.1. CNB Tableau 5.9.1.1. CNB Tableau 9.23.12.3.-A CNB Tableau 9.23.12.3.-B CNB Tableau 9.23.12.3.-C CNB Tableau 9.23.17.2.A |
CSA | O86: |
Engineering design in wood | NBC 4.3.1.1.(1) NBC A-5.1.4.1.(6)(b) and (c) NBC A-9.15.2.4.(1) NBC A-9.23.4.2. NBC D-2.11.3. NBC D-2.11.4. NBC Table 4.1.8.9. |
CSA | O86: |
CNB 4.3.1.1. 1) CNB A-5.1.4.1. 6)b) et c) CNB A-9.15.2.4. 1) CNB A-9.23.4.2. CNB D-2.11.3. CNB D-2.11.4. CNB Tableau 4.1.8.9. |
|
CSA | PLUS 2203 (3rd. ed. pub. 2001) | Hazardous Locations: A Guide for the Design, Testing, Construction, and Installation of Equipment in Explosive Atmospheres | NFC A-4.1.4.1.(1) CNPI A-4.1.4.1. 1) |
CSA | P.10-07 | Performance of Integrated Mechanical Systems for Residential Heating and Ventilation | NBC 9.36.3.9.(2) NBC Table 9.36.3.10. NBC Table 9.36.4.2. NBC Table 9.36.5.15.C CNB 9.36.3.9. 2) CNB Tableau 9.36.3.10. CNB Tableau 9.36.4.2. CNB Tableau 9.36.5.15.C |
CSA | P.6-09 | Test method for measuring thermal efficiency of gas-fired pool heaters | NBC Table 9.36.4.2. CNB Tableau 9.36.4.2. NECB Table 6.2.2.1. CNÉB Tableau 6.2.2.1. |
North American |
NBC 4.1.8.1.(5) NBC 4.3.4.2.(1) NBC Table 4.1.8.9. |
||
CNB 4.1.8.1. 5) CNB 4.3.4.2. 1) CNB Tableau 4.1.8.9. |
|||
CSA | S157-17/S157.1-17 | Strength design in aluminum/Commentary on CSA S157-17, Strength design in aluminum | NBC 4.3.5.1.(1) |
CSA | S157-17/S157.1-17 | Calcul de la résistance mécanique des éléments en aluminium/Commentaire sur la CSA S157-17, Calcul de la résistance mécanique des éléments en aluminium | CNB 4.3.5.1. 1) |
CSA | S16: |
Design and construction of steel structures | NBC 4.3.4.1.(1) NBC A-4.1.5.11. NBC A-4.3.4.1.(1) NBC A-Table 4.1.8.9. NBC D-2.6.6. NBC Table 4.1.8.9. |
CSA | S16: |
CNB 4.3.4.1. 1) CNB A-4.1.5.11. CNB A-4.3.4.1. 1) CNB A-Tableau 4.1.8.9. CNB D-2.6.6. CNB Tableau 4.1.8.9. |
|
CSA | S269.1-16 | Falsework and formwork | NBC 4.1.1.3.(4) NBC A-9.15.1.1.(1)(c) and 9.20.1.1.(1)(b) |
CSA | S269.1-16 | Ouvrages provisoires et coffrages | CNB 4.1.1.3. 4) CNB A-9.15.1.1. 1)c) et 9.20.1.1. 1)b) |
CSA | S269.2-16 | Access scaffolding for construction purposes | NBC 4.1.1.3.(4) |
CSA | S269.2-16 | Échafaudages d'accès pour les travaux de construction | CNB 4.1.1.3. 4) |
CSA | S304 |
Design of masonry structures | NBC 4.3.2.1.(1) NBC A-5.1.4.1.(6)(b) and (c) NBC Table 4.1.8.9. |
CSA | S304 |
Calcul des ouvrages en maçonnerie | CNB 4.3.2.1. 1) CNB A-5.1.4.1. 6)b) et c) CNB Tableau 4.1.8.9. |
CSA | S367-12 | Air-, cable-, and frame-supported membrane structures | NBC 4.4.1.1.(1) CNB 4.4.1.1. 1) |
CSA | S406-16 | Specification of permanent wood foundations for housing and small buildings | NBC 9.15.2.4.(1) NBC 9.16.5.1.(1) NBC A-9.15.2.4.(1) |
CSA | S406-16 | Spécification visant les fondations permanentes en bois pour les maisons et petits bâtiments | CNB 9.15.2.4. 1) CNB 9.16.5.1. 1) CNB A-9.15.2.4. 1) |
CSA | S413-14 | Parking structures | NBC 4.4.2.1.(1) NBC A-4.4.2.1.(1) |
CSA | S413-14 | Parking structures | CNB 4.4.2.1. 1) CNB A-4.4.2.1. 1) |
CSA | S478:19 | Durability in buildings | NBC A-5.1.4.2. |
CSA | S478:19 | Durabilité des bâtiments | CNB A-5.1.4.2. |
CSA | S6 |
Canadian Highway Bridge Design Code | NBC A-Table 4.1.5.3. NBC A-Table 4.1.5.9. |
CSA | S6 |
Code canadien sur le calcul des ponts routiers | CNB A-Tableau 4.1.5.3. CNB A-Tableau 4.1.5.9. |
CSA | S832:14 | Seismic risk reduction of operational and functional components (OFCs) of buildings | NBC A-Table 4.1.8.18. |
CSA | S832:14 | Réduction du risque sismique associé à la défaillance des composants fonctionnels et opérationnels des bâtiments (CFO) dans les bâtiments | CNB A-Tableau 4.1.8.18. |
CSA | W117.2:19 | Safety in welding, cutting and allied processes | NFC 5.2.1.1.(2) |
CSA | W117.2:19 | Règles de sécurité en soudage, coupage et procédés connexes | CNPI 5.2.1.1. 2) |
CSA | Z240 MH Series-16 | Manufactured homes | NBC A-1.1.1.1.(2) of Division A |
CSA | Z240 MM Série-16 | Maisons usinées | CNB A-1.1.1.1. 2) de la division A |
CSA | Z240.10.1:19 | Site preparation, foundation, and installation of buildings | NBC 9.15.1.3.(1) NBC 9.23.6.3.(1) NBC A-1.1.1.1.(2) of Division A |
CSA | Z240.10.1:19 | Aménagement du terrain, construction des fondations et installation de bâtiments | CNB 9.15.1.3. 1) CNB 9.23.6.3. 1) CNB A-1.1.1.1. 2) de la division A |
CSA | Z240.2.1-16 | Structural requirements for manufactured homes | NBC 9.12.2.2.(6) NBC 9.15.1.3.(1) NBC A-1.1.1.1.(2) of Division A |
CSA | Z240.2.1-16 | Exigences techniques relatives aux maisons usinées | CNB 9.12.2.2. 6) CNB 9.15.1.3. 1) CNB A-1.1.1.1. 2) de la division A |
CSA | Z245.1 |
Steel pipe | NFC 4.5.2.1.(4) CNPI 4.5.2.1. 4) |
CSA | Z32-15 | Electrical safety and essential electrical systems in health care facilities | NBC 3.2.7.3.(4) NBC 3.2.7.6.(1) NBC A-3.2.7.6.(1) NFC 6.5.1.1.(2) NFC A-6.5.1.1.(2) |
CSA | Z32-15 | Sécurité en matière d'électricité et réseaux électriques essentiels des établissements de santé | CNB 3.2.7.3. 4) CNB 3.2.7.6. 1) CNB A-3.2.7.6. 1) CNPI 6.5.1.1. 2) CNPI A-6.5.1.1. 2) |
CSA | Z7396.1-17 | Medical gas pipeline systems – Part 1: Pipelines for medical gases, medical vacuum, medical support gases, and anaesthetic gas scavenging systems | NBC 3.7.3.1.(1) |
CSA | Z7396.1-17 | Réseaux de distribution de gaz médicaux – Partie 1 : Canalisations pour les gaz médicaux, l'aspiration médicale, les gaz de soutien médical et les systèmes d'évacuation des gaz d'anesthésie | CNB 3.7.3.1. 1) |
CSA | 6.19-01 | Residential carbon monoxide alarming devices | NBC 6.9.3.1.(2) NBC 9.32.3.9.(2) NBC 9.32.3.9.(3) CNB 6.9.3.1. 2) CNB 9.32.3.9. 2) CNB 9.32.3.9. 3) |
CSA/ICC | CSA B805-18/ICC 805-2018 | Rainwater harvesting systems | NPC 2.7.2.4.(4) NPC A-2.7.2.4.(1) |
CSA/ICC | CSA B805-18/ICC 805-2018 | Systèmes de récupération d'eau de pluie | CNP 2.7.2.4. 4) CNP A-2.7.2.4. 1) |
CSSBI | 23M-2016 | Standard for Residential Steel Cladding | NBC 9.27.11.1.(1) NBC A-9.27.11.1.(1) |
ICTAB | 23M-2016 | Norme pour le bardage résidentiel en acier | CNB 9.27.11.1. 1) CNB A-9.27.11.1. 1) |
CTI | ATC-105DS-18 | Acceptance Test Code for Dry Fluid Coolers | NECB Table 5.2.12.2. CNÉB Tableau 5.2.12.2. |
CTI | ATC-105S-11 | Acceptance Test Code for Closed Circuit Cooling Towers | NECB Table 5.2.12.2. CNÉB Tableau 5.2.12.2. |
CTI | ATC-105-00 | Acceptance Test Code | NECB Table 5.2.12.2. CNÉB Tableau 5.2.12.2. |
CTI | ATC-106-11 | Acceptance Test Code for Mechanical Draft Evaporative Vapor Condensers | NECB Table 5.2.12.2. CNÉB Tableau 5.2.12.2. |
CTI | STD-201RS-04 | Standard for the Certification of Water Cooling Tower Thermal Performance | NECB Table 5.2.12.2. CNÉB Tableau 5.2.12.2. |
CWC | 1997 | Introduction to Wood Building Technology | NBC A-9.27.3.8.(4) |
CCB | 1997 | Introduction to Wood Building Technology | CNB A-9.27.3.8. 4) |
CWC | 2000 | Wood Reference Handbook | NBC A-9.27.3.8.(4) |
CCB | 2000 | Manuel de la construction en bois | CNB A-9.27.3.8. 4) |
CWC | 2009 | The Span Book | NBC A-9.23.4.2. |
CCB | 2009 | Le livre des portées | CNB A-9.23.4.2. |
CWC | 2014 | Engineering Guide for Wood Frame Construction | NBC 9.23.13.1.(2) NBC 9.23.13.2.(2) NBC 9.23.13.3.(2) NBC 9.4.1.1.(1) NBC A-9.23.13.1. NBC A-9.4.1.1. |
CCB | 2014 | Engineering Guide for Wood Frame Construction | CNB 9.23.13.1. 2) CNB 9.23.13.2. 2) CNB 9.23.13.3. 2) CNB 9.4.1.1. 1) CNB A-9.23.13.1. CNB A-9.4.1.1. |
DASMA | ANSI/DASMA 105-2017 | Test Method for Thermal Transmittance and Air Infiltration of Garage Doors | NECB 3.2.4.3.(8) CNÉB 3.2.4.3. 8) |
DIN | EN 303-5:2012 | Heating boilers – Part 5: Heating boilers for solid fuels, manually and automatically stoked, nominal heat output of up to 500 kW – Terminology, requirements, testing and marking; German version EN 303-5:2012 | NBC Table 9.36.3.10. CNB Tableau 9.36.3.10. NECB Table 5.2.12.1.P CNÉB Tableau 5.2.12.1.-P |
DIN | EN 416:2019 | Gas-fired overhead radiant tube heaters and radiant tube heater systems for non-domestic use – Safety and energy efficiency; German version EN 416:2019 | NECB Table 5.2.12.1.P CNÉB Tableau 5.2.12.1.-P |
DIN | EN 419:2019 | Gas-fired overhead luminous radiant heaters for non-domestic use – Safety and energy efficiency; German version EN 419:2019 | NECB Table 5.2.12.1.P CNÉB Tableau 5.2.12.1.-P |
DOE | 10 CFR, Part 430-2011 | Energy, Energy Conservation Program for Consumer Products | NBC Table 9.36.4.2. CNB Tableau 9.36.4.2. |
DOE | 10 CFR, Part 430-2011 | Energy, Energy Conservation Program for Consumer Products | NECB Table 5.2.12.1.O NECB Table 6.2.2.1. CNÉB Tableau 5.2.12.1.-O CNÉB Tableau 6.2.2.1. |
DOE | 10 CFR, Part 431-2011 | Energy, Energy Efficiency Program for Certain Commercial and Industrial Equipment | NBC Table 9.36.3.10. NBC Table 9.36.4.2. CNB Tableau 9.36.3.10. CNB Tableau 9.36.4.2. NECB Table 5.2.12.1.N NECB Table 6.2.2.1. CNÉB Tableau 5.2.12.1.-N CNÉB Tableau 6.2.2.1. |
ECC | 2013 | EIFS Practice Manual | NBC A-5.9.4.1.(1) NBC A-9.27.14.1.(1) CNB A-5.9.4.1. 1) CNB A-9.27.14.1. 1) |
EPA | 40 CFR, Part 60-2008 | Protection of Environment, Standards of Performance for New Stationary Sources | NBC Table 9.36.3.10. CNB Tableau 9.36.3.10. NECB Table 5.2.12.1.P CNÉB Tableau 5.2.12.1.-P |
EPA | 510-B-93-004 | Doing Inventory Control Right for Underground Storage Tanks | NFC A-4.4.2.1.(2) CNPI A-4.4.2.1. 2) |
EPA | 510-B-95-009 | Introduction To Statistical Inventory Reconciliation For Underground Storage Tanks | NFC A-4.4.2.1.(4) CNPI A-4.4.2.1. 4) |
EPA | 530/UST-90/007 | Standard Test Procedures For Evaluating Leak Detection Methods: Statistical Inventory Reconciliation Methods | NFC A-4.4.2.1.(4) CNPI A-4.4.2.1. 4) |
EPA | 530/UST-90/008 | Standard Test Procedures For Evaluating Leak Detection Methods: Vapor-Phase Out-of-Tank Product Detectors | NFC A-4.4.2.1.(3) CNPI A-4.4.2.1. 3) |
EPA | 530/UST-90/009 | Standard Test Procedures For Evaluating Leak Detection Methods: Liquid-Phase Out-of-Tank Product Detectors | NFC A-4.4.2.1.(3) CNPI A-4.4.2.1. 3) |
EPA | 625/R-92/016 (1994) | Radon Prevention in the Design and Construction of Schools and Other Large Buildings | NBC 6.2.1.1.(1) NBC A-5.4.1.1. CNB 6.2.1.1. 1) CNB A-5.4.1.1. |
FEMA | P-750-2009 | NEHRP Recommended Seismic Provisions for New Buildings and Other Structures | NBC A-4.1.8.18.(14) and (15) CNB A-4.1.8.18. 14) et 15) |
FEMA | 450-1-2003 | NEHRP Recommended Provisions for Seismic Regulations for New Buildings and Other Structures | NBC A-4.1.8.18.(14) and (15) CNB A-4.1.8.18. 14) et 15) |
FLL | 2008 | Guidelines for the Planning, Construction and Maintenance of Green Roofing | NBC A-5.6.1.2.(2) CNB A-5.6.1.2. 2) |
FM Global | Data Sheet 7-50 (2014) | Compressed Gases in Portable Cylinders | NFC A-3.2.8.2.(2) CNPI A-3.2.8.2. 2) |
FM Global | Data Sheet 7-83 (2015) | Drainage and Containment Systems for Ignitable Liquids | NFC A-4.1.6.1.(1) CNPI A-4.1.6.1. 1) |
FPI | Project 43-10C-024 (1988) | Deflection Serviceability Criteria for Residential Floors | NBC A-9.23.4.2.(2) |
FPI | Projet 43-10C-024 (1988) | Deflection Serviceability Criteria for Residential Floors | CNB A-9.23.4.2. 2) |
SC | DORS/2001-269 | Règlement sur les produits chimiques et contenants de consommation (2001) | CNPI A-3.2.5.2. 1) |
SC | DORS/2015-17 | Règlement sur les produits dangereux | CNB 1.4.1.2. 1) de la division A CNB A-3.3.1.2. 1) CNPI 1.4.1.2. 1) de la division A CNPI 3.1.2.1. 1) CNPI 3.2.7.1. 3) CNPI 3.3.4.1. 3) CNPI A-3.2.5.2. 1) CNPI A-3.2.7.6. 3) CNPI A-4.2.2.3. 2) CNPI A-Tableau 3.2.7.1. CNPI Tableau 3.2.7.1. CNPI Tableau 3.2.7.6. |
HC | H46-2/90-156E | Exposure Guidelines for Residential Indoor Air Quality | NBC A-6.3.1.5. NBC A-9.25.5.2. |
SC | H46-2/90-156F | Directives d'exposition concernant la qualité de l'air des résidences | CNB A-6.3.1.5. CNB A-9.25.5.2. |
SC | L.C. 2002, ch. 28 | Loi sur les produits antiparasitaires | CNPI 4.2.3.2. 2) |
SC | L.R.C. (1985), ch. H-3 | Loi sur les produits dangereux | CNB A-1.4.1.2. 1) de la division A CNB A-9.25.2.2. 2) CNPI 4.2.3.2. 2) |
HC | R.S.C. 1985, c. H-3 | Hazardous Products Act | NBC A-1.4.1.2.(1) of Division A NBC A-9.25.2.2.(2) NFC 4.2.3.2.(2) |
HC | S.C. 2002, c. 28 | Pest Control Products Act | NFC 4.2.3.2.(2) |
SC | SIMDUT 1988 | Système d'information sur les matières dangereuses utilisées au travail (SIMDUT) | CNB A-1.4.1.2. 1) de la division A CNB A-3.3.1.2. 1) CNPI 3.1.2.1. 1) CNPI 3.2.7.1. 3) CNPI 3.2.7.15. 2) CNPI 3.3.4.1. 3) CNPI A-1.4.1.2. 1) de la division A CNPI A-3.2.7.1. 3) CNPI A-3.2.7.1. 3)b) CNPI A-3.2.7.13. 1) CNPI A-3.2.7.14. 1) CNPI A-3.2.7.6. 3) CNPI A-Tableau 3.2.7.1. CNPI Tableau 3.2.7.1. CNPI Tableau 3.2.7.6. |
HC | SOR/2001-269 | Consumer Chemicals and Containers Regulations, 2001 | NFC A-3.2.5.2.(1) |
HC | SOR/2015-17 | Hazardous Products Regulations | NBC 1.4.1.2.(1) of Division A NBC A-3.3.1.2.(1) NFC 1.4.1.2.(1) of Division A NFC 3.1.2.1.(1) NFC 3.2.7.1.(3) NFC 3.3.4.1.(3) NFC A-3.2.5.2.(1) NFC A-3.2.7.6.(3) NFC A-4.2.2.3.(2) NFC A-Table 3.2.7.1. NFC Table 3.2.7.1. NFC Table 3.2.7.6. |
HC | WHMIS 1988 | Workplace Hazardous Materials Information System (WHMIS) | NBC A-1.4.1.2.(1) of Division A NBC A-3.3.1.2.(1) NFC 3.1.2.1.(1) NFC 3.2.7.1.(3) NFC 3.2.7.15.(2) NFC 3.3.4.1.(3) NFC A-1.4.1.2.(1) of Division A NFC A-3.2.7.1.(3) NFC A-3.2.7.1.(3)(b) NFC A-3.2.7.13.(1) NFC A-3.2.7.14.(1) NFC A-3.2.7.6.(3) NFC A-Table 3.2.7.1. NFC Table 3.2.7.1. NFC Table 3.2.7.6. |
HC | 2004 | Fungal Contamination in Public Buildings: Health Effects and Investigation Methods | NBC A-5.5.1.1. |
SC | 2004 | Contamination fongique dans les immeubles publics : Effets sur la santé et méthodes d'évaluation | CNB A-5.5.1.1. |
HC | 2007 | Radon: A Guide for Canadian Homeowners | NBC A-5.4.1.1. NBC A-6.2.1.1. NBC A-9.13.4.3. |
SC | 2007 | Le radon : guide à l'usage des propriétaires canadiens | CNB A-5.4.1.1. CNB A-6.2.1.1. CNB A-9.13.4.3. |
HC | 2008 | Guide for Radon Measurements in Public Buildings (Schools, Hospitals, Care Facilities, Detention Centres) | NBC A-5.4.1.1. NBC A-6.2.1.1. |
HC | 2008 | Guide for Radon Measurements in Residential Dwellings (Homes) | NBC A-9.13.4.3. |
SC | 2008 | Guide sur les mesures du radon dans les édifices publics (écoles, hôpitaux, établissements de soins et centres de détention) | CNB A-5.4.1.1. CNB A-6.2.1.1. |
SC | 2008 | Guide sur les mesures du radon dans les maisons | CNB A-9.13.4.3. |
HPVA | ANSI/HPVA HP-1-2009 | American National Standard for Hardwood and Decorative Plywood | NBC 9.27.8.1.(1) NBC 9.30.2.2.(1) NBC Table 5.9.1.1. CNB 9.27.8.1. 1) CNB 9.30.2.2. 1) CNB Tableau 5.9.1.1. |
HRAI | 2017 Edition | HRAI Digest | NBC 6.2.1.1.(1) NBC 9.32.2.3.(4) NBC 9.32.3.2.(1) NBC 9.33.4.1.(1) NBC A-9.36.3.2.(1) NBC A-9.36.3.2.(2) NBC A-9.36.3.4.(1) CNB 6.2.1.1. 1) CNB 9.32.2.3. 4) CNB 9.32.3.2. 1) CNB 9.33.4.1. 1) CNB A-9.36.3.2. 1) CNB A-9.36.3.2. 2) CNB A-9.36.3.4. 1) NECB 1.1.4.2.(1) NECB A-5.2.1.1.(1) CNÉB 1.1.4.2. 1) CNÉB A-5.2.1.1. 1) |
HVI | HVI Publication 911 | Certified Home Ventilating Products Directory | NBC A-9.36.3.9.(3) CNB A-9.36.3.9. 3) NECB A-5.2.10.4.(2) CNÉB A-5.2.10.4. 2) |
HVI | HVI Publication 915-2013 | Loudness Testing and Rating Procedure | NBC 9.32.3.10.(2) NBC Table 9.32.3.10.B CNB 9.32.3.10. 2) CNB Tableau 9.32.3.10.B |
HVI | HVI Publication 916-2013 | Airflow Test Procedure | NBC 9.32.3.10.(1) CNB 9.32.3.10. 1) |
ICC | ICC 900/SRCC 300-2015 | Solar Thermal System Standard | NECB Table 6.2.2.1. CNÉB Tableau 6.2.2.1. |
ICC | 400-2012 | Standard on the Design and Construction of Log Structures | NBC 9.36.2.2.(5) NBC A-9.36.2.2.(5) CNB 9.36.2.2. 5) CNB A-9.36.2.2. 5) |
IEC | 60268-16:2011 | Sound system equipment – Part 16: Objective rating of speech intelligibility by speech transmission index | NBC A-3.2.4.22.(1)(b) CNB A-3.2.4.22. 1)b) |
IES | ANSI/IES RP-28-07 | Lighting and the Visual Environment for Senior Living | NECB A-8.4.3.2.(2) NECB Table 4.2.1.6. NECB Table 4.3.2.10.A CNÉB A-8.4.3.2. 2) CNÉB Tableau 4.2.1.6. CNÉB Tableau 4.3.2.10.A |
IES | HB-10-11 | The Lighting Handbook, 10th Edition | NECB A-Table 4.3.2.8. CNÉB A-Tableau 4.3.2.8. |
IMO | 2012 | International Maritime Dangerous Goods Code | NFC 3.3.4.8.(1) |
OMI | 2012 | Code maritime international des marchandises dangereuses | CNPI 3.3.4.8. 1) |
ISO | 10848-1:2006 | Acoustics – Laboratory measurement of the flanking transmission of airborne and impact sound between adjoining rooms – Part 1: Frame document | NBC 5.8.1.4.(2) NBC 5.8.1.4.(3) NBC 5.8.1.5.(2) NBC 5.8.1.5.(3) |
ISO | 10848-1:2006 | Acoustique – Mesurage en laboratoire des transmissions latérales du bruit aérien et des bruits de choc entre pièces adjacentes – Partie 1 : Document cadre | CNB 5.8.1.4. 2) CNB 5.8.1.4. 3) CNB 5.8.1.5. 2) CNB 5.8.1.5. 3) |
ISO | 13790:2008 | Energy performance of buildings – Calculation of energy use for space heating and cooling | NECB 1.1.4.2.(1) |
ISO | 13790:2008 | Performance énergétique des bâtiments – Calcul des besoins d'énergie pour le chauffage et le refroidissement des locaux | CNÉB 1.1.4.2. 1) |
ISO | 14683:2007 | Thermal bridges in building construction – Linear thermal transmittance – Simplified methods and default values | NECB 3.1.1.5.(5) |
ISO | 14683:2007 | Ponts thermiques dans les bâtiments – Coefficient linéique de transmission thermique – Méthodes simplifiées et valeurs par défaut | CNÉB 3.1.1.5. 5) |
ISO | 15712-1:2005 | Building acoustics - Estimation of acoustic performance of buildings from the performance of elements - Part 1: Airborne sound insulation between rooms | NBC 5.8.1.4.(1) NBC 5.8.1.4.(2) NBC 5.8.1.4.(4) NBC 5.8.1.4.(5) NBC 5.8.1.4.(6) NBC 5.8.1.5.(1) NBC 5.8.1.5.(2) NBC 5.8.1.5.(5) NBC 5.8.1.5.(6) |
ISO | 15712-1:2005 | Acoustique du bâtiment – Calcul de la performance acoustique des bâtiments à partir de la performance des éléments – Partie 1 : Isolement acoustique aux bruits aériens entre des locaux | CNB 5.8.1.4. 1) CNB 5.8.1.4. 2) CNB 5.8.1.4. 4) CNB 5.8.1.4. 5) CNB 5.8.1.4. 6) CNB 5.8.1.5. 1) CNB 5.8.1.5. 2) CNB 5.8.1.5. 5) CNB 5.8.1.5. 6) |
ISO | 3864-1:2011 | Graphical symbols – Safety colours and safety signs – Part 1: Design principles for safety signs and safety markings | NBC 3.4.5.1.(2) NBC 9.9.11.3.(2) |
ISO | 3864-1:2011 | Symboles graphiques – Couleurs de sécurité et signaux de sécurité – Partie 1 : Principes de conception pour les signaux de sécurité et les marquages de sécurité | CNB 3.4.5.1. 2) CNB 9.9.11.3. 2) |
ISO | 7010:2011 | Graphical symbols – Safety colours and safety signs – Registered safety signs | NBC 3.4.5.1.(2) NBC 9.9.11.3.(2) NBC A-3.4.5.1.(2)(c) |
ISO | 7010:2011 | Symboles graphiques – Couleurs de sécurité et signaux de sécurité – Signaux de sécurité enregistrés | CNB 3.4.5.1. 2) CNB 9.9.11.3. 2) CNB A-3.4.5.1. 2)c) |
ISO | 7240-19:2007 | Fire detection and alarm systems – Part 19: Design, installation, commissioning and service of sound systems for emergency purposes | NBC A-3.2.4.22.(1)(b) |
ISO | 7240-19:2007 | Systèmes de détection et d'alarme d'incendie – Partie 19 : Conception, installation, prise en charge et entretien des systèmes sonores pour les besoins de secours | CNB A-3.2.4.22. 1)b) |
ISO | 7731:2003 | Ergonomics – Danger signals for public and work areas – Auditory danger signals | NBC A-3.2.4.22.(1)(b) |
ISO | 7731:2003 | Ergonomie – Signaux de danger pour lieux publics et lieux de travail – Signaux de danger auditifs | CNB A-3.2.4.22. 1)b) |
ISO | 8201:1987 | Acoustics – Audible emergency evacuation signal | NBC 3.2.4.18.(2) NBC A-3.2.4.18.(2) |
ISO | 8201:1987 | Acoustique – Signal sonore d'évacuation d'urgence | CNB 3.2.4.18. 2) CNB A-3.2.4.18. 2) |
McGraw-Hill | 2009 | International Plumbing Codes Handbook | NPC A-2.6.3. CNP A-2.6.3. |
NACE | SP0169-2013 | Control of External Corrosion on Underground or Submerged Metallic Piping Systems | NFC 4.5.3.1.(1) CNPI 4.5.3.1. 1) |
NACE | SP0285-2011-SG | Corrosion Control of Underground Storage Tank Systems by Cathodic Protection | NFC 4.3.10.1.(1) CNPI 4.3.10.1. 1) |
NEMA | ANSI_ANSLG C82.11:2011 | American National Standard for Lamp Ballasts–High-Frequency Fluorescent Lamp Ballasts | NECB 4.2.1.2.(2) CNÉB 4.2.1.2. 2) |
NEMA | SB 50:2008 | Emergency Communications Audio Intelligibility Applications Guide | NBC A-3.2.4.22.(1)(b) CNB A-3.2.4.22. 1)b) |
NFPA | Édition 2010 | Fire Protection Guide to Hazardous Materials | CNB A-6.9.1.2. 1) |
NFPA | 101-2018 | Life Safety Code | NBC 3.3.2.1.(2) NBC 3.3.2.1.(3) NBC A-3.3.2.1.(2) CNB 3.3.2.1. 2) CNB 3.3.2.1. 3) CNB A-3.3.2.1. 2) |
NFPA | 10- |
Standard for Portable Fire Extinguishers | NFC 2.1.5.1.(3) NFC 6.2.1.1.(1) CNPI 2.1.5.1. 3) CNPI 6.2.1.1. 1) |
NFPA | 105- |
Standard for Smoke Door Assemblies and Other Opening Protectives | NBC 3.1.8.5.(3) NBC 3.1.8.5.(7) CNB 3.1.8.5. 3) CNB 3.1.8.5. 7) |
NFPA | 12A-2015 | Standard on Halon 1301 Fire Extinguishing Systems | NFC 2.1.3.5.(3) NFC A-2.1.3.5.(3)(c) and (d) CNPI 2.1.3.5. 3) CNPI A-2.1.3.5. 3)c) et d) |
NFPA | 12B-1990 | Standard on Halon 1211 Fire Extinguishing Systems | NFC 2.1.3.5.(3) NFC A-2.1.3.5.(3)(c) and (d) CNPI 2.1.3.5. 3) CNPI A-2.1.3.5. 3)c) et d) |
NFPA | 120-2015 | Standard for Fire Prevention and Control in Coal Mines | NFC A-5.3.1.3.(2) CNPI A-5.3.1.3. 2) |
NFPA | 12- |
Standard on Carbon Dioxide Extinguishing Systems | NFC 2.1.3.5.(3) CNPI 2.1.3.5. 3) |
NFPA | 13D- |
Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes | NBC 3.2.4.1.(2) NBC 3.2.5.12.(3) NBC 3.2.7.9.(4) NBC 9.10.18.2.(3) NBC 9.10.2.2.(2) NBC A-3.2.5.12.(2) NBC A-3.2.5.12.(6) NBC A-3.2.5.13.(1) CNB 3.2.4.1. 2) CNB 3.2.5.12. 3) CNB 3.2.7.9. 4) CNB 9.10.18.2. 3) CNB 9.10.2.2. 2) CNB A-3.2.5.12. 2) CNB A-3.2.5.12. 6) CNB A-3.2.5.13. 1) NPC 2.6.3.1.(3) CNP 2.6.3.1. 3) |
NFPA | 13R-2019 | Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies | NBC 3.2.5.12.(2) NBC A-3.2.5.12.(2) NBC A-3.2.5.12.(6) NBC A-3.2.5.13.(1) CNB 3.2.5.12. 2) CNB A-3.2.5.12. 2) CNB A-3.2.5.12. 6) CNB A-3.2.5.13. 1) |
NFPA | 13-2019 | Standard for the Installation of Sprinkler Systems | NBC 3.1.9.1.(4) NBC 3.2.4.15.(1) NBC 3.2.4.8.(2) NBC 3.2.5.12.(1) NBC 3.2.5.12.(9) NBC 3.2.8.2.(5) NBC 3.2.8.3.(2) NBC 3.3.2.14.(3) NBC 9.10.9.9.(4) NBC A-3.1.11.5.(3) and (4) NBC A-3.2.4.9.(3)(f) NBC A-3.2.5.12.(1) NBC A-3.2.5.12.(6) NBC A-3.2.5.13.(1) NBC A-3.2.8.2.(3) CNB 3.1.9.1. 4) CNB 3.2.4.15. 1) CNB 3.2.4.8. 2) CNB 3.2.5.12. 1) CNB 3.2.5.12. 9) CNB 3.2.8.2. 5) CNB 3.2.8.3. 2) CNB 3.3.2.14. 3) CNB 9.10.9.9. 4) CNB A-3.1.11.5. 3) et 4) CNB A-3.2.4.9. 3)f) CNB A-3.2.5.12. 1) CNB A-3.2.5.12. 6) CNB A-3.2.5.13. 1) CNB A-3.2.8.2. 3) NFC 3.2.1.1.(1) NFC 3.2.2.4.(3) NFC 3.2.3.3.(1) NFC 3.2.4.3.(1) NFC 3.2.6.3.(4) NFC A-2.1.3.1.(1) NFC A-3.2.1.1.(1)(a) NFC A-3.2.2.4.(3) NFC A-3.2.3.3.(2) CNPI 3.2.1.1. 1) CNPI 3.2.2.4. 3) CNPI 3.2.3.3. 1) CNPI 3.2.4.3. 1) CNPI 3.2.6.3. 4) CNPI A-2.1.3.1. 1) CNPI A-3.2.1.1. 1)a) CNPI A-3.2.2.4. 3) CNPI A-3.2.3.3. 2) |
NFPA | 14-2013 | Standard for the Installation of Standpipe and Hose Systems | NBC 3.2.5.10.(1) NBC 3.2.5.9.(1) CNB 3.2.5.10. 1) CNB 3.2.5.9. 1) |
NFPA | 15-2017 | Standard for Water Spray Fixed Systems for Fire Protection | NFC 2.1.3.5.(4) NFC 4.3.2.5.(2) NFC A-4.1.6.1.(1) CNPI 2.1.3.5. 4) CNPI 4.3.2.5. 2) CNPI A-4.1.6.1. 1) |
NFPA | Standard |
NFC 2.1.3.5.(3) NFC 2.1.3.5.(4) NFC 4.3.2.5.(2) CNPI 2.1.3.5. 3) CNPI 2.1.3.5. 4) CNPI 4.3.2.5. 2) |
|
NFPA | 17A-2017 | Standard for Wet Chemical Extinguishing Systems | NFC 2.1.3.5.(3) CNPI 2.1.3.5. 3) |
NFPA | 1710-2010 | Standard for the Organization and Deployment of Fire Suppression Operations, Emergency Medical Operations, and Special Operations to the Public by Career Fire Departments | NBC A-3.2.3.1.(8) CNB A-3.2.3.1. 8) |
NFPA | 17-2017 | Standard for Dry Chemical Extinguishing Systems | NFC 2.1.3.5.(3) CNPI 2.1.3.5. 3) |
NFPA | 18-2017 | Standard on Wetting Agents | NFC 2.1.3.5.(5) CNPI 2.1.3.5. 5) |
NFPA | 2008 | Fire Protection Handbook, Twentieth Edition | NBC A-3.2.2.2.(1) NBC A-3.6.2.7.(5) NFC A-2.4.1.3.(1) |
NFPA | 2008 | Fire Protection Handbook, Twentieth Edition | CNB A-3.2.2.2. 1) CNB A-3.6.2.7. 5) CNPI A-2.4.1.3. 1) |
NFPA | 2010 Edition | Fire Protection Guide to Hazardous Materials | NBC A-6.9.1.2.(1) |
NFPA | 20- |
Standard for the Installation of Stationary Pumps for Fire Protection | NBC 3.2.4.9.(4) NBC 3.2.5.18.(1) NBC A-3.2.4.9.(3)(f) CNB 3.2.4.9. 4) CNB 3.2.5.18. 1) CNB A-3.2.4.9. 3)f) |
NFPA | 204-2018 | Standard for Smoke and Heat Venting | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) |
NFPA | 211-2019 | Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances | NBC 6.3.3.2.(2) NBC 6.3.3.3.(1) CNB 6.3.3.2. 2) CNB 6.3.3.3. 1) |
NFPA | 25-2017 | Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems | NFC 6.4.1.1.(1) CNPI 6.4.1.1. 1) |
NFPA | 30A-2018 | Code for Motor Fuel Dispensing Facilities and Repair Garages | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) |
NFPA | 30B-2019 | Code for the Manufacture and Storage of Aerosol Products | NFC 3.2.5.2.(1) NFC 3.2.5.5.(1) NFC A-3.2.5.2.(1) CNPI 3.2.5.2. 1) CNPI 3.2.5.5. 1) CNPI A-3.2.5.2. 1) |
NFPA | 30- |
Flammable and Combustible Liquids Code | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) NFC 4.2.7.6.(1) NFC A-4.1.1.1.(2) NFC A-4.1.4.1.(1) NFC A-4.1.6.1.(1) NFC A-4.2.7.6.(1) NFC A-4.3.16.1.(1) CNPI 4.2.7.6. 1) CNPI A-4.1.1.1. 2) CNPI A-4.1.4.1. 1) CNPI A-4.1.6.1. 1) CNPI A-4.2.7.6. 1) CNPI A-4.3.16.1. 1) |
NFPA | 303-2016 | Fire Protection Standard for Marinas and Boatyards | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) |
NFPA | 307-2016 | Standard for the Construction and Fire Protection of Marine Terminals, Piers, and Wharves | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) |
NFPA | 32-2016 | Standard for Drycleaning Facilities | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) NFC 5.4.2.1.(1) CNPI 5.4.2.1. 1) |
NFPA | 326-2020 | Standard for the Safeguarding of Tanks and Containers for Entry, Cleaning, or Repair | NFC A-5.6.1.11.(4) CNPI A-5.6.1.11. 4) |
NFPA | 33- |
Standard for Spray Application Using Flammable or Combustible Materials | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) NFC 5.4.5.2.(1) CNPI 5.4.5.2. 1) |
NFPA | 34-2018 | Standard for Dipping, Coating, and Printing Processes Using Flammable or Combustible Liquids | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) NFC 5.4.6.2.(1) CNPI 5.4.6.2. 1) |
NFPA | 35-2016 | Standard for Manufacture of Organic Coatings | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) |
NFPA | 36-2017 | Standard for Solvent Extraction Plants | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) NFC A-4.1.1.1.(2) CNPI A-4.1.1.1. 2) |
NFPA | 37- |
Standard for the Installation and Use of Stationary Combustion Engines and Gas Turbines | NFC 4.3.13.2.(1) CNPI 4.3.13.2. 1) |
NFPA | 40-2019 | Standard for the Storage and Handling of Cellulose Nitrate Film | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) |
NFPA | 409-2016 | Standard on Aircraft Hangars | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) |
NFPA | 415-2016 | Standard on Airport Terminal Buildings, Fueling Ramp Drainage, and Loading Walkways | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) |
NFPA | 484-2019 | Standard for Combustible Metals | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) NFC A-5.3.1.3.(2) CNPI A-5.3.1.3. 2) |
NFPA | 497-2017 | Recommended Practice for the Classification of Flammable Liquids, Gases, or Vapors and of Hazardous (Classified) Locations for Electrical Installations in Chemical Process Areas | NFC A-4.1.4.1.(1) CNPI A-4.1.4.1. 1) |
NFPA | 505-2018 | Fire Safety Standard for Powered Industrial Trucks Including Type Designations, Areas of Use, Conversions, Maintenance, and Operations | NFC 3.1.3.1.(1) CNPI 3.1.3.1. 1) |
NFPA | 51A-2012 | Standard for Acetylene Cylinder Charging Plants | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) |
NFPA | 51-2018 | Standard for the Design and Installation of Oxygen-Fuel Gas Systems for Welding, Cutting, and Allied Processes | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) NFC 5.2.2.4.(1) CNPI 5.2.2.4. 1) |
NFPA | 55-2020 | Compressed Gases and Cryogenic Fluids Code | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) NFC A-3.1.1.4. NFC A-5.5.5.3.(5)(b) and (7)(b) CNPI A-3.1.1.4. CNPI A-5.5.5.3. 5)b) et 7)b) |
NFPA | 61-2017 | Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) NFC A-5.3.1.3.(2) CNPI A-5.3.1.3. 2) |
NFPA | 654- |
Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) NFC A-5.3.1.3.(2) CNPI A-5.3.1.3. 2) |
NFPA | 655-2017 | Standard for Prevention of Sulfur Fires and Explosions | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) NFC A-5.3.1.3.(2) CNPI A-5.3.1.3. 2) |
NFPA | 664-2017 | Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) NFC 5.3.2.1.(1) NFC A-5.3.1.3.(2) CNPI 5.3.2.1. 1) CNPI A-5.3.1.3. 2) |
NFPA | 68- |
Standard on Explosion Protection by Deflagration Venting | NBC 3.3.6.4.(2) NBC A-3.6.2.7.(5) NBC A-6.9.1.2.(1) CNB 3.3.6.4. 2) CNB A-3.6.2.7. 5) CNB A-6.9.1.2. 1) NFC 3.2.8.2.(1) NFC 4.3.14.3.(1) NFC 4.9.3.1.(1) NFC 4.9.4.2.(1) NFC 5.3.1.6.(2) CNPI 3.2.8.2. 1) CNPI 4.3.14.3. 1) CNPI 4.9.3.1. 1) CNPI 4.9.4.2. 1) CNPI 5.3.1.6. 2) |
NFPA | 69- |
Standard on Explosion Prevention Systems | NBC A-3.6.2.7.(5) NBC A-6.9.1.2.(1) CNB A-3.6.2.7. 5) CNB A-6.9.1.2. 1) NFC 4.3.2.5.(2) NFC 4.9.4.2.(1) NFC 5.3.1.7.(2) CNPI 4.3.2.5. 2) CNPI 4.9.4.2. 1) CNPI 5.3.1.7. 2) |
NFPA | 705-2018 | Recommended Practice for a Field Flame Test for Textiles and Films | NFC 2.3.2.2.(1) NFC 2.9.2.1.(1) NFC A-2.3.2.2.(1) CNPI 2.3.2.2. 1) CNPI 2.9.2.1. 1) CNPI A-2.3.2.2. 1) |
NFPA | 72-2019 | National Fire Alarm and Signaling Code | NBC A-3.2.4.22.(1)(b) CNB A-3.2.4.22. 1)b) |
NFPA | 80A- |
Recommended Practice for Protection of Buildings from Exterior Fire Exposures | NBC A-3 CNB A-3 NFC A-2.4.1.1.(6) CNPI A-2.4.1.1. 6) |
NFPA | 80- |
Standard for Fire Doors and Other Opening Protectives | NBC 3.1.8.12.(2) NBC 3.1.8.16.(1) NBC 3.1.8.5.(2) NBC 3.1.9.1.(5) NBC 9.10.13.1.(1) NBC 9.10.9.9.(5) NBC A-3.1.8.1.(2) NBC A-3.2.8.2.(3) NBC D-5.2.1. CNB 3.1.8.12. 2) CNB 3.1.8.16. 1) CNB 3.1.8.5. 2) CNB 3.1.9.1. 5) CNB 9.10.13.1. 1) CNB 9.10.9.9. 5) CNB A-3.1.8.1. 2) CNB A-3.2.8.2. 3) CNB D-5.2.1. NFC 2.2.2.4.(5) CNPI 2.2.2.4. 5) |
NFPA | 82- |
Standard on Incinerators and Waste and Linen Handling Systems and Equipment | NBC 6.2.2.1.(1) NBC 9.10.10.5.(2) CNB 6.2.2.1. 1) CNB 9.10.10.5. 2) NFC 2.6.2.2.(1) CNPI 2.6.2.2. 1) |
NFPA | 85-2019 | Boiler and Combustion Systems Hazards Code | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) |
NFPA | 86-2019 | Standard for Ovens and Furnaces | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) NFC 5.4.1.2.(1) CNPI 5.4.1.2. 1) |
NFPA | 88A-2019 | Standard for Parking Structures | NBC A-6.9.1.2.(1) CNB A-6.9.1.2. 1) |
NFPA | 91-2015 | Standard for Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and Particulate Solids | NBC 6.3.4.3.(1) NBC A-6.9.1.2.(1) CNB 6.3.4.3. 1) CNB A-6.9.1.2. 1) NFC 3.2.2.3.(5) NFC 4.1.7.2.(5) NFC A-5.3.1.3.(2) CNPI 3.2.2.3. 5) CNPI 4.1.7.2. 5) CNPI A-5.3.1.3. 2) |
NFPA | 96-2014 | Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations | NBC 3.2.4.8.(2) NBC 3.6.3.5.(1) NBC 6.3.1.6.(1) NBC A-3.3.1.2.(2) NBC A-3.6.3.5. NBC A-6.9.1.2.(1) NBC A-9.10.1.4.(1) CNB 3.2.4.8. 2) CNB 3.6.3.5. 1) CNB 6.3.1.6. 1) CNB A-3.3.1.2. 2) CNB A-3.6.3.5. CNB A-6.9.1.2. 1) CNB A-9.10.1.4. 1) NFC 2.6.1.9.(2) CNPI 2.6.1.9. 2) |
NFRC | 100-2010 | Procedure for Determining Fenestration Product U-factors | NBC 9.36.2.2.(3) CNB 9.36.2.2. 3) NECB 3.1.1.5.(3) CNÉB 3.1.1.5. 3) |
NFRC | 200-2010 | Procedure for Determining Fenestration Product Solar Heat Gain Coefficient and Visible Transmittance at Normal Incidence | NBC 9.36.2.2.(3) CNB 9.36.2.2. 3) |
NIST | Building Materials and Structures Report BMS 79, 1941 | Water-Distributing Systems for Buildings | NPC A-2.6.3. CNP A-2.6.3. |
NLGA | SPS-1- |
Special Products Standard for Fingerjoined Structural Lumber | NBC A-9.23.10.4.(1) NBC Table 9.10.3.1.-A CNB A-9.23.10.4. 1) CNB Tableau 9.10.3.1.-A |
NLGA | SPS-3- |
Special Products Standard for Fingerjoined “Vertical Stud Use Only” Lumber | NBC A-9.23.10.4.(1) NBC Table 9.10.3.1.-A CNB A-9.23.10.4. 1) CNB Tableau 9.10.3.1.-A |
NLGA | Standard Grading Rules for Canadian Lumber | NBC 9.3.2.1.(1) NBC A-9.23.10.4.(1) NBC A-9.3.2.1.(1) NBC A-9.3.2.8.(1) NBC A-Table 9.3.2.1. NBC Table A-9.3.2.1.(1)A |
|
NLGA | Règles de classification pour le bois d'oeuvre canadien | CNB 9.3.2.1. 1) CNB A-9.23.10.4. 1) CNB A-9.3.2.1. 1) CNB A-9.3.2.8. 1) CNB A-Tableau 9.3.2.1. CNB Tableau A-9.3.2.1. 1)A |
|
CNRC | BPN 54F-85 | La différence entre un pare-vapeur et un pare-air | CNB A-9.25.1.1. 2) |
NRC | BPN 54-85 | The difference between a vapour barrier and an air barrier | NBC A-9.25.1.1.(2) |
NRC | CBD 222 | Airtight houses and carbon monoxide poisoning | NBC A-9.33.1.1.(2) |
NRC | CBD 230 | Applying building codes to existing buildings | NBC A-1.1.1.1.(1) of Division A |
NRC | CBD 231 | Moisture problems in houses | NBC A-9.25.3.1.(1) |
NRC | CRBCPI-Y2-R19 | Guideline on Design for Durability of Building Envelopes | NBC A-5.1.4.2. NBC A-5.4.1.1.(3) CNB A-5.1.4.2. CNB A-5.4.1.1. 3) |
CNRC | DCC 222F | Étanchéité à l'air des maisons et oxycarbonisme | CNB A-9.33.1.1. 2) |
CNRC | DCC 230F | Application des codes aux bâtiments existants | CNB A-1.1.1.1. 1) de la division A |
CNRC | DCC 231F | Problèmes d'humidité dans les maisons | CNB A-9.25.3.1. 1) |
CNRC | NRCC 49677F-2007 | Guide des règles de l'art sur les coupe-feu et les pare-feu et leur effet sur la transmission acoustique | CNB A-9.11. |
NRC | NRCC 49677-2007 | Best Practice Guide on Fire Stops and Fire Blocks and their Impact on Sound Transmission | NBC A-9.11. |
NRC | 17808-2005 | Performance Guidelines for Basement Envelope Systems and Materials: Final Research Report | NBC A-9.25.5.1. CNB A-9.25.5.1. |
NRC | 1988 | Performance and acceptability of wood floors – Forintek studies | NBC A-9.23.4.2.(2) |
CNRC | 1988 | Performance and Acceptability of Wood Floors – Forintek Studies | CNB A-9.23.4.2. 2) |
NRC Const. | RR-331- |
Guide to Calculating Airborne Sound Transmission in Buildings | NBC A-5.8.1.4. NBC A-5.8.1.4.(4)(b) |
CNRC Const. | RR-331- |
Guide |
CNB A-5.8.1.4. CNB A-5.8.1.4. 4)b) |
NRC Const. | 2005 | A Guide for the Wind Design of Mechanically Attached Flexible Membrane Roofs | NBC A-5.2.2.2.(4) |
CNRC Const. | 2005 | Guide de conception pour contrer les effets du vent sur les couvertures à membrane souple fixées mécaniquement | CNB A-5.2.2.2. 4) |
NRCA | 3rd Edition, 2017 | The NRCA Vegetative Roof Systems Manual | NBC A-5.6.1.2.(2) CNB A-5.6.1.2. 2) |
RNCan | DORS/2016-311 | Règlement de 2016 sur l'efficacité énergétique | CNB Tableau 9.36.4.2. CNÉB 5.2.12.4. 1) CNÉB 6.2.2.4. 2) CNÉB 6.2.2.5. 1) CNÉB A-5.2.12.1. 1) et 6.2.2.1. 1) CNÉB Tableau 5.2.12.1.-A CNÉB Tableau 5.2.12.1.-B CNÉB Tableau 5.2.12.1.-C CNÉB Tableau 5.2.12.1.-D CNÉB Tableau 5.2.12.1.-E CNÉB Tableau 5.2.12.1.-G CNÉB Tableau 5.2.12.1.-I CNÉB Tableau 5.2.12.1.-K CNÉB Tableau 5.2.12.1.-N CNÉB Tableau 5.2.12.1.-O CNÉB Tableau 6.2.2.1. |
RNCan | L.C. 1992, ch. 36 | Loi sur l'efficacité énergétique | CNÉB 5.2.12.4. 1) CNÉB 6.2.2.4. 2) CNÉB 6.2.2.5. 1) CNÉB A-5.2.12.1. 1) et 6.2.2.1. 1) |
RNCan | L.R.C. (1985), ch. E-17 | Loi sur les explosifs | CNB 3.3.6.2. 3) CNPI 3.1.1.3. 1) CNPI 5.1.1.2. 1) CNPI A-3.2.9.1. 1) |
NRCan | R.S.C. 1985, c. E-17 | Explosives Act | NBC 3.3.6.2.(3) NFC 3.1.1.3.(1) NFC 5.1.1.2.(1) NFC A-3.2.9.1.(1) |
NRCan | S.C. 1992, c. 36 | Energy Efficiency Act | NECB 5.2.12.4.(1) NECB 6.2.2.4.(2) NECB 6.2.2.5.(1) NECB A-5.2.12.1.(1) and 6.2.2.1.(1) |
NRCan | SOR/2016-311 | Energy Efficiency Regulations, 2016 | NBC Table 9.36.4.2. NECB 5.2.12.4.(1) NECB 6.2.2.4.(2) NECB 6.2.2.5.(1) NECB A-5.2.12.1.(1) and 6.2.2.1.(1) NECB Table 5.2.12.1.A NECB Table 5.2.12.1.B NECB Table 5.2.12.1.C NECB Table 5.2.12.1.D NECB Table 5.2.12.1.E NECB Table 5.2.12.1.G NECB Table 5.2.12.1.I NECB Table 5.2.12.1.K NECB Table 5.2.12.1.N NECB Table 5.2.12.1.O NECB Table 6.2.2.1. |
NRCan | 2010 | Display Fireworks Manual | NFC 5.1.1.3.(1) |
RNCan | 2010 | Manuel de l'artificier | CNPI 5.1.1.3. 1) |
NSF | NSF Pro 151-8-1-95 | Health Effects from Rainwater Catchment System Components | NPC A-2.7.2.3.(2) CNP A-2.7.2.3. 2) |
NYCDH | 2008 | Guidelines on Assessment and Remediation of Fungi in Indoor Environments | NBC A-5.5.1.1. CNB A-5.5.1.1. |
OCIMF | 2009 | Guide to Manufacturing and Purchasing Hoses for Offshore Moorings, 5th Edition | NFC A-4.8.8.1.(1)(a) CNPI A-4.8.8.1. 1)a) |
OMMAH | 2012 | 2012 Building Code Compendium, Volume 2, Supplementary Standard SB-7, Guards for Housing and Small Buildings | NBC A-9.8.8.2. CNB A-9.8.8.2. |
SFPE | 4th Edition | Handbook of Fire Protection Engineering | NFC A-4.1.6.1.(1) CNPI A-4.1.6.1. 1) |
SMACNA | ANSI/SMACNA 006-2006 | HVAC Duct Construction Standards – Metal and Flexible | NBC 9.33.6.5.(2) NBC A-9.36.3.2.(2) CNB 9.33.6.5. 2) CNB A-9.36.3.2. 2) NECB 5.2.2.3.(1) NECB A-5.2.2.1.(1) NECB Table 5.2.2.3. CNÉB 5.2.2.3. 1) CNÉB A-5.2.2.1. 1) CNÉB Tableau 5.2.2.3. |
SMACNA | ANSI/SMACNA 016-2012 | HVAC Air Duct Leakage Test Manual | NECB 5.2.2.4.(1) NECB A-5.2.2.1.(1) CNÉB 5.2.2.4. 1) CNÉB A-5.2.2.1. 1) |
SMACNA | 2003 | Fibrous Glass Duct Construction Standards | NECB A-5.2.2.1.(1) CNÉB A-5.2.2.1. 1) |
SMACNA | 2006 | HVAC Systems Duct Design | NECB A-5.2.2.1.(1) CNÉB A-5.2.2.1. 1) |
SPRI | ANSI/GRHC/SPRI VR-1-2018 | Procedure for Investigating Resistance to Root or Rhizome Penetration on Vegetative Roofs | NBC 5.6.1.2.(2) CNB 5.6.1.2. 2) |
SPRI | ANSI/SPRI WD-1-2014 | Wind Design Standard Practice for Roofing Assemblies | NBC A-5.2.2.2.(4) CNB A-5.2.2.2. 4) |
STI/SPFA | SP031-2008 | Standard for Repair of Shop Fabricated Aboveground Tanks for Storage of Flammable and Combustible Liquids | NFC 4.3.1.10.(2) CNPI 4.3.1.10. 2) |
TC | DORS/2001-286 | Règlement sur le transport des marchandises dangereuses (TMD) | CNB 1.4.1.2. 1) de la division A CNB A-1.4.1.2. 1) de la division A CNB A-3.3.1.2. 1) CNPI 1.4.1.2. 1) de la division A CNPI 3.1.2.1. 1) CNPI 3.2.7.1. 3) CNPI 3.2.7.14. 1) CNPI 3.2.7.14. 4) CNPI 3.2.7.15. 2) CNPI 3.3.4.1. 3) CNPI 4.1.1.1. 3) CNPI 4.2.3.1. 1) CNPI 4.2.3.2. 2) CNPI A-1.4.1.2. 1) de la division A CNPI A-3.2.7.1. 3)b) CNPI A-3.2.7.14. 1) CNPI A-3.2.7.6. 3) CNPI A-4.1.2.1. CNPI A-4.2.2.3. 2) CNPI Tableau 3.2.7.1. CNPI Tableau 3.2.7.6. |
TC | DORS/2012-69 | Règlement sur la pollution par les bâtiments et sur les produits chimiques dangereux | CNPI A-4.8.8.1. 1)a) |
TC | DORS/82-1015 | Règlement sur la prévention des étincelles électriques sur les chemins de fer | CNPI 4.7.4.5. 2) CNPI 4.8.5.1. 1) |
TC | DORS/96-433 | Règlement de l'aviation canadien – Partie III | CNB 4.1.5.13. 1) CNPI 2.13.1.1. 1) |
TC | General Order No. 0-32, C.R.C., c. 1148 | Flammable Liquids Bulk Storage Regulations | NFC 4.5.6.5.(4) NFC 4.7.2.2.(1) NFC 4.7.4.1.(2) |
TC | Ordonnance générale n° 0-32, C.R.C., ch. 1148 | Règlement sur l'emmagasinage en vrac des liquides inflammables | CNPI 4.5.6.5. 4) CNPI 4.7.2.2. 1) CNPI 4.7.4.1. 2) |
TC | SOR/2001-286 | Transportation of Dangerous Goods Regulations (TDGR) | NBC 1.4.1.2.(1) of Division A NBC A-1.4.1.2.(1) of Division A NBC A-3.3.1.2.(1) NFC 1.4.1.2.(1) of Division A NFC 3.1.2.1.(1) NFC 3.2.7.1.(3) NFC 3.2.7.14.(1) NFC 3.2.7.14.(4) NFC 3.2.7.15.(2) NFC 3.3.4.1.(3) NFC 4.1.1.1.(3) NFC 4.2.3.1.(1) NFC 4.2.3.2.(2) NFC A-1.4.1.2.(1) of Division A NFC A-3.2.7.1.(3)(b) NFC A-3.2.7.14.(1) NFC A-3.2.7.6.(3) NFC A-4.1.2.1. NFC A-4.2.2.3.(2) NFC Table 3.2.7.1. NFC Table 3.2.7.6. |
TC | SOR/2012-69 | Vessel Pollution and Dangerous Chemicals Regulations | NFC A-4.8.8.1.(1)(a) |
TC | SOR/82-1015 | Railway Prevention of Electric Sparks Regulations | NFC 4.7.4.5.(2) NFC 4.8.5.1.(1) |
TC | SOR/96-433 | Canadian Aviation Regulations – Part III | NBC 4.1.5.13.(1) NFC 2.13.1.1.(1) |
TC | 2001 | Standards Respecting Pipeline Crossings Under Railways | NFC 4.5.6.5.(3) |
TC | 2001 | Normes concernant les canalisations traversant sous les voies ferrées | CNPI 4.5.6.5. 3) |
TIAC | 2013 | Mechanical Insulation Best Practices Guide | NBC A-6.3.2.5. NPC A-2.3.5.3. NECB A-5.2.2.5.(8) and 5.2.5.3.(7) |
ACIT | 2013 | Guide des meilleures pratiques d'isolation mécanique | CNB A-6.3.2.5. CNP A-2.3.5.3. CNÉB A-5.2.2.5. 8) et 5.2.5.3. 7) |
TPIC | Truss Design Procedures and Specifications for Light Metal Plate Connected Wood Trusses | NBC 9.23.14.11.(1) CNB 9.23.14.11. 1) |
|
TWC | 1993 | Details of Air Barrier Systems for Houses | NBC Table A-9.25.5.1.(1) CNB Tableau A-9.25.5.1. 1) |
UL | ANSI/UL 1784-2015 | Standard for Air Leakage Tests of Door Assemblies and Other Opening Protectives | NBC 3.1.8.4.(4) CNB 3.1.8.4. 4) |
ULC | ANSI/CAN/UL/ULC 2258:2018 | Standard for Aboveground Nonmetallic Tanks for Fuel Oil and Other Combustible Liquids | NFC 4.3.1.2.(1) |
ULC | ANSI/CAN/UL/ULC 2258:2018 | Norme sur les réservoirs non métalliques hors sol pour le mazout et autres liquides combustibles | CNPI 4.3.1.2. 1) |
ULC | ANSI/CAN/UL/ULC 300 |
Standard for Fire Testing of Fire Extinguishing Systems for Protection of Commercial Cooking Equipment | NBC 6.9.1.3.(1) |
ULC | ANSI/CAN/UL/ULC 300 |
Norme sur la mise à l'essai de systèmes d'extinction d'incendie conçus pour la protection d'équipement de cuisson commercial | CNB 6.9.1.3. 1) |
ULC | CAN/ULC 628:2022 | Norme sur les foyers encastrables et les poêles sur socle | CNB 9.22.10.1. 1) |
ULC | CAN/ULC |
Standard for Integrated Systems Testing of Fire Protection and Life Safety Systems | NBC 3.2.9.1.(1) NBC 9.10.1.2.(1) NBC A-3.2.9.1.(1) NFC 6.8.1.1.(1) NFC A-6.8.1.1.(1) |
ULC | CAN/ULC |
Norme sur les essais intégrés de systèmes de protection incendie et de sécurité des personnes | CNB 3.2.9.1. 1) CNB 9.10.1.2. 1) CNB A-3.2.9.1. 1) CNPI 6.8.1.1. 1) CNPI A-6.8.1.1. 1) |
ULC | CAN/ULC-S101-14 | Standard Method of Fire Endurance Tests of Building Construction and Materials | NBC 2.2.1.10.(1) NBC 2.2.1.8.(4) NBC 3.1.11.7.(1) NBC 3.1.5.14.(5) NBC 3.1.5.14.(6) NBC 3.1.5.15.(3) NBC 3.1.5.15.(4) NBC 3.1.5.7.(2) NBC 3.1.7.1.(1) NBC 3.2.3.8.(1) NBC 9.10.16.3.(1) NBC A-3.1.5.14.(5)(d) NBC D-1.1.1. NBC D-1.12.1. NBC D-2.11.1. NBC D-2.3.2. NBC Table 9.10.3.1.-B |
ULC | CAN/ULC-S101-14 | Méthodes d'essai normalisées de résistance au feu pour les bâtiments et les matériaux de construction | CNB 2.2.1.10. 1) CNB 2.2.1.8. 4) CNB 3.1.11.7. 1) CNB 3.1.5.14. 5) CNB 3.1.5.14. 6) CNB 3.1.5.15. 3) CNB 3.1.5.15. 4) CNB 3.1.5.7. 2) CNB 3.1.7.1. 1) CNB 3.2.3.8. 1) CNB 9.10.16.3. 1) CNB A-3.1.5.14. 5)d) CNB D-1.1.1. CNB D-1.12.1. CNB D-2.11.1. CNB D-2.3.2. CNB Tableau 9.10.3.1.-B |
ULC | CAN/ULC-S102-10 | Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies | NBC 3.1.12.1.(1) NBC 3.1.5.24.(1) NBC 9.29.5.2.(1) NBC D-1.1.1. NBC D-6.1.1. NBC Table 5.9.1.1. NBC Table 9.23.17.2.A |
ULC | CAN/ULC-S102-10 | Méthode d'essai normalisée caractéristiques de combustion superficielle des matériaux de construction et assemblages | CNB 3.1.12.1. 1) CNB 3.1.5.24. 1) CNB 9.29.5.2. 1) CNB D-1.1.1. CNB D-6.1.1. CNB Tableau 5.9.1.1. CNB Tableau 9.23.17.2.A |
ULC | CAN/ULC-S102.2:2018 | Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings, and Miscellaneous Materials and Assemblies | NBC 3.1.12.1.(2) NBC 3.1.13.4.(1) NBC 9.27.12.1.(4) NBC 9.27.13.1.(2) NBC D-1.1.1. NBC D-3.1.1. |
ULC | CAN/ULC-S102.2:2018 | Méthode d'essai normalisée caractéristiques de combustion superficielle des revêtements de sol et des divers matériaux et assemblages | CNB 3.1.12.1. 2) CNB 3.1.13.4. 1) CNB 9.27.12.1. 4) CNB 9.27.13.1. 2) CNB D-1.1.1. CNB D-3.1.1. |
ULC | CAN/ULC-S102.3:2018 | Standard Method of Fire Test of Light Diffusers and Lenses | NBC 3.1.13.4.(1) |
ULC | CAN/ULC-S102.3:2018 | Méthode d'essai normalisée de résistance au feu pour les diffuseurs et verres d'appareils d'éclairage | CNB 3.1.13.4. 1) |
ULC | CAN/ULC-S102.4:2017 | Standard Method of Test for Fire and Smoke Characteristics of Electrical Wiring, Cables and Non-Metallic Raceways | NBC 3.1.4.3.(2) NBC 3.1.5.21.(2) NBC 3.1.5.23.(2) |
ULC | CAN/ULC-S102.4:2017 | Méthode d'essai normalisée caractéristiques de résistance au feu et à la fumée des fils et câbles électriques et des canalisations non métalliques | CNB 3.1.4.3. 2) CNB 3.1.5.21. 2) CNB 3.1.5.23. 2) |
ULC | CAN/ULC-S104-15 | Standard Method for Fire Tests of Door Assemblies | NBC 3.1.8.4.(1) NBC 3.2.6.5.(3) |
ULC | CAN/ULC-S104-15 | Méthode normalisée des essais de résistance au feu des portes | CNB 3.1.8.4. 1) CNB 3.2.6.5. 3) |
ULC | CAN/ULC-S105:2016 | Standard Specification for Fire Door Frames Meeting the Performance Required by CAN/ULC-S104 | NBC 9.10.13.6.(1) |
ULC | CAN/ULC-S105:2016 | Norme sur les cadres de porte coupe-feu satisfaisant aux exigences de rendement de la norme CAN/ULC-S104 | CNB 9.10.13.6. 1) |
ULC | CAN/ULC-S106-15 | Standard Method for Fire Tests of Window and Glass Block Assemblies | NBC 3.1.8.4.(1) |
ULC | CAN/ULC-S106-15 | Méthode normalisée des essais de comportement au feu des fenêtres et des briques de verre | CNB 3.1.8.4. 1) |
ULC | CAN/ULC-S107:2019 | Standard Methods of Fire Tests of Roof Coverings | NBC 3.1.15.1.(1) |
ULC | CAN/ULC-S107:2019 | Méthodes normalisées d'essai de résistance au feu des matériaux de couverture | CNB 3.1.15.1. 1) |
ULC | CAN/ULC-S109-14 | Standard Method for Flame Tests of Flame-Resistant Fabrics and Films | NBC 2.2.1.14.(1) NBC 3.1.16.1.(1) NBC 3.1.18.5.(1) NBC 3.6.5.2.(2) NBC 3.6.5.3.(1) NBC 9.33.6.3.(1) NFC 2.3.2.1.(1) |
ULC | CAN/ULC-S109-14 | Méthode normalisée des essais de comportement au feu des tissus et pellicules ininflammables | CNB 2.2.1.14. 1) CNB 3.1.16.1. 1) CNB 3.1.18.5. 1) CNB 3.6.5.2. 2) CNB 3.6.5.3. 1) CNB 9.33.6.3. 1) CNPI 2.3.2.1. 1) |
ULC | CAN/ULC-S110-13 | Standard Methods of Test for Air Ducts | NBC 3.6.5.1.(2) NBC 3.6.5.1.(5) NBC 9.33.6.2.(2) NBC 9.33.6.2.(4) |
ULC | CAN/ULC-S110-13 | Méthodes normalisées d'essai des conduits d'air | CNB 3.6.5.1. 2) CNB 3.6.5.1. 5) CNB 9.33.6.2. 2) CNB 9.33.6.2. 4) |
ULC | CAN/ULC-S111-13 | Standard Method of Fire Tests for Air Filter Units | NBC 6.3.2.13.(1) NBC 9.33.6.14.(1) |
ULC | CAN/ULC-S111-13 | Méthode d'essai normalisée de résistance au feu des filtres | CNB 6.3.2.13. 1) CNB 9.33.6.14. 1) |
ULC | CAN/ULC-S112-10 | Standard Method of Fire Test of Fire Damper Assemblies | NBC 3.1.8.4.(1) NBC A-3.2.6.6.(1) |
ULC | CAN/ULC-S112-10 | Méthode d'essai normalisée de résistance au feu des registres coupe-feu | CNB 3.1.8.4. 1) CNB A-3.2.6.6. 1) |
ULC | CAN/ULC-S112.1-10 | Standard for Leakage Rated Dampers for Use in Smoke Control Systems | NBC 3.1.8.4.(3) NBC 6.3.2.7.(3) |
ULC | CAN/ULC-S112.1-10 | Norme sur les registres étanches pour systèmes de désenfumage | CNB 3.1.8.4. 3) CNB 6.3.2.7. 3) |
ULC | CAN/ULC-S112.2-07 | Standard Method of Fire Test of Ceiling Firestop Flap Assemblies | NBC 3.6.4.3.(2) NBC 9.10.13.14.(1) NBC D-2.3.10. NBC D-2.3.11. |
ULC | CAN/ULC-S112.2-07 | Méthode d'essai normalisée de comportement au feu des clapets coupe-feu situés dans les plafonds | CNB 3.6.4.3. 2) CNB 9.10.13.14. 1) CNB D-2.3.10. CNB D-2.3.11. |
ULC | CAN/ULC-S113:2016 | Standard Specification for Wood Core Doors Meeting the Performance Required by CAN/ULC-S104 for Twenty Minute Fire Rated Closure Assemblies | NBC 9.10.13.2.(1) NBC A-9.10.13.2.(1) NBC A-9.10.9.3.(2) |
ULC | CAN/ULC-S113:2016 | Spécification de norme : portes à âme de bois satisfaisant aux exigences de rendement de CAN/ULC-S104 pour les dispositifs de fermeture ayant un degré de résistance au feu de vingt minutes | CNB 9.10.13.2. 1) CNB A-9.10.13.2. 1) CNB A-9.10.9.3. 2) |
ULC | CAN/ULC-S114:2018 | Standard Method of Test for Determination of Non-Combustibility in Building Materials | NBC 1.4.1.2.(1) of Division A NBC D-1.1.1. NBC D-4.1.1. NBC D-4.2.1. NPC 1.4.1.2.(1) of Division A |
ULC | CAN/ULC-S114:2018 | Méthode d'essai normalisée pour la détermination de l'incombustibilité des matériaux de construction | CNB 1.4.1.2. 1) de la division A CNB D-1.1.1. CNB D-4.1.1. CNB D-4.2.1. CNP 1.4.1.2. 1) de la division A |
ULC | CAN/ULC-S115 |
Standard Method of Fire Tests of Firestop Systems | NBC 3.1.5.19.(3) NBC 3.1.8.3.(3) NBC 3.1.9.1.(1) NBC 3.1.9.1.(2) NBC 3.1.9.1.(3) NBC 3.1.9.1.(6) NBC 3.1.9.1.(7) NBC 3.1.9.3.(1) NBC 3.1.9.3.(2) NBC 3.1.9.3.(4) NBC 3.1.9.4.(4) NBC 3.1.9.4.(7) NBC 9.10.9.2.(3) NBC 9.10.9.6.(1) NBC 9.10.9.6.(2) NBC 9.10.9.8.(1) NBC 9.10.9.8.(6) NBC A-3.1.11.7.(7) NBC A-3.1.8.3.(2) |
ULC | CAN/ULC-S115 |
Méthode normalisée d'essais de résistance au feu des dispositifs coupe-feu | CNB 3.1.5.19. 3) CNB 3.1.8.3. 3) CNB 3.1.9.1. 1) CNB 3.1.9.1. 2) CNB 3.1.9.1. 3) CNB 3.1.9.1. 6) CNB 3.1.9.1. 7) CNB 3.1.9.3. 1) CNB 3.1.9.3. 2) CNB 3.1.9.3. 4) CNB 3.1.9.4. 4) CNB 3.1.9.4. 7) CNB 9.10.9.2. 3) CNB 9.10.9.6. 1) CNB 9.10.9.6. 2) CNB 9.10.9.8. 1) CNB 9.10.9.8. 6) CNB A-3.1.11.7. 7) CNB A-3.1.8.3. 2) |
ULC | CAN/ULC-S124 |
Standard Method of Test for the Evaluation of |
NBC 3.1.5.15.(2) NBC A-3.1.5.14.(5)(d) |
ULC | CAN/ULC-S124 |
Méthode d'essai normalisée pour l'évaluation des |
CNB 3.1.5.15. 2) CNB A-3.1.5.14. 5)d) |
ULC | CAN/ULC-S126-14 | Standard Method of Test for Fire Spread Under Roof-Deck Assemblies | NBC 3.1.14.1.(1) NBC 3.1.14.2.(1) |
ULC | CAN/ULC-S126-14 | Méthode normalisée d'essai sur la propagation des flammes sous les platelages de toits | CNB 3.1.14.1. 1) CNB 3.1.14.2. 1) |
ULC | CAN/ULC-S134-13 | Standard Method of Fire Test of Exterior Wall Assemblies | NBC 3.1.5.5.(1) NBC 9.10.14.5.(2) NBC 9.10.15.5.(2) NBC 9.10.15.5.(3) NBC D-1.1.1. NBC D-6.1.1. |
ULC | CAN/ULC-S134-13 | Méthode normalisée des essais de comportement au feu des murs extérieurs | CNB 3.1.5.5. 1) CNB 9.10.14.5. 2) CNB 9.10.15.5. 2) CNB 9.10.15.5. 3) CNB D-1.1.1. CNB D-6.1.1. |
ULC | CAN/ULC-S137:2017 | Standard Method of Test for Fire Growth of Mattresses (Open Flame Test) | NFC 2.3.2.3.(2) |
ULC | CAN/ULC-S137:2017 | Méthode d'essai normalisée pour la propagation du feu sur les matelas (essai à la flamme nue) | CNPI 2.3.2.3. 2) |
ULC | CAN/ULC-S138-06 | Standard Method of Test for Fire Growth of Insulated Building Panels in a Full-Scale Room Configuration | NBC 3.1.5.7.(1) NBC 3.1.5.7.(3) |
ULC | CAN/ULC-S138-06 | Méthode d'essai normalisée de la propagation du feu dans les panneaux de construction isolés d'une configuration de pièces à l'échelle réelle | CNB 3.1.5.7. 1) CNB 3.1.5.7. 3) |
ULC | CAN/ULC-S139:2017 | Standard for Fire Test for Circuit Integrity of Fire-Resistive Power, Instrumentation, Control and Data Cables | NBC 3.2.6.5.(6) NBC 3.2.7.10.(2) NBC 3.2.7.10.(3) |
ULC | CAN/ULC-S139:2017 | Normes sur l'essai de résistance au feu pour l'évaluation de l'intégrité des circuits des câbles d'alimentation, de l'instrumentation, des contrôles et de données | CNB 3.2.6.5. 6) CNB 3.2.7.10. 2) CNB 3.2.7.10. 3) |
ULC | CAN/ULC-S143-14 | Standard Method of Fire Tests for Non-Metallic Electrical and Optical Fibre Cable Raceway Systems | NBC 3.1.5.23.(1) |
ULC | CAN/ULC-S143-14 | Méthode d'essai normalisée de comportement au feu des systèmes de canalisation non métalliques pour câbles électriques et à fibres optiques | CNB 3.1.5.23. 1) |
ULC | CAN/ULC-S144-12 | Standard Method of Fire Resistance Test – Grease Duct Assemblies | NBC 3.6.3.5.(2) NBC A-3.6.3.5. |
ULC | CAN/ULC-S144-12 | Méthode d'essai normalisée de résistance au feu – conduits de graisse | CNB 3.6.3.5. 2) CNB A-3.6.3.5. |
ULC | CAN/ULC-S146-19 | Standard Method of Test for the Evaluation of Encapsulation Materials and Assemblies of Materials for the Protection of Structural Timber Elements | NBC 3.1.6.5.(1) |
ULC | CAN/ULC-S146-19 | Méthode d'essai normalisée pour l'évaluation des matériaux d'encapsulation et les assemblages de matériaux aux fins de la protection des éléments de bois de charpente | CNB 3.1.6.5. 1) |
ULC | CAN/ULC-S503-05 | Standard for Carbon-Dioxide Fire Extinguishers | NFC 2.1.5.1.(4) |
ULC | CAN/ULC-S503-05 | Norme sur les extincteurs au dioxyde de carbone | CNPI 2.1.5.1. 4) |
ULC | CAN/ULC-S504-12 | Standard for Dry Chemical Fire Extinguishers | NFC 2.1.5.1.(4) |
ULC | CAN/ULC-S504-12 | Norme sur les extincteurs à poudres chimiques | CNPI 2.1.5.1. 4) |
ULC | CAN/ULC-S507-05 | Standard for Water Fire Extinguishers | NFC 2.1.5.1.(4) |
ULC | CAN/ULC-S507-05 | Norme sur les extincteurs à eau | CNPI 2.1.5.1. 4) |
ULC | CAN/ULC-S508 |
Standard for the Rating and Fire Testing of Fire Extinguishers | NFC 2.1.5.1.(5) |
ULC | CAN/ULC-S508 |
CNPI 2.1.5.1. 5) | |
ULC | CAN/ULC-S512-M87 | Standard for Halogenated Agent Hand and Wheeled Fire Extinguishers | NFC 2.1.5.1.(4) |
ULC | CAN/ULC-S512-M87 | Norme sur les extincteurs à produits halogénés, à main et sur roues | CNPI 2.1.5.1. 4) |
ULC | CAN/ULC-S524:2019 | Standard for Installation of Fire Alarm Systems | NBC 3.1.8.11.(3) NBC 3.1.8.14.(3) NBC 3.2.4.20.(10) NBC 3.2.4.20.(15) NBC 3.2.4.20.(7) NBC 3.2.4.20.(8) NBC 3.2.4.5.(1) NBC 9.10.19.4.(3) NBC 9.10.19.6.(2) NBC A-3.2.4.18.(9) and (10) NBC A-3.2.4.19.(1)(g) NBC A-3.2.4.20.(10) NBC A-3.2.4.7.(4) |
ULC | CAN/ULC-S524:2019 | Norme sur l'installation des systèmes d'alarme incendie | CNB 3.1.8.11. 3) CNB 3.1.8.14. 3) CNB 3.2.4.20. 10) CNB 3.2.4.20. 15) CNB 3.2.4.20. 7) CNB 3.2.4.20. 8) CNB 3.2.4.5. 1) CNB 9.10.19.4. 3) CNB 9.10.19.6. 2) CNB A-3.2.4.18. 9) et 10) CNB A-3.2.4.19. 1)g) CNB A-3.2.4.20. 10) CNB A-3.2.4.7. 4) |
ULC | CAN/ULC-S526-2016 | Visible Signaling Devices for Fire Alarm and Signaling Systems, Including Accessories | NBC A-3.2.4.19.(3) |
ULC | CAN/ULC-S526-2016 | Appareils à signal visuel pour systèmes d'alarme incendie, y compris les accessoires | CNB A-3.2.4.19. 3) |
ULC | CAN/ULC-S531:2019 | Standard for Smoke Alarms | NBC 3.2.4.20.(2) NBC 9.10.19.1.(1) NFC 2.1.3.3.(1) |
ULC | CAN/ULC-S531:2019 | Norme sur les avertisseurs de fumée | CNB 3.2.4.20. 2) CNB 9.10.19.1. 1) CNPI 2.1.3.3. 1) |
ULC | CAN/ULC-S536:2019 | Standard for Inspection and Testing of Fire Alarm Systems | NFC 6.3.1.2.(1) |
ULC | CAN/ULC-S536:2019 | Norme sur l’inspection et la mise à l'essai des systèmes d'alarme incendie | CNPI 6.3.1.2. 1) |
ULC | CAN/ULC-S537:2019 | Standard for Verification of Fire Alarm Systems | NBC 3.2.4.5.(2) |
ULC | CAN/ULC-S537:2019 | Norme sur la vérification des systèmes d'alarme d'incendie | CNB 3.2.4.5. 2) |
ULC | CAN/ULC-S540-13 | Standard for Residential Fire and Life Safety Warning Systems: Installation, Inspection, Testing and Maintenance | NBC 3.2.4.21.(1) NBC 9.10.19.8.(1) NBC 9.10.2.2.(3) NBC 9.10.2.2.(4) NFC 6.7.1.1.(3) |
ULC | CAN/ULC-S540-13 | Norme sur les systèmes d'alarme incendie résidentiels et de sécurité des personnes : installation, inspection, mise à l'essai et entretien | CNB 3.2.4.21. 1) CNB 9.10.19.8. 1) CNB 9.10.2.2. 3) CNB 9.10.2.2. 4) CNPI 6.7.1.1. 3) |
ULC | CAN/ULC-S552-14 | Standard for Maintenance and Testing of Smoke Alarms | NFC 6.7.1.1.(1) |
ULC | CAN/ULC-S552-14 | Norme sur l'entretien et la mise à l'essai des avertisseurs de fumée | CNPI 6.7.1.1. 1) |
ULC | CAN/ULC-S553-14 | Standard for the Installation of Smoke Alarms | NBC 3.2.4.20.(13) NBC 9.10.19.3.(2) NFC 2.1.3.3.(3) |
ULC | CAN/ULC-S553-14 | Norme sur l'installation des avertisseurs de fumée | CNB 3.2.4.20. 13) CNB 9.10.19.3. 2) CNPI 2.1.3.3. 3) |
ULC | CAN/ULC-S554:2016 | Standard for Water Based Agent Fire Extinguishers | NFC 2.1.5.1.(4) |
ULC | CAN/ULC-S554:2016 | Norme sur les extincteurs à agent à base d'eau | CNPI 2.1.5.1. 4) |
ULC | CAN/ULC-S561-13 | Standard for Installation and Services for Fire Signal Receiving Centres and Systems | NBC 3.2.4.7.(4) NBC A-3.2.4.7.(4) NFC 6.3.1.3.(1) NFC A-6.3.1.3.(1) |
ULC | CAN/ULC-S561-13 | Norme sur l'installation et les services – Systèmes et centrales de réception d'alarme incendie | CNB 3.2.4.7. 4) CNB A-3.2.4.7. 4) CNPI 6.3.1.3. 1) CNPI A-6.3.1.3. 1) |
ULC | CAN/ULC-S566:2017 | Standard for Halocarbon Clean Agent Fire Extinguishers | NFC 2.1.5.1.(4) |
ULC | CAN/ULC-S566:2017 | Norme sur les extincteurs aux agents propres à l'halocarbure | CNPI 2.1.5.1. 4) |
ULC | CAN/ULC-S572:2017 | Standard for Photoluminescent and Self-Luminous Exit Signs and Path Marking Systems | NBC 3.4.5.1.(3) NBC 3.4.5.1.(4) NBC 9.9.11.3.(3) NBC 9.9.11.3.(4) NBC A-3.4.5.1.(4) |
ULC | CAN/ULC-S572:2017 | Norme sur les panneaux de signalisation d'issue et les systèmes de marquage de parcours photoluminescents et autolumineux | CNB 3.4.5.1. 3) CNB 3.4.5.1. 4) CNB 9.9.11.3. 3) CNB 9.9.11.3. 4) CNB A-3.4.5.1. 4) |
ULC | CAN/ULC-S601-14 | Standard for Shop Fabricated Steel Aboveground Tanks for Flammable and Combustible Liquids | NFC 4.3.1.2.(1) NFC 4.3.3.2.(1) |
ULC | CAN/ULC-S601-14 | Norme sur les réservoirs hors sol en acier fabriqués en usine pour liquides inflammables et combustibles | CNPI 4.3.1.2. 1) CNPI 4.3.3.2. 1) |
ULC | CAN/ULC-S602-14 | Standard for Steel Aboveground Tanks for Fuel Oil and Lubricating Oil | NFC 4.3.1.2.(1) |
ULC | CAN/ULC-S602-14 | Norme sur les réservoirs en acier non enterrés pour le mazout et l'huile lubrifiante | CNPI 4.3.1.2. 1) |
ULC | CAN/ULC-S603.1-11 | Standard for External Corrosion Protection Systems for Steel Underground Tanks for Flammable and Combustible Liquids | NFC 4.3.1.2.(1) NFC 4.3.10.1.(1) NFC 4.3.8.6.(1) NFC 4.5.3.1.(1) |
ULC | CAN/ULC-S603.1-11 | Norme sur les systèmes de protection contre la corrosion extérieure des réservoirs enterrés en acier pour les liquides inflammables et combustibles | CNPI 4.3.1.2. 1) CNPI 4.3.10.1. 1) CNPI 4.3.8.6. 1) CNPI 4.5.3.1. 1) |
ULC | CAN/ULC-S603-14 | Standard for Steel Underground Tanks for Flammable and Combustible Liquids | NFC 4.3.1.2.(1) NFC 4.4.3.2.(4) |
ULC | CAN/ULC-S603-14 | Norme sur les réservoirs souterrains en acier pour les liquides inflammables et combustibles | CNPI 4.3.1.2. 1) CNPI 4.4.3.2. 4) |
ULC | CAN/ULC-S610:2018 | Standard for Factory-Built Fireplace Systems | NBC 9.22.8.1.(1) |
ULC | CAN/ULC-S610:2018 | Norme sur les systèmes foyers à feu ouvert préfabriqué | CNB 9.22.8.1. 1) |
ULC | CAN/ULC-S612:2016 | Standard for Hose and Hose Assemblies for Flammable and Combustible Liquids | NFC 4.6.5.1.(1) |
ULC | CAN/ULC-S612:2016 | Norme sur les tuyaux flexibles et tuyaux flexibles à raccords pour liquides inflammables et combustibles | CNPI 4.6.5.1. 1) |
ULC | CAN/ULC-S615-14 | Standard for Fibre Reinforced Plastic Underground Tanks for Flammable and Combustible Liquids | NFC 4.3.1.2.(1) NFC 4.3.8.6.(2) NFC 4.4.3.2.(4) |
ULC | CAN/ULC-S615-14 | Norme sur les réservoirs en plastique renforcé souterrains pour les liquides inflammables et combustibles | CNPI 4.3.1.2. 1) CNPI 4.3.8.6. 2) CNPI 4.4.3.2. 4) |
ULC | CAN/ULC-S620:2016 | Standard for Hose Nozzle Valves for Flammable and Combustible Liquids | NFC 4.5.7.1.(2) NFC 4.6.5.2.(1) |
ULC | CAN/ULC-S620:2016 | Norme sur les pistolets pour liquides inflammables et combustibles | CNPI 4.5.7.1. 2) CNPI 4.6.5.2. 1) |
ULC | CAN/ULC-S629:2016 | Standard for 650°C Factory-Built Chimneys | NBC 9.33.10.2.(1) |
ULC | CAN/ULC-S629:2016 | Norme sur les cheminées préfabriquées pour des températures n'excédant pas 650 °C | CNB 9.33.10.2. 1) |
ULC | CAN/ULC-S633:2017 | Standard for Flexible Connector Piping for Fuels | NFC 4.5.6.14.(2) |
ULC | CAN/ULC-S633:2017 | Norme pour les tuyaux de raccordement flexibles pour carburants | CNPI 4.5.6.14. 2) |
ULC | CAN/ULC-S639-M87 | Standard for Steel Liner Assemblies for Solid-Fuel Burning Masonry Fireplaces | NBC 9.22.2.3.(1) |
ULC | CAN/ULC-S639-M87 | Norme relative aux chemisages en acier pour foyers à feu ouvert en maçonnerie à combustibles solides | CNB 9.22.2.3. 1) |
ULC | CAN/ULC-S642:2016 | Standard for Compounds and Tapes for Threaded Pipe Joints | NFC 4.5.5.1.(1) |
ULC | CAN/ULC-S642:2016 | Norme sur les composés et rubans pour joints de tuyau filetés | CNPI 4.5.5.1. 1) |
ULC | CAN/ULC-S644:2016 | Standard for Emergency Breakaway Fittings for Flammable and Combustible Liquids | NFC 4.6.5.2.(4) |
ULC | CAN/ULC-S644:2016 | Norme sur les raccords frangibles d'urgence pour liquides inflammables et combustibles | CNPI 4.6.5.2. 4) |
ULC | CAN/ULC-S651:2016 | Standard for Emergency Valves for Flammable and Combustible Liquids | NFC 4.5.7.1.(3) NFC 4.6.6.3.(1) |
ULC | CAN/ULC-S651:2016 | Norme sur les robinets d'urgence pour liquides inflammables et combustibles | CNPI 4.5.7.1. 3) CNPI 4.6.6.3. 1) |
ULC | CAN/ULC |
Standard for Tank Assemblies for the Collection, Storage and Removal of Used Oil | NFC 4.3.1.2.(1) |
ULC | CAN/ULC |
Norme sur les ensembles réservoirs destinés à la collecte, au stockage et à l'enlèvement de l'huile usagée | CNPI 4.3.1.2. 1) |
ULC | CAN/ULC |
Standard for Aboveground Horizontal Steel Contained Tank Assemblies for Flammable and Combustible Liquids | NFC 4.3.1.2.(1) |
ULC | CAN/ULC |
Norme sur les ensembles réservoirs de confinement en acier horizontaux hors sol pour les liquides inflammables et combustibles | CNPI 4.3.1.2. 1) |
ULC | CAN/ULC- |
Standard for Aboveground Protected Tank Assemblies for Flammable and Combustible Liquids | NFC 4.3.1.2.(1) NFC 4.3.2.1.(7) NFC 4.3.7.4.(2) NFC 4.6.2.1.(3) |
ULC | CAN/ULC- |
Norme sur les ensembles réservoirs protégés hors sol pour les liquides inflammables et combustibles | CNPI 4.3.1.2. 1) CNPI 4.3.2.1. 7) CNPI 4.3.7.4. 2) CNPI 4.6.2.1. 3) |
ULC | CAN/ULC-S661-10 | Standard for Overfill Protection Devices for Flammable and Combustible Liquid Storage Tanks | NFC 4.3.1.8.(1) NFC 4.3.1.8.(2) |
ULC | CAN/ULC-S661-10 | Norme sur les dispositifs de protection contre les débordements pour les réservoirs de stockage de liquides inflammables et combustibles | CNPI 4.3.1.8. 1) CNPI 4.3.1.8. 2) |
ULC | CAN/ULC-S663-11 | Standard for Spill Containment Devices for Flammable and Combustible Liquid Aboveground Storage Tanks | NFC 4.3.6.4.(4) |
ULC | CAN/ULC-S663-11 | Norme sur les dispositifs de confinement des déversements pour les réservoirs de stockage de liquides inflammables et de liquides combustibles hors sol | CNPI 4.3.6.4. 4) |
ULC | ANSI/CAN/UL/ULC |
Standard for Containment Sumps, |
NFC 4.3.9.2.(1) |
ULC | ANSI/CAN/UL/ULC |
Norme sur les puisards de |
CNPI 4.3.9.2. 1) |
ULC | CAN/ULC-S668-12 | Standard for Liners Used for Secondary Containment of Aboveground Flammable and Combustible Liquid Tanks | NFC 4.3.7.2.(2) |
ULC | CAN/ULC-S668-12 | Norme sur les membranes de confinement secondaire pour les réservoirs de stockage de liquides inflammables et de liquides combustibles hors sol | CNPI 4.3.7.2. 2) |
ULC | CAN/ULC-S669-14 | Standard for Internal Retrofit Systems for Underground Tanks for Flammable and Combustible Liquids | NFC 4.3.1.10.(3) NFC A-4.3.1.10.(3) |
ULC | CAN/ULC-S669-14 | Norme sur les systèmes de rénovation internes des réservoirs souterrains pour liquides inflammables et combustibles | CNPI 4.3.1.10. 3) CNPI A-4.3.1.10. 3) |
ULC | CAN/ULC-S675.1-14 | Standard for Volumetric Leak Detection Devices for Underground and Aboveground Storage Tanks for Flammable and Combustible Liquids | NFC A-4.4.2.1.(10)(a) NFC A-4.4.2.1.(5) NFC A-4.4.2.1.(7) |
ULC | CAN/ULC-S675.1-14 | Norme sur les dispositifs de détection volumétriques de fuite des réservoirs enterrés et non enterrés pour les liquides inflammables et les liquides combustibles | CNPI A-4.4.2.1. 10)a) CNPI A-4.4.2.1. 5) CNPI A-4.4.2.1. 7) |
ULC | CAN/ULC-S675.2-14 | Standard for Nonvolumetric Precision Leak Detection Devices for Underground and Aboveground Storage Tanks and Piping for Flammable and Combustible Liquids | NFC A-4.4.2.1.(10)(a) NFC A-4.4.2.1.(7) |
ULC | CAN/ULC-S675.2-14 | Norme sur les dispositifs de détection des fuites de précision non volumétriques pour les réservoirs de stockage et les tuyauteries, souterrains et hors sol, de liquides inflammables et combustibles | CNPI A-4.4.2.1. 10)a) CNPI A-4.4.2.1. 7) |
ULC | CAN/ULC-S676 |
Standard for Refurbishing of Storage Tanks for Flammable and Combustible Liquids | NFC 4.3.1.10.(1) |
ULC | CAN/ULC-S676 |
Norme sur la remise à neuf des réservoirs |
CNPI 4.3.1.10. 1) |
ULC | CAN/ULC |
Standard for Fire Tested Aboveground Tank Assemblies for Flammable and Combustible Liquids | NFC 4.3.1.2.(1) |
ULC | CAN/ULC |
Norme sur les ensembles réservoirs hors sol résistant au feu pour les liquides inflammables et combustibles | CNPI 4.3.1.2. 1) |
ULC | CAN/ULC-S679:2017 | Standard for Metallic and Nonmetallic Underground Piping for Flammable and Combustible Liquids | NFC 4.5.2.1.(3) NFC 4.5.6.14.(2) |
ULC | CAN/ULC-S679:2017 | Norme sur les canalisations souterraines métalliques et non métalliques pour liquides inflammables et combustibles | CNPI 4.5.2.1. 3) CNPI 4.5.6.14. 2) |
ULC | CAN/ULC-S701.1:2017 | Standard for Thermal Insulation, Polystyrene Boards | NBC 9.25.2.2.(1) NBC Table 5.9.1.1. NBC Table 9.23.17.2.A NBC Table A-9.36.2.4.(1)D |
ULC | CAN/ULC-S701.1:2017 | Norme sur l'isolant thermique en polystyrène | CNB 9.25.2.2. 1) CNB Tableau 5.9.1.1. CNB Tableau 9.23.17.2.A CNB Tableau A-9.36.2.4. 1)D |
ULC | CAN/ULC-S702.1-14 | Standard for Mineral Fibre Thermal Insulation for Buildings, Part 1: Material Specification | NBC 3.1.6.3.(4) NBC 9.10.9.8.(3) NBC 9.25.2.2.(1) NBC A-5.9.1.1.(1) NBC D-2.3.4. NBC D-2.3.5. NBC D-2.6.1. NBC D-6.1.1. NBC D-7.4. NBC Table 5.9.1.1. NBC Table 9.23.17.2.A NBC Table A-9.36.2.4.(1)D |
ULC | CAN/ULC-S702.1-14 | Norme sur l'isolant thermique de fibres minérales pour bâtiments, partie 1 : Spécifications relatives aux matériaux | CNB 3.1.6.3. 4) CNB 9.10.9.8. 3) CNB 9.25.2.2. 1) CNB A-5.9.1.1. 1) CNB D-2.3.4. CNB D-2.3.5. CNB D-2.6.1. CNB D-6.1.1. CNB D-7.4. CNB Tableau 5.9.1.1. CNB Tableau 9.23.17.2.A CNB Tableau A-9.36.2.4. 1)D |
ULC | CAN/ULC-S703-09 | Standard for Cellulose Fibre Insulation (CFI) for Buildings | NBC 9.25.2.2.(1) NBC D-2.3.4. NBC Table 5.9.1.1. NBC Table A-9.36.2.4.(1)D |
ULC | CAN/ULC-S703-09 | Norme sur l'isolant en fibre cellulosique (IFC) pour les bâtiments | CNB 9.25.2.2. 1) CNB D-2.3.4. CNB Tableau 5.9.1.1. CNB Tableau A-9.36.2.4. 1)D |
ULC | CAN/ULC- |
Standard for Thermal Insulation, Polyurethane and Polyisocyanurate, Boards, Faced | NBC 9.25.2.2.(1) NBC Table 5.9.1.1. NBC Table 9.23.17.2.A NBC Table A-9.36.2.4.(1)D |
ULC | CAN/ULC- |
Norme sur l'isolant thermique en polyuréthane et en polyisocyanurate |
CNB 9.25.2.2. 1) CNB Tableau 5.9.1.1. CNB Tableau 9.23.17.2.A CNB Tableau A-9.36.2.4. 1)D |
ULC | CAN/ULC-S705.1-18 | Standard for Thermal Insulation – Spray Applied Rigid Polyurethane Foam, Medium Density – Material Specification | NBC 9.25.2.2.(1) NBC Table 5.9.1.1. NBC Table A-9.36.2.4.(1)D |
ULC | CAN/ULC-S705.1-18 | Norme sur l'isolant thermique en mousse de polyuréthane rigide pulvérisée, de densité moyenne – spécifications relatives aux matériaux | CNB 9.25.2.2. 1) CNB Tableau 5.9.1.1. CNB Tableau A-9.36.2.4. 1)D |
ULC | CAN/ULC-S705.2 |
Standard for Thermal Insulation – Spray Applied Rigid Polyurethane Foam, Medium Density – Application | NBC 9.25.2.5.(1) NBC Table 5.9.1.1. |
ULC | CAN/ULC-S705.2 |
Norme sur l'isolant thermique en mousse de polyuréthane rigide pulvérisée, de densité moyenne – Application | CNB 9.25.2.5. 1) CNB Tableau 5.9.1.1. |
ULC | CAN/ULC-S706.1:2016 | Standard for Wood Fibre Insulating Boards for Buildings | NBC 9.23.16.7.(3) NBC 9.25.2.2.(1) NBC 9.29.8.1.(1) NBC D-3.1.1. NBC Table 5.9.1.1. NBC Table 9.23.17.2.A |
ULC | CAN/ULC-S706.1:2016 | Norme sur les panneaux isolants en fibre de bois pour bâtiments | CNB 9.23.16.7. 3) CNB 9.25.2.2. 1) CNB 9.29.8.1. 1) CNB D-3.1.1. CNB Tableau 5.9.1.1. CNB Tableau 9.23.17.2.A |
ULC | CAN/ULC-S710.1:2019 | Standard for Bead-Applied One Component Polyurethane Air Sealant Foam, Part 1: Material Specification | NBC 9.36.2.10.(6) NBC Table 5.9.1.1. |
ULC | CAN/ULC-S710.1:2019 | Norme sur la mousse d'étanchéité à l'air de polyuréthane monocomposant appliquée en cordon, partie 1 : spécifications relatives au matériau | CNB 9.36.2.10. 6) CNB Tableau 5.9.1.1. |
ULC | CAN/ULC-S711.1:2019 | Standard for Bead-Applied Two Component Polyurethane Air Sealant Foam, Part 1: Material Specification | NBC 9.36.2.10.(6) NBC Table 5.9.1.1. |
ULC | CAN/ULC-S711.1:2019 | Norme sur la mousse d'étanchéité à l'air de polyuréthane bicomposant appliquée en cordon, partie 1 : spécifications relatives au matériau | CNB 9.36.2.10. 6) CNB Tableau 5.9.1.1. |
ULC | CAN/ULC |
Standard for Thermal Insulation - Light Density, Open Cell Spray Applied Semi-Rigid Polyurethane Foam - Material Specification | NBC Table A-9.36.2.4.(1)D |
ULC | CAN/ULC |
Norme sur l'isolant thermique en mousse de polyuréthane semi-rigide pulvérisée, de faible densité et à alvéoles ouverts - spécifications relatives au matériau | CNB Tableau A-9.36.2.4. 1)D |
ULC | CAN/ULC-S716.1-12 | Standard for Exterior Insulation and Finish Systems (EIFS) - Materials and Systems | NBC 5.9.4.1.(1) NBC 9.27.14.1.(1) NBC 9.27.14.2.(1) NBC A-5.9.4.1.(1) NBC A-9.27.14.2.(2)(a) |
ULC | CAN/ULC-S716.1-12 | Norme pour les systèmes d'isolation et de finition extérieurs (Systèmes SIFE) – Matériaux et systèmes | CNB 5.9.4.1. 1) CNB 9.27.14.1. 1) CNB 9.27.14.2. 1) CNB A-5.9.4.1. 1) CNB A-9.27.14.2. 2)a) |
ULC | CAN/ULC-S716.2-12 | Standard for Exterior Insulation and Finish Systems (EIFS) - Installation of EIFS Components and Water Resistive Barrier | NBC 9.27.14.3.(1) NBC A-5.9.4.1.(1) |
ULC | CAN/ULC-S716.2-12 | Norme pour les systèmes d'isolation et de finition extérieurs (SIFE) – Installation des composants des systèmes SIFE et de la barrière résistant à l'eau | CNB 9.27.14.3. 1) CNB A-5.9.4.1. 1) |
ULC | CAN/ULC-S716.3-12 | Standard for Exterior Insulation and Finish System (EIFS) - Design Application | NBC 9.27.14.3.(1) NBC A-5.9.4.1.(1) |
ULC | CAN/ULC-S716.3-12 | Norme pour les systèmes d'isolation et de finition extérieurs (Systèmes SIFE) – Application de la conception | CNB 9.27.14.3. 1) CNB A-5.9.4.1. 1) |
ULC | CAN/ULC-S717.1: |
Standard for Flat Wall Insulating Concrete Form (ICF) Units – Material Properties | NBC 9.15.4.1.(1) NBC Table 5.9.1.1. |
ULC | CAN/ULC-S717.1: |
Norme sur les unités de coffrage à bétons isolants pour murs plats – |
CNB 9.15.4.1. 1) CNB Tableau 5.9.1.1. |
ULC | CAN/ULC-S741-08 | Standard for Air Barrier Materials – Specification | NBC 5.4.1.2.(2) NBC 9.36.2.10.(1) NECB 3.2.4.3.(2) |
ULC | CAN/ULC-S741-08 | Norme sur les matériaux d'étanchéité à l'air – Spécification | CNB 5.4.1.2. 2) CNB 9.36.2.10. 1) CNÉB 3.2.4.3. 2) |
ULC | CAN/ULC-S742-11 | Standard for Air Barrier Assemblies – Specification | NBC 5.4.1.2.(1) NBC 5.4.1.2.(2) NBC 9.36.2.9.(1) NBC A-5.4.1.1.(3) NBC A-5.4.1.2.(1) NBC A-5.4.1.2.(2) NBC A-5.4.1.2.(4) NBC A-9.36.2.10.(5)(b) NBC A-9.36.2.9.(1) NECB 3.2.4.3.(2) NECB A-3.2.4.3.(1) and (2) |
ULC | CAN/ULC-S742-11 | Norme sur les ensembles d'étanchéité à l'air – Spécification | CNB 5.4.1.2. 1) CNB 5.4.1.2. 2) CNB 9.36.2.9. 1) CNB A-5.4.1.1. 3) CNB A-5.4.1.2. 2) CNB A-5.4.1.2. 4) CNB A-5.4.1.2. 1) CNB A-9.36.2.10. 5)b) CNB A-9.36.2.9. 1) CNÉB 3.2.4.3. 2) CNÉB A-3.2.4.3. 1) et 2) |
ULC | CAN/ULC-S770-15 | Standard Test Method for Determination of Long-Term Thermal Resistance of Closed-Cell Thermal Insulating Foams | NBC Table A-9.36.2.4.(1)D |
ULC | CAN/ULC-S770-15 | Méthode d'essai normalisée pour la détermination de la résistance thermique à long terme des mousses isolantes thermiques à alvéoles fermés | CNB Tableau A-9.36.2.4. 1)D |
ULC | ULC/ORD-C107.12-92 | Line Leak Detection Devices for Flammable Liquid Piping | NFC 4.4.2.1.(11) NFC 4.4.3.4.(2) NFC 4.4.4.2.(1) CNPI 4.4.2.1. 11) CNPI 4.4.3.4. 2) CNPI 4.4.4.2. 1) |
ULC | ULC/ORD-C107.21-92 | Under-Dispenser Sumps | NFC 4.6.3.2.(1) CNPI 4.6.3.2. 1) |
ULC | ANSI/CAN/UL/ULC |
Standard for Fire Testing of |
NBC 6.9.1.3.(1) |
ULC | ANSI/CAN/UL/ULC |
CNB 6.9.1.3. 1) | |
ULC | ANSI/CAN/UL/ULC |
NFC 4.2.10.5.(1) | |
ULC | ANSI/CAN/UL/ULC |
CNPI 4.2.10.5. 1) | |
ULC | ULC/ORD-C199P-02 | Combustible Piping for Sprinkler Systems | NBC 3.2.5.13.(2) NBC 3.2.5.13.(5) CNB 3.2.5.13. 2) CNB 3.2.5.13. 5) |
ULC | ANSI/CAN/UL/ULC |
Standard for Metallic and Nonmetallic Safety |
NFC 4.1.5.8.(2) NFC 4.2.3.1.(1) NFC 4.2.6.4.(1) NFC 5.5.5.2.(2) |
ULC | ANSI/CAN/UL/ULC |
CNPI 4.1.5.8. 2) CNPI 4.2.3.1. 1) CNPI 4.2.6.4. 1) CNPI 5.5.5.2. 2) |
|
ULC | ULC/ORD-C410A-94 | Absorbents for Flammable and Combustible Liquids | NFC A-4.1.6.3.(3)(b) CNPI A-4.1.6.3. 3)b) |
ULC | ULC/ORD-C536-98 | Flexible Metallic Hose | NFC 4.5.6.14.(2) CNPI 4.5.6.14. 2) |
ULC | ULC/ORD-C558-75 | Guide for the Investigation of Internal Combustion Engine-Powered Industrial Trucks | NFC 3.1.3.1.(2) CNPI 3.1.3.1. 2) |
NFC 3.1.3.1.(3) | |||
CNPI 3.1.3.1. 3) | |||
ULC | ULC/ORD-C842-84 | Guide for the Investigation of Valves for Flammable and Combustible Liquids | NFC 4.5.7.1.(1) CNPI 4.5.7.1. 1) |
ULC | ULC-S135- |
Standard Test Method for the Determination of Combustibility Parameters of Building Materials Using an Oxygen Consumption Calorimeter (Cone Calorimeter) | NBC 3.1.5.1.(2) CNB 3.1.5.1. 2) |
ULC | ULC-S332-93 | Standard for Burglary Resisting Glazing Material | NBC A-9.7.5.2.(1) CNB A-9.7.5.2. 1) |
ULC | ULC-S505-74 | Standard for Fusible Links for Fire Protection Services | NBC 3.1.8.10.(2) CNB 3.1.8.10. 2) |
ULC | ULC-S628-93 | Standard for Fireplace Inserts | NBC 9.22.10.1.(1) |
U.S. Congress | - | National Appliance Energy Conservation Act of 1987 | NBC Table 9.36.4.2. NBC Table 9.36.5.16. CNB Tableau 9.36.4.2. CNB Tableau 9.36.5.16. |
WCLIB | No. 17 (2004) | Grading Rules for West Coast Lumber | NBC A-Table 9.3.2.1. CNB A-Tableau 9.3.2.1. |
WWPA | 2017 | Western Lumber Grading Rules 2017 | NBC A-Table 9.3.2.1. CNB A-Tableau 9.3.2.1. |